Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Stir flat sheet membrane liquid phase microextraction for the selective chemiluminescence determination of ofloxacin and fleroxacin in human urine. / Vakh, Christina; Likanov, Gleb; Bulatov, Andrey.
в: Microchemical Journal, Том 163, 105913, 04.2021.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Stir flat sheet membrane liquid phase microextraction for the selective chemiluminescence determination of ofloxacin and fleroxacin in human urine
AU - Vakh, Christina
AU - Likanov, Gleb
AU - Bulatov, Andrey
N1 - Publisher Copyright: © 2020 Elsevier B.V.
PY - 2021/4
Y1 - 2021/4
N2 - Stir flat sheet membrane liquid phase microextraction procedure for the chemiluminescence determination of polar antibiotics (ofloxacin and fleroxacin) in human urine samples was developed. The microextraction procedure assumed simultaneous ion-pair complex formation between antibiotic and anionic dye in acidic medium, dispersion of extraction solvent by rotation of a stir flat sheet microporous membrane unit, mass-transfer of complexes from sample into microdroplets of extraction solvent followed by extract collection into the unit. After preconcentration the unit was immersed in alkaline aqueous solution for analytes re-extraction based on ion-pair complex decomposition followed by the chemiluminescence analysis of obtained aqueous phase. The developed microextraction procedure allowed to exclude matrix effects for the selective, simple, and rapid chemiluminescence determination of ofloxacin and fleroxacin in urine samples. The calibration graphs were linear over the concentration ranges of 0.1–25 mg L−1 for ofloxacin and fleroxacin. The LOD values, calculated from the blank tests based on 3σ, were 30 µg L−1 for ofloxacin and fleroxacin. The procedure was conveniently applied to the determination of fluoroquinolones in urine samples.
AB - Stir flat sheet membrane liquid phase microextraction procedure for the chemiluminescence determination of polar antibiotics (ofloxacin and fleroxacin) in human urine samples was developed. The microextraction procedure assumed simultaneous ion-pair complex formation between antibiotic and anionic dye in acidic medium, dispersion of extraction solvent by rotation of a stir flat sheet microporous membrane unit, mass-transfer of complexes from sample into microdroplets of extraction solvent followed by extract collection into the unit. After preconcentration the unit was immersed in alkaline aqueous solution for analytes re-extraction based on ion-pair complex decomposition followed by the chemiluminescence analysis of obtained aqueous phase. The developed microextraction procedure allowed to exclude matrix effects for the selective, simple, and rapid chemiluminescence determination of ofloxacin and fleroxacin in urine samples. The calibration graphs were linear over the concentration ranges of 0.1–25 mg L−1 for ofloxacin and fleroxacin. The LOD values, calculated from the blank tests based on 3σ, were 30 µg L−1 for ofloxacin and fleroxacin. The procedure was conveniently applied to the determination of fluoroquinolones in urine samples.
KW - Chemiluminescence
KW - Fluoroquinolones
KW - Ion-pair complex
KW - Membrane-based liquid phase microextraction
KW - Stir flat sheet membrane unit
KW - Urine
KW - PHARMACEUTICALS
KW - LOMEFLOXACIN
UR - http://www.scopus.com/inward/record.url?scp=85100206931&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/d1964eac-a8b9-3578-8dd9-f526b07d2c1e/
U2 - 10.1016/j.microc.2020.105913
DO - 10.1016/j.microc.2020.105913
M3 - Article
AN - SCOPUS:85100206931
VL - 163
JO - Microchemical Journal
JF - Microchemical Journal
SN - 0026-265X
M1 - 105913
ER -
ID: 87512342