Standard

Test of adiabatic spin flippers for application at pulsed neutron sources. / Kraan, W. H.; Grigoriev, S. V.; Rekveldt, M. Th; Fredrikze, H.; De Vroege, C. F.; Plomp, J.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 510, No. 3, 11.09.2003, p. 334-345.

Research output: Contribution to journalArticlepeer-review

Harvard

Kraan, WH, Grigoriev, SV, Rekveldt, MT, Fredrikze, H, De Vroege, CF & Plomp, J 2003, 'Test of adiabatic spin flippers for application at pulsed neutron sources', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 510, no. 3, pp. 334-345. https://doi.org/10.1016/S0168-9002(03)01812-6

APA

Kraan, W. H., Grigoriev, S. V., Rekveldt, M. T., Fredrikze, H., De Vroege, C. F., & Plomp, J. (2003). Test of adiabatic spin flippers for application at pulsed neutron sources. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 510(3), 334-345. https://doi.org/10.1016/S0168-9002(03)01812-6

Vancouver

Kraan WH, Grigoriev SV, Rekveldt MT, Fredrikze H, De Vroege CF, Plomp J. Test of adiabatic spin flippers for application at pulsed neutron sources. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2003 Sep 11;510(3):334-345. https://doi.org/10.1016/S0168-9002(03)01812-6

Author

Kraan, W. H. ; Grigoriev, S. V. ; Rekveldt, M. Th ; Fredrikze, H. ; De Vroege, C. F. ; Plomp, J. / Test of adiabatic spin flippers for application at pulsed neutron sources. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2003 ; Vol. 510, No. 3. pp. 334-345.

BibTeX

@article{3fe93101e58a4d86a560538eba6aa3db,
title = "Test of adiabatic spin flippers for application at pulsed neutron sources",
abstract = "Experimental results on the flipping efficiency are shown for a set of 2 V-coils as spin flipper and for a high-frequency flipper with adiabatic transition. The influence of the adiabaticity parameter is discussed. The merits of these adiabatic flippers are compared with the use of {"}monochromatic{"} flippers, when operated in a beam from a pulsed neutron source. It is concluded that for {"}long pulse{"} sources adiabatic flippers will be superior.",
keywords = "Adiabaticity parameter, Polarised neutrons, Pulsed source, Spin flipper",
author = "Kraan, {W. H.} and Grigoriev, {S. V.} and Rekveldt, {M. Th} and H. Fredrikze and {De Vroege}, {C. F.} and J. Plomp",
year = "2003",
month = sep,
day = "11",
doi = "10.1016/S0168-9002(03)01812-6",
language = "English",
volume = "510",
pages = "334--345",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "3",

}

RIS

TY - JOUR

T1 - Test of adiabatic spin flippers for application at pulsed neutron sources

AU - Kraan, W. H.

AU - Grigoriev, S. V.

AU - Rekveldt, M. Th

AU - Fredrikze, H.

AU - De Vroege, C. F.

AU - Plomp, J.

PY - 2003/9/11

Y1 - 2003/9/11

N2 - Experimental results on the flipping efficiency are shown for a set of 2 V-coils as spin flipper and for a high-frequency flipper with adiabatic transition. The influence of the adiabaticity parameter is discussed. The merits of these adiabatic flippers are compared with the use of "monochromatic" flippers, when operated in a beam from a pulsed neutron source. It is concluded that for "long pulse" sources adiabatic flippers will be superior.

AB - Experimental results on the flipping efficiency are shown for a set of 2 V-coils as spin flipper and for a high-frequency flipper with adiabatic transition. The influence of the adiabaticity parameter is discussed. The merits of these adiabatic flippers are compared with the use of "monochromatic" flippers, when operated in a beam from a pulsed neutron source. It is concluded that for "long pulse" sources adiabatic flippers will be superior.

KW - Adiabaticity parameter

KW - Polarised neutrons

KW - Pulsed source

KW - Spin flipper

UR - http://www.scopus.com/inward/record.url?scp=0041508701&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(03)01812-6

DO - 10.1016/S0168-9002(03)01812-6

M3 - Article

AN - SCOPUS:0041508701

VL - 510

SP - 334

EP - 345

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 3

ER -