Standard

Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer. / Chernaya, A. V.; Kanaev, S. V.; Krzhivitsky, P. L.; Krivorotko, P. V.; Artemieva, A. S.; Busko, E. A.; Shumakova, T. A.; Bashlyk, V. O.

In: Voprosy Onkologii, Vol. 63, No. 6, 01.01.2017, p. 876-881.

Research output: Contribution to journalArticlepeer-review

Harvard

Chernaya, AV, Kanaev, SV, Krzhivitsky, PL, Krivorotko, PV, Artemieva, AS, Busko, EA, Shumakova, TA & Bashlyk, VO 2017, 'Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer', Voprosy Onkologii, vol. 63, no. 6, pp. 876-881.

APA

Chernaya, A. V., Kanaev, S. V., Krzhivitsky, P. L., Krivorotko, P. V., Artemieva, A. S., Busko, E. A., Shumakova, T. A., & Bashlyk, V. O. (2017). Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer. Voprosy Onkologii, 63(6), 876-881.

Vancouver

Chernaya AV, Kanaev SV, Krzhivitsky PL, Krivorotko PV, Artemieva AS, Busko EA et al. Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer. Voprosy Onkologii. 2017 Jan 1;63(6):876-881.

Author

Chernaya, A. V. ; Kanaev, S. V. ; Krzhivitsky, P. L. ; Krivorotko, P. V. ; Artemieva, A. S. ; Busko, E. A. ; Shumakova, T. A. ; Bashlyk, V. O. / Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer. In: Voprosy Onkologii. 2017 ; Vol. 63, No. 6. pp. 876-881.

BibTeX

@article{d6329f16fe984887accba2c6ebee0e4d,
title = "Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer",
abstract = "Objective: To compare diagnostic capability of mammography and mammoscintigraphy with Tc-methoxyisobutylisoni-trile (MIBI) in diagnostic of multicentric breast cancer. Material and Methods: We respectively analyzed 437 consecutive women with suspected breast cancer between 2014 to 2016. All of them underwent mammography and mammoscintigraphy. Craniocaudal and mediolateral oblique images were obtained. Mammoscintigraphy was performed 15-20 min. after intravenous injection 740 MBq of Tc-methoxyisobutylisoni-trile (MIBI). Final interpretation of the data was done according to histological examination. Results: Breast cancer was detect in 367(84%) of patients. Most of them 320(87%) had single node breast cancer and 47(13%) - multicentric breast cancer. Sensitivity, specificity and accuracy in diagnostic of multicentric breast cancer were 40,4%, 95,3%, 88% for mammography and 83%, 98%, 96% for mammoscintigraphy respectively. The combination of these methods allowed significantly increase sensitivity of breast cancer detection up to 93,6%. Specificity was 93,4%.",
keywords = "Breast cancer, Mammography, Mammoscintigraphy, Multicentric breast cancer",
author = "Chernaya, {A. V.} and Kanaev, {S. V.} and Krzhivitsky, {P. L.} and Krivorotko, {P. V.} and Artemieva, {A. S.} and Busko, {E. A.} and Shumakova, {T. A.} and Bashlyk, {V. O.}",
year = "2017",
month = jan,
day = "1",
language = "English",
volume = "63",
pages = "876--881",
journal = "Вопросы онкологии",
issn = "0507-3758",
publisher = "Медицина",
number = "6",

}

RIS

TY - JOUR

T1 - Mammography and mammoscintigraphy with 99m Tc-MIBI in the diagnosis of multicentric breast cancer

AU - Chernaya, A. V.

AU - Kanaev, S. V.

AU - Krzhivitsky, P. L.

AU - Krivorotko, P. V.

AU - Artemieva, A. S.

AU - Busko, E. A.

AU - Shumakova, T. A.

AU - Bashlyk, V. O.

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Objective: To compare diagnostic capability of mammography and mammoscintigraphy with Tc-methoxyisobutylisoni-trile (MIBI) in diagnostic of multicentric breast cancer. Material and Methods: We respectively analyzed 437 consecutive women with suspected breast cancer between 2014 to 2016. All of them underwent mammography and mammoscintigraphy. Craniocaudal and mediolateral oblique images were obtained. Mammoscintigraphy was performed 15-20 min. after intravenous injection 740 MBq of Tc-methoxyisobutylisoni-trile (MIBI). Final interpretation of the data was done according to histological examination. Results: Breast cancer was detect in 367(84%) of patients. Most of them 320(87%) had single node breast cancer and 47(13%) - multicentric breast cancer. Sensitivity, specificity and accuracy in diagnostic of multicentric breast cancer were 40,4%, 95,3%, 88% for mammography and 83%, 98%, 96% for mammoscintigraphy respectively. The combination of these methods allowed significantly increase sensitivity of breast cancer detection up to 93,6%. Specificity was 93,4%.

AB - Objective: To compare diagnostic capability of mammography and mammoscintigraphy with Tc-methoxyisobutylisoni-trile (MIBI) in diagnostic of multicentric breast cancer. Material and Methods: We respectively analyzed 437 consecutive women with suspected breast cancer between 2014 to 2016. All of them underwent mammography and mammoscintigraphy. Craniocaudal and mediolateral oblique images were obtained. Mammoscintigraphy was performed 15-20 min. after intravenous injection 740 MBq of Tc-methoxyisobutylisoni-trile (MIBI). Final interpretation of the data was done according to histological examination. Results: Breast cancer was detect in 367(84%) of patients. Most of them 320(87%) had single node breast cancer and 47(13%) - multicentric breast cancer. Sensitivity, specificity and accuracy in diagnostic of multicentric breast cancer were 40,4%, 95,3%, 88% for mammography and 83%, 98%, 96% for mammoscintigraphy respectively. The combination of these methods allowed significantly increase sensitivity of breast cancer detection up to 93,6%. Specificity was 93,4%.

KW - Breast cancer

KW - Mammography

KW - Mammoscintigraphy

KW - Multicentric breast cancer

UR - http://www.scopus.com/inward/record.url?scp=85044212558&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:85044212558

VL - 63

SP - 876

EP - 881

JO - Вопросы онкологии

JF - Вопросы онкологии

SN - 0507-3758

IS - 6

ER -

ID: 38684322