Research output: Contribution to journal › Article › peer-review
L-tyrosine-stabilized silver nanoparticles for colorimetric detection of hydrogen peroxide. / Сыч, Томаш Сергеевич; Шеховцов, Николай Викторович; Буглак, Андрей Андреевич; Кононов, Алексей Игоревич.
In: SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, Vol. 354, 127631, 05.06.2026.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - L-tyrosine-stabilized silver nanoparticles for colorimetric detection of hydrogen peroxide
AU - Сыч, Томаш Сергеевич
AU - Шеховцов, Николай Викторович
AU - Буглак, Андрей Андреевич
AU - Кононов, Алексей Игоревич
PY - 2026/6/5
Y1 - 2026/6/5
N2 - Hydrogen peroxide (H2O2) is a type of reactive oxygen species widespread in biological tissues. It is an important biomarker of oxidative stress, cancers, asthma, etc. In this regard, development of precise and cost-effective sensors for detection of H2O2 in vitro and in vivo is of great significance for biomedicine. In this paper, a colorimetric method is introduced for sensing hydrogen peroxide using tyrosine-stabilized silver nanoparticles. In aqueous solutions, the colorimetric method demonstrated a linear range of 0.4–5 μM with a detection limit (LOD) of 150 nM, whereas in human blood serum the linear range was within 0.7–20 μM characterized by a LOD of 250 nM. Recovery tests in blood serum yielded results within the acceptable range 96–101%, confirming the method's accuracy and reliability. Possible mechanisms of silver nanoparticles/nanoclusters interaction with H2O2 during its detection were examined using fluorescence spectroscopy and dynamic light scattering methods.
AB - Hydrogen peroxide (H2O2) is a type of reactive oxygen species widespread in biological tissues. It is an important biomarker of oxidative stress, cancers, asthma, etc. In this regard, development of precise and cost-effective sensors for detection of H2O2 in vitro and in vivo is of great significance for biomedicine. In this paper, a colorimetric method is introduced for sensing hydrogen peroxide using tyrosine-stabilized silver nanoparticles. In aqueous solutions, the colorimetric method demonstrated a linear range of 0.4–5 μM with a detection limit (LOD) of 150 nM, whereas in human blood serum the linear range was within 0.7–20 μM characterized by a LOD of 250 nM. Recovery tests in blood serum yielded results within the acceptable range 96–101%, confirming the method's accuracy and reliability. Possible mechanisms of silver nanoparticles/nanoclusters interaction with H2O2 during its detection were examined using fluorescence spectroscopy and dynamic light scattering methods.
KW - Blood serum
KW - Colorimetric detection
KW - Dynamic light scattering
KW - Hydrogen peroxide
KW - Silver nanoparticles
UR - https://www.mendeley.com/catalogue/ea23be5d-7659-3c87-9471-0bd03d217a15/
U2 - 10.1016/j.saa.2026.127631
DO - 10.1016/j.saa.2026.127631
M3 - Article
VL - 354
JO - SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
JF - SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
SN - 1386-1425
M1 - 127631
ER -
ID: 149593627