Standard

Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection. / Filippov, C. G.; Sokolovich, E. G.; Topolnitskii, E. B.

Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000. ed. / Andrei A. Sinebryukhov. Institute of Electrical and Electronics Engineers Inc., 2000. p. 209-211 896122 (Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000).

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

Harvard

Filippov, CG, Sokolovich, EG & Topolnitskii, EB 2000, Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection. in AA Sinebryukhov (ed.), Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000., 896122, Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000, Institute of Electrical and Electronics Engineers Inc., pp. 209-211, 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000, Tomsk, Russian Federation, 28/02/00. https://doi.org/10.1109/SPCMTT.2000.896122

APA

Filippov, C. G., Sokolovich, E. G., & Topolnitskii, E. B. (2000). Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection. In A. A. Sinebryukhov (Ed.), Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000 (pp. 209-211). [896122] (Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/SPCMTT.2000.896122

Vancouver

Filippov CG, Sokolovich EG, Topolnitskii EB. Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection. In Sinebryukhov AA, editor, Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000. Institute of Electrical and Electronics Engineers Inc. 2000. p. 209-211. 896122. (Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000). https://doi.org/10.1109/SPCMTT.2000.896122

Author

Filippov, C. G. ; Sokolovich, E. G. ; Topolnitskii, E. B. / Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection. Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000. editor / Andrei A. Sinebryukhov. Institute of Electrical and Electronics Engineers Inc., 2000. pp. 209-211 (Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000).

BibTeX

@inproceedings{276e52468820492c95b4740acff80634,
title = "Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection",
abstract = "In spite of significant successes in the field of lung surgery such complications of the post-operative period as failure of the bronchus stump and bronchial fistulas are still serious problems. According to the information of foreign and native authors the frequency of complications amounts to from 2 up to 30%. Resulting from this mortality amounts to 70%. In terms of treatment success the recovery of such patients' health therefore accounts for no more than 30%. This makes the life quality and social adaptation of patients worse. In the opinion of most authors the main cause of the presented complications is the character and quality of the bronchial suture. A large quantity of suggested types and modifications of bronchus stump sutures is evidence of this. The shortcoming of hand and mechanical sutures traditionally used at present is their effect on the bronchial lumen. The bronchial lumen condition ruins the protective barrier of the mucous membrane. In this connection the development of new methods of bronchus stump capsulation without the above mentioned shortcoming is supposed to be the most effective development to improve lung surgery.",
author = "Filippov, {C. G.} and Sokolovich, {E. G.} and Topolnitskii, {E. B.}",
year = "2000",
month = jan,
day = "1",
doi = "10.1109/SPCMTT.2000.896122",
language = "English",
series = "Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "209--211",
editor = "Sinebryukhov, {Andrei A.}",
booktitle = "Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists",
address = "United States",
note = "6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000 ; Conference date: 28-02-2000 Through 03-03-2000",

}

RIS

TY - GEN

T1 - Titanium nickel construction with shape memory effect for bronchus stump capsulation with lung resection

AU - Filippov, C. G.

AU - Sokolovich, E. G.

AU - Topolnitskii, E. B.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - In spite of significant successes in the field of lung surgery such complications of the post-operative period as failure of the bronchus stump and bronchial fistulas are still serious problems. According to the information of foreign and native authors the frequency of complications amounts to from 2 up to 30%. Resulting from this mortality amounts to 70%. In terms of treatment success the recovery of such patients' health therefore accounts for no more than 30%. This makes the life quality and social adaptation of patients worse. In the opinion of most authors the main cause of the presented complications is the character and quality of the bronchial suture. A large quantity of suggested types and modifications of bronchus stump sutures is evidence of this. The shortcoming of hand and mechanical sutures traditionally used at present is their effect on the bronchial lumen. The bronchial lumen condition ruins the protective barrier of the mucous membrane. In this connection the development of new methods of bronchus stump capsulation without the above mentioned shortcoming is supposed to be the most effective development to improve lung surgery.

AB - In spite of significant successes in the field of lung surgery such complications of the post-operative period as failure of the bronchus stump and bronchial fistulas are still serious problems. According to the information of foreign and native authors the frequency of complications amounts to from 2 up to 30%. Resulting from this mortality amounts to 70%. In terms of treatment success the recovery of such patients' health therefore accounts for no more than 30%. This makes the life quality and social adaptation of patients worse. In the opinion of most authors the main cause of the presented complications is the character and quality of the bronchial suture. A large quantity of suggested types and modifications of bronchus stump sutures is evidence of this. The shortcoming of hand and mechanical sutures traditionally used at present is their effect on the bronchial lumen. The bronchial lumen condition ruins the protective barrier of the mucous membrane. In this connection the development of new methods of bronchus stump capsulation without the above mentioned shortcoming is supposed to be the most effective development to improve lung surgery.

UR - http://www.scopus.com/inward/record.url?scp=84952878852&partnerID=8YFLogxK

U2 - 10.1109/SPCMTT.2000.896122

DO - 10.1109/SPCMTT.2000.896122

M3 - Conference contribution

AN - SCOPUS:84952878852

T3 - Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000

SP - 209

EP - 211

BT - Proceedings of the 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists

A2 - Sinebryukhov, Andrei A.

PB - Institute of Electrical and Electronics Engineers Inc.

T2 - 6th International Scientific and Practical Conference of Students, Post-Graduates and Young Scientists: Modern Techniques and Technology, MTT 2000

Y2 - 28 February 2000 through 3 March 2000

ER -

ID: 45773005