Standard

Position-sensitive MCP-based detectors with high timing resolution : some results and perspectives. / Feofilov, G. A.; Stolyarov, O. I.; Tsimbal, F. A.; Valiev, F. F.; Vinogradov, L. I.

в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 367, № 1-3, 11.12.1995, стр. 402-407.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Feofilov, GA, Stolyarov, OI, Tsimbal, FA, Valiev, FF & Vinogradov, LI 1995, 'Position-sensitive MCP-based detectors with high timing resolution: some results and perspectives', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 367, № 1-3, стр. 402-407. https://doi.org/10.1016/0168-9002(95)00751-2

APA

Feofilov, G. A., Stolyarov, O. I., Tsimbal, F. A., Valiev, F. F., & Vinogradov, L. I. (1995). Position-sensitive MCP-based detectors with high timing resolution: some results and perspectives. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 367(1-3), 402-407. https://doi.org/10.1016/0168-9002(95)00751-2

Vancouver

Feofilov GA, Stolyarov OI, Tsimbal FA, Valiev FF, Vinogradov LI. Position-sensitive MCP-based detectors with high timing resolution: some results and perspectives. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1995 Дек. 11;367(1-3):402-407. https://doi.org/10.1016/0168-9002(95)00751-2

Author

Feofilov, G. A. ; Stolyarov, O. I. ; Tsimbal, F. A. ; Valiev, F. F. ; Vinogradov, L. I. / Position-sensitive MCP-based detectors with high timing resolution : some results and perspectives. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1995 ; Том 367, № 1-3. стр. 402-407.

BibTeX

@article{8fe6fb20970643a1a56966c51b655fc7,
title = "Position-sensitive MCP-based detectors with high timing resolution: some results and perspectives",
abstract = "The microelectronic design and some results of experimental tests of three types of coordinate-sensitive Micro-Channel-Plane (MCP) based detectors with good timing properties are presented. The electrodynamic structures that could be used for the MCP fast signal readout (strips, delay lines and discrete pads) are always a compromise between the amplitude of the induced signal, propagation time delay, cross-talk and distortions of the signal at the output. In-lab tests of these structures and experimental tests of the detectors done with the beams of MIPs and with the alpha-source, have shown a 130 μm spatial resolution and a 110 ps timing resolution obtained simultaneously for one detector.",
author = "Feofilov, {G. A.} and Stolyarov, {O. I.} and Tsimbal, {F. A.} and Valiev, {F. F.} and Vinogradov, {L. I.}",
year = "1995",
month = dec,
day = "11",
doi = "10.1016/0168-9002(95)00751-2",
language = "English",
volume = "367",
pages = "402--407",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "1-3",

}

RIS

TY - JOUR

T1 - Position-sensitive MCP-based detectors with high timing resolution

T2 - some results and perspectives

AU - Feofilov, G. A.

AU - Stolyarov, O. I.

AU - Tsimbal, F. A.

AU - Valiev, F. F.

AU - Vinogradov, L. I.

PY - 1995/12/11

Y1 - 1995/12/11

N2 - The microelectronic design and some results of experimental tests of three types of coordinate-sensitive Micro-Channel-Plane (MCP) based detectors with good timing properties are presented. The electrodynamic structures that could be used for the MCP fast signal readout (strips, delay lines and discrete pads) are always a compromise between the amplitude of the induced signal, propagation time delay, cross-talk and distortions of the signal at the output. In-lab tests of these structures and experimental tests of the detectors done with the beams of MIPs and with the alpha-source, have shown a 130 μm spatial resolution and a 110 ps timing resolution obtained simultaneously for one detector.

AB - The microelectronic design and some results of experimental tests of three types of coordinate-sensitive Micro-Channel-Plane (MCP) based detectors with good timing properties are presented. The electrodynamic structures that could be used for the MCP fast signal readout (strips, delay lines and discrete pads) are always a compromise between the amplitude of the induced signal, propagation time delay, cross-talk and distortions of the signal at the output. In-lab tests of these structures and experimental tests of the detectors done with the beams of MIPs and with the alpha-source, have shown a 130 μm spatial resolution and a 110 ps timing resolution obtained simultaneously for one detector.

UR - http://www.scopus.com/inward/record.url?scp=0009136608&partnerID=8YFLogxK

U2 - 10.1016/0168-9002(95)00751-2

DO - 10.1016/0168-9002(95)00751-2

M3 - Article

AN - SCOPUS:0009136608

VL - 367

SP - 402

EP - 407

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 1-3

ER -

ID: 51039178