Standard

Method for the definition of “reference positions” for the insertion of transosseous elements. / Solomin, Leonid Nikolaevich; Andrianov, Maxim Vasil’Evich; Inyushin, Roman Nikolaevich; Mykalo, Dmitry Alexandrovich; Kulesh, Pavel Nikolaevich.

The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, 2012. p. 1519-1530.

Research output: Chapter in Book/Report/Conference proceeding › Chapter › Research › peer-review

Harvard

Solomin, LN, Andrianov, MVE, Inyushin, RN, Mykalo, DA & Kulesh, PN 2012, Method for the definition of “reference positions” for the insertion of transosseous elements. in The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, pp. 1519-1530. https://doi.org/10.1007/978-88-470-2619-3_35

APA

Solomin, L. N., Andrianov, M. VE., Inyushin, R. N., Mykalo, D. A., & Kulesh, P. N. (2012). Method for the definition of “reference positions” for the insertion of transosseous elements. In The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices (pp. 1519-1530). Springer Nature. https://doi.org/10.1007/978-88-470-2619-3_35

Vancouver

Solomin LN, Andrianov MVE, Inyushin RN, Mykalo DA, Kulesh PN. Method for the definition of “reference positions” for the insertion of transosseous elements. In The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature. 2012. p. 1519-1530 https://doi.org/10.1007/978-88-470-2619-3_35

Author

Solomin, Leonid Nikolaevich ; Andrianov, Maxim Vasil’Evich ; Inyushin, Roman Nikolaevich ; Mykalo, Dmitry Alexandrovich ; Kulesh, Pavel Nikolaevich. / Method for the definition of “reference positions” for the insertion of transosseous elements. The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, 2012. pp. 1519-1530

BibTeX

@inbook{25fd95752faf41448f22a15a06e7be2f,
title = "Method for the definition of “reference positions” for the insertion of transosseous elements",
abstract = "“Reference positions” for the insertion of transosseous elements must comply with two very important requirements: minimum soft-tissue displacement during movements in the joints adjacent to the segment, and no risk of damage to the great vessels and nerves. The use of positions with minimum soft-tissue displacement decreases the risk not only of pin-induced joint stiffness, but also of pin-tract infection because chronic traumatic soft-tissue injury by the transosseous elements is reduced. If soft-tissue displacement is not considered, the term “safe positions” is used. ",
author = "Solomin, {Leonid Nikolaevich} and Andrianov, {Maxim Vasil{\textquoteright}Evich} and Inyushin, {Roman Nikolaevich} and Mykalo, {Dmitry Alexandrovich} and Kulesh, {Pavel Nikolaevich}",
year = "2012",
month = jan,
day = "1",
doi = "10.1007/978-88-470-2619-3_35",
language = "English",
isbn = "9788847026186",
pages = "1519--1530",
booktitle = "The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices",
publisher = "Springer Nature",
address = "Germany",

}

RIS

TY - CHAP

T1 - Method for the definition of “reference positions” for the insertion of transosseous elements

AU - Solomin, Leonid Nikolaevich

AU - Andrianov, Maxim Vasil’Evich

AU - Inyushin, Roman Nikolaevich

AU - Mykalo, Dmitry Alexandrovich

AU - Kulesh, Pavel Nikolaevich

PY - 2012/1/1

Y1 - 2012/1/1

N2 - “Reference positions” for the insertion of transosseous elements must comply with two very important requirements: minimum soft-tissue displacement during movements in the joints adjacent to the segment, and no risk of damage to the great vessels and nerves. The use of positions with minimum soft-tissue displacement decreases the risk not only of pin-induced joint stiffness, but also of pin-tract infection because chronic traumatic soft-tissue injury by the transosseous elements is reduced. If soft-tissue displacement is not considered, the term “safe positions” is used.

AB - “Reference positions” for the insertion of transosseous elements must comply with two very important requirements: minimum soft-tissue displacement during movements in the joints adjacent to the segment, and no risk of damage to the great vessels and nerves. The use of positions with minimum soft-tissue displacement decreases the risk not only of pin-induced joint stiffness, but also of pin-tract infection because chronic traumatic soft-tissue injury by the transosseous elements is reduced. If soft-tissue displacement is not considered, the term “safe positions” is used.

UR - http://www.scopus.com/inward/record.url?scp=84957007884&partnerID=8YFLogxK

U2 - 10.1007/978-88-470-2619-3_35

DO - 10.1007/978-88-470-2619-3_35

M3 - Chapter

AN - SCOPUS:84957007884

SN - 9788847026186

SP - 1519

EP - 1530

BT - The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices

PB - Springer Nature

ER -

ID: 49736371