Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
ПЕРФУЗИОННАЯ КОМПЬЮТЕРНАЯ ТОМОГРАФИЯ В ПРЕДОПЕРАЦИОННОМ СТАДИРОВАНИИ АДЕНОКАРЦИНОМЫ ПОДЖЕЛУДОЧНОЙ ЖЕЛЕЗЫ. / Trofimova, T. N.; Belikova, M. Ya; Druzina, M. M.; Yakovleva, D. M.
в: Russian Electronic Journal of Radiology, Том 11, № 2, 2021, стр. 171-182.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - ПЕРФУЗИОННАЯ КОМПЬЮТЕРНАЯ ТОМОГРАФИЯ В ПРЕДОПЕРАЦИОННОМ СТАДИРОВАНИИ АДЕНОКАРЦИНОМЫ ПОДЖЕЛУДОЧНОЙ ЖЕЛЕЗЫ
AU - Trofimova, T. N.
AU - Belikova, M. Ya
AU - Druzina, M. M.
AU - Yakovleva, D. M.
N1 - Publisher Copyright: © 2021 Russian Electronic Journal of Radiology. All rights reserved.
PY - 2021
Y1 - 2021
N2 - Purpose. To look into the possibilities of perfusion computer tomography (PCT) in detection and preoperative staging of pancreatic adenocarcinoma, to determine and compare diagnostic effectiveness of computed tomography (CT) according to standart protocol and PCT. Materials and methods. The study included 161 patients from 28 to 96 years old (71, 8 ± 12,4 yr), who had verified pancreatic adenocarcinomas. Pancreatoduodenectomy was performed in 32 (19,8%) patients. All patients underwent CT according to standart protocol and PCT. Numerical tissue perfusion parameters of central and peripheral parts of tumors were estimated, color-coded maps were plotted and analyzed. The diagnostic effectiveness of CT according to standart protocol and PCT in preoperative staging of pancreatic adenocarcinoma were compared. Results. The diagnostic effectiveness of the perfusion program in comparison with the standard CT protocol appears to be higher in the detection and assessment of the local tumor spread, in the diagnosis of secondary lesions of regional lymph nodes. Conclusion. The perfusion program makes it possible to increase the diagnostic effiectiveness of computed tomography in the detection and assessment of the resectability of pancreatic adenocarcinoma, to determine the indications for pancreatoduodenectomy.
AB - Purpose. To look into the possibilities of perfusion computer tomography (PCT) in detection and preoperative staging of pancreatic adenocarcinoma, to determine and compare diagnostic effectiveness of computed tomography (CT) according to standart protocol and PCT. Materials and methods. The study included 161 patients from 28 to 96 years old (71, 8 ± 12,4 yr), who had verified pancreatic adenocarcinomas. Pancreatoduodenectomy was performed in 32 (19,8%) patients. All patients underwent CT according to standart protocol and PCT. Numerical tissue perfusion parameters of central and peripheral parts of tumors were estimated, color-coded maps were plotted and analyzed. The diagnostic effectiveness of CT according to standart protocol and PCT in preoperative staging of pancreatic adenocarcinoma were compared. Results. The diagnostic effectiveness of the perfusion program in comparison with the standard CT protocol appears to be higher in the detection and assessment of the local tumor spread, in the diagnosis of secondary lesions of regional lymph nodes. Conclusion. The perfusion program makes it possible to increase the diagnostic effiectiveness of computed tomography in the detection and assessment of the resectability of pancreatic adenocarcinoma, to determine the indications for pancreatoduodenectomy.
KW - Color-coded maps
KW - CT perfusion
KW - Pancreas
KW - Pancreatoduodenectomy
KW - Tissue perfusion parameters
KW - CT perfusion
KW - Color-coded maps
KW - Pancreas
KW - Pancreatoduodenectomy
KW - Tissue perfusion parameters
UR - http://www.scopus.com/inward/record.url?scp=85112086688&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/e1fdd393-0d06-35cd-9d02-85b1d8e8e2af/
U2 - 10.21569/2222-7415-2021-11-2-171-182
DO - 10.21569/2222-7415-2021-11-2-171-182
M3 - статья
AN - SCOPUS:85112086688
VL - 11
SP - 171
EP - 182
JO - Российский Электронный Журнал Лучевой Диагностики
JF - Российский Электронный Журнал Лучевой Диагностики
SN - 2222-7415
IS - 2
ER -
ID: 86422890