New linac-injector for Nuclotron-NICA is planned to consist of quarter-wave coaxial cavities (QWR) having velocities of ~0.07c and ~0.12c (beam energy from 5 to 17 MeV). These cavities are to be superconducting and operating at 162 MHz. Current results of the QWR cavities electrodynamics simulations and geometry optimizations are presented.

Original languageEnglish
Title of host publication25th Russian Particle Accelerator Conference, RuPAC 2016
PublisherJACoW
Pages273-275
Number of pages3
ISBN (Electronic)9783954501816
StatePublished - 1 Jan 2016
Event25th Russian Particle Accelerator Conference, RuPAC 2016 - СПбГУ, St. Petersburg, Russian Federation
Duration: 21 Nov 201625 Nov 2016
Conference number: XXV

Publication series

Name25th Russian Particle Accelerator Conference, RuPAC 2016

Conference

Conference25th Russian Particle Accelerator Conference, RuPAC 2016
Abbreviated titleRuPAC 2016
Country/TerritoryRussian Federation
CitySt. Petersburg
Period21/11/1625/11/16

    Scopus subject areas

  • Nuclear and High Energy Physics

ID: 43736813