Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
A novel flexible ion-selective sensor for potassium and sodium detection was proposed. Flexible ion-selective electrodes with pseudo-liquid internal solution on contrary to the system with a solid contact provided a more stable analytical signal. Such advantages were achieved because of polyelectrolyte (PEI/PSS) layers adsorption on the conduct substrate with a layer-by-layer technique. Such an approach demonstrated that ion-selective electrodes save sensitivity with Nernstian dependence: 56.2 ± 1.4 mV/dec a Na + and 56.3 ± 1.9 mV/dec a K + , as well as a fast time of response for potassium (5 s) and sodium (8 s) was shown. The sensing platform proposed demonstrates a better time of response and is close to the Nernstian value of sensitivity with a sensor low cost. The results proposed confirm a pseudo-liquid junction for the ion-selective electrode. Biocompatibility of an ion-selective sensing platform was demonstrated at potassium potentiometric measurements in Escherichia coli biofilms. Potassium levels in a biofilm were measured with potentiometry and showed agreement with the previous results.
Переведенное название | Тонкие и гибкие ионные датчики на основе Полиэлектролитных Мультислоев Собранный на клейкую ленту углерода |
---|---|
Язык оригинала | английский |
Страницы (с-по) | 15421-15427 |
Число страниц | 7 |
Журнал | ACS Omega |
Том | 4 |
Номер выпуска | 13 |
DOI | |
Состояние | Опубликовано - 24 сен 2019 |
ID: 47515527