title = "On-site sample preparation for benzo[a]pyrene in soils via pipette-tip based extraction with hydrophobic deep eutectic solvents and direct HPLC-FLD analysis",
abstract = "A novel field-deployable sample-preparation strategy for the determination of benzo[a]pyrene in soils was developed based on pipette-tip assisted extraction using a hydrophobic deep eutectic solvent (DES) followed by dispersive liquid-liquid microextraction (DLLME) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD). This approach represents a field-assisted extraction method, combining on-site sampling with lab-based detection. In the proposed approach, 1000 mg of soil is placed into a disposable pipette tip equipped with a porous frit and sealed with a PTFE membrane, after which 6.0 mL of a methanol-diluted thymol:hexanol DES (1000 mg, 1:1, mol/mol) is aspirated and dispensed through the sample seven times, enabling rapid and efficient on-site extraction of benzo[ a ]pyrene directly at the sampling site. The obtained extract is transported to the laboratory, where the addition of water induces phase separation and concentrates the analyte into a small hydrophobic DES phase suitable for direct HPLC-FLD injection without evaporation or clean-up. The extraction process requires less than 10 min and does not involve heating, sonication, or mechanical agitation. The method provides a linear response in the range of 5 to 100 μg kg−1 with a coefficient of determination R2 = 0.999, a limit of detection of 2 μg kg−1 and a limit of quantification of 5 μg kg−1. Intra- and inter-day precision did not exceed 7 %, while recoveries from spiked and certified reference soils ranged from 88 % to 113 %. The results were statistically indistinguishable from those obtained by a GC–MS reference procedure at the 95 % confidence level. The proposed methodology represents the first implementation of hydrophobic deep eutectic solvents for on-site soil extraction of polycyclic aromatic hydrocarbons using a pipette-tip format. By decoupling sampling from laboratory analysis and enabling transport of extracts instead of bulk soil, the approach significantly reduces logistical constraints, contamination risks and solvent consumption, offering a powerful new platform for rapid environmental monitoring of carcinogenic PAHs.",
keywords = "Benzo[a]pyrene, Deep eutectic solvents, HPLC-FLD, On-site sample preparation, Polycyclic aromatic hydrocarbons, Soil analysis",
author = "Крехова, {Фируза Миратовна} and Мещева, {Дарья Александровна} and Петрова, {Полина Павловна} and Низов, {Егор Рэмович} and Шишов, {Андрей Юрьевич} and Булатов, {Андрей Васильевич}",
year = "2026",
month = sep,
day = "1",
doi = "10.1016/j.talanta.2026.129913",
language = "English",
volume = "307",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - On-site sample preparation for benzo[a]pyrene in soils via pipette-tip based extraction with hydrophobic deep eutectic solvents and direct HPLC-FLD analysis

AU - Крехова, Фируза Миратовна

AU - Мещева, Дарья Александровна

AU - Петрова, Полина Павловна

AU - Низов, Егор Рэмович

AU - Шишов, Андрей Юрьевич

AU - Булатов, Андрей Васильевич

PY - 2026/9/1

Y1 - 2026/9/1

N2 - A novel field-deployable sample-preparation strategy for the determination of benzo[a]pyrene in soils was developed based on pipette-tip assisted extraction using a hydrophobic deep eutectic solvent (DES) followed by dispersive liquid-liquid microextraction (DLLME) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD). This approach represents a field-assisted extraction method, combining on-site sampling with lab-based detection. In the proposed approach, 1000 mg of soil is placed into a disposable pipette tip equipped with a porous frit and sealed with a PTFE membrane, after which 6.0 mL of a methanol-diluted thymol:hexanol DES (1000 mg, 1:1, mol/mol) is aspirated and dispensed through the sample seven times, enabling rapid and efficient on-site extraction of benzo[ a ]pyrene directly at the sampling site. The obtained extract is transported to the laboratory, where the addition of water induces phase separation and concentrates the analyte into a small hydrophobic DES phase suitable for direct HPLC-FLD injection without evaporation or clean-up. The extraction process requires less than 10 min and does not involve heating, sonication, or mechanical agitation. The method provides a linear response in the range of 5 to 100 μg kg−1 with a coefficient of determination R2 = 0.999, a limit of detection of 2 μg kg−1 and a limit of quantification of 5 μg kg−1. Intra- and inter-day precision did not exceed 7 %, while recoveries from spiked and certified reference soils ranged from 88 % to 113 %. The results were statistically indistinguishable from those obtained by a GC–MS reference procedure at the 95 % confidence level. The proposed methodology represents the first implementation of hydrophobic deep eutectic solvents for on-site soil extraction of polycyclic aromatic hydrocarbons using a pipette-tip format. By decoupling sampling from laboratory analysis and enabling transport of extracts instead of bulk soil, the approach significantly reduces logistical constraints, contamination risks and solvent consumption, offering a powerful new platform for rapid environmental monitoring of carcinogenic PAHs.

AB - A novel field-deployable sample-preparation strategy for the determination of benzo[a]pyrene in soils was developed based on pipette-tip assisted extraction using a hydrophobic deep eutectic solvent (DES) followed by dispersive liquid-liquid microextraction (DLLME) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD). This approach represents a field-assisted extraction method, combining on-site sampling with lab-based detection. In the proposed approach, 1000 mg of soil is placed into a disposable pipette tip equipped with a porous frit and sealed with a PTFE membrane, after which 6.0 mL of a methanol-diluted thymol:hexanol DES (1000 mg, 1:1, mol/mol) is aspirated and dispensed through the sample seven times, enabling rapid and efficient on-site extraction of benzo[ a ]pyrene directly at the sampling site. The obtained extract is transported to the laboratory, where the addition of water induces phase separation and concentrates the analyte into a small hydrophobic DES phase suitable for direct HPLC-FLD injection without evaporation or clean-up. The extraction process requires less than 10 min and does not involve heating, sonication, or mechanical agitation. The method provides a linear response in the range of 5 to 100 μg kg−1 with a coefficient of determination R2 = 0.999, a limit of detection of 2 μg kg−1 and a limit of quantification of 5 μg kg−1. Intra- and inter-day precision did not exceed 7 %, while recoveries from spiked and certified reference soils ranged from 88 % to 113 %. The results were statistically indistinguishable from those obtained by a GC–MS reference procedure at the 95 % confidence level. The proposed methodology represents the first implementation of hydrophobic deep eutectic solvents for on-site soil extraction of polycyclic aromatic hydrocarbons using a pipette-tip format. By decoupling sampling from laboratory analysis and enabling transport of extracts instead of bulk soil, the approach significantly reduces logistical constraints, contamination risks and solvent consumption, offering a powerful new platform for rapid environmental monitoring of carcinogenic PAHs.

KW - Benzo[a]pyrene

KW - Deep eutectic solvents

KW - HPLC-FLD

KW - On-site sample preparation

KW - Polycyclic aromatic hydrocarbons

KW - Soil analysis

UR - https://www.mendeley.com/catalogue/c7b78629-7aee-3f87-8846-6ed34c078f12/

U2 - 10.1016/j.talanta.2026.129913

DO - 10.1016/j.talanta.2026.129913

M3 - Article

VL - 307

JO - Talanta

JF - Talanta

SN - 0039-9140

M1 - 129913

ER -

ID: 154982727