@article{65c936e156d5483e97f6a0f294019817,
title = "Effect of the Addition of Polyacrylic Acid of Different Molecular Weights to Coagulation Bath on the Structure and Performance of Polysulfone Ultrafiltration Membranes",
abstract = "Membrane fouling is a serious issue in membrane technology which cannot be completely avoided but can be diminished. The perspective technique of membrane modification is the introduction of hydrophilic polymers or polyelectrolytes into the coagulation bath during membrane preparation via non-solvent-induced phase separation. The influence of polyacrylic acid (PAA) molecular weight (100,000, 250,000 and 450,000 g·mol -1) added to the aqueous coagulation bath (0.4-2.0 wt.%) on the polysulfone membrane structure, surface roughness, water contact angle and zeta potential of the selective layer, as well as the separation and antifouling performance, was systematically studied. It was found that membranes obtained via the addition of PAA with higher molecular weight feature smaller pore size and porosity, extremely high hydrophilicity and higher values of negative charge of membrane surface. It was shown that the increase in PAA concentration from 0.4 wt.% to 2.0 wt.% for all studied PAA molecular weights yielded a substantial decrease in water contact angle compared with the reference membrane (65 ± 2°) (from 27 ± 2° to 17 ± 2° for PAA with M n = 100,000 g·mol -1; from 25 ± 2° to 16 ± 2° for PAA with M n = 250,000 g·mol -1; and from 19 ± 2° to 10 ± 2° for PAA with M n = 450,000 g·mol -1). An increase in PAA molecular weight from 100,000 to 450,000 g·mol -1 led to a decrease in membrane permeability, an increase in rejection and tailoring excellent antifouling performance in the ultrafiltration of humic acid solutions. The fouling recovery ratio increased from 73% for the reference membrane up to 91%, 100% and 136% for membranes modified with the addition to the coagulation bath of 1.5 wt.% of PAA with molecular weights of 100,000 g·mol -1, 250,000 g·mol -1 and 450,000 g·mol -1, respectively. Overall, the addition of PAA of different molecular weights to the coagulation bath is an efficient tool to adjust membrane separation and antifouling properties for different separation tasks. ",
keywords = "fouling, hydrophilization, membrane modification, molecular weight, polyacrylic acid, polysulfone, ultrafiltration",
author = "Плиско, {Татьяна Викторовна} and Бурть, {Екатерина Сергеевна} and Пенькова, {Анастасия Владимировна} and Дмитренко, {Мария Евгеньевна} and Кузьминова, {Анна Игоревна} and Ермаков, {Сергей Сергеевич} and Александр Бильдюкевич",
year = "2023",
month = mar,
day = "27",
doi = "10.3390/polym15071664",
language = "English",
volume = "15",
journal = "Polymers",
issn = "2073-4360",
publisher = "MDPI AG",
number = "7",

}

RIS

TY - JOUR

T1 - Effect of the Addition of Polyacrylic Acid of Different Molecular Weights to Coagulation Bath on the Structure and Performance of Polysulfone Ultrafiltration Membranes

AU - Плиско, Татьяна Викторовна

AU - Бурть, Екатерина Сергеевна

AU - Пенькова, Анастасия Владимировна

AU - Дмитренко, Мария Евгеньевна

AU - Кузьминова, Анна Игоревна

AU - Ермаков, Сергей Сергеевич

AU - Бильдюкевич, Александр

PY - 2023/3/27

Y1 - 2023/3/27

N2 - Membrane fouling is a serious issue in membrane technology which cannot be completely avoided but can be diminished. The perspective technique of membrane modification is the introduction of hydrophilic polymers or polyelectrolytes into the coagulation bath during membrane preparation via non-solvent-induced phase separation. The influence of polyacrylic acid (PAA) molecular weight (100,000, 250,000 and 450,000 g·mol -1) added to the aqueous coagulation bath (0.4-2.0 wt.%) on the polysulfone membrane structure, surface roughness, water contact angle and zeta potential of the selective layer, as well as the separation and antifouling performance, was systematically studied. It was found that membranes obtained via the addition of PAA with higher molecular weight feature smaller pore size and porosity, extremely high hydrophilicity and higher values of negative charge of membrane surface. It was shown that the increase in PAA concentration from 0.4 wt.% to 2.0 wt.% for all studied PAA molecular weights yielded a substantial decrease in water contact angle compared with the reference membrane (65 ± 2°) (from 27 ± 2° to 17 ± 2° for PAA with M n = 100,000 g·mol -1; from 25 ± 2° to 16 ± 2° for PAA with M n = 250,000 g·mol -1; and from 19 ± 2° to 10 ± 2° for PAA with M n = 450,000 g·mol -1). An increase in PAA molecular weight from 100,000 to 450,000 g·mol -1 led to a decrease in membrane permeability, an increase in rejection and tailoring excellent antifouling performance in the ultrafiltration of humic acid solutions. The fouling recovery ratio increased from 73% for the reference membrane up to 91%, 100% and 136% for membranes modified with the addition to the coagulation bath of 1.5 wt.% of PAA with molecular weights of 100,000 g·mol -1, 250,000 g·mol -1 and 450,000 g·mol -1, respectively. Overall, the addition of PAA of different molecular weights to the coagulation bath is an efficient tool to adjust membrane separation and antifouling properties for different separation tasks.

AB - Membrane fouling is a serious issue in membrane technology which cannot be completely avoided but can be diminished. The perspective technique of membrane modification is the introduction of hydrophilic polymers or polyelectrolytes into the coagulation bath during membrane preparation via non-solvent-induced phase separation. The influence of polyacrylic acid (PAA) molecular weight (100,000, 250,000 and 450,000 g·mol -1) added to the aqueous coagulation bath (0.4-2.0 wt.%) on the polysulfone membrane structure, surface roughness, water contact angle and zeta potential of the selective layer, as well as the separation and antifouling performance, was systematically studied. It was found that membranes obtained via the addition of PAA with higher molecular weight feature smaller pore size and porosity, extremely high hydrophilicity and higher values of negative charge of membrane surface. It was shown that the increase in PAA concentration from 0.4 wt.% to 2.0 wt.% for all studied PAA molecular weights yielded a substantial decrease in water contact angle compared with the reference membrane (65 ± 2°) (from 27 ± 2° to 17 ± 2° for PAA with M n = 100,000 g·mol -1; from 25 ± 2° to 16 ± 2° for PAA with M n = 250,000 g·mol -1; and from 19 ± 2° to 10 ± 2° for PAA with M n = 450,000 g·mol -1). An increase in PAA molecular weight from 100,000 to 450,000 g·mol -1 led to a decrease in membrane permeability, an increase in rejection and tailoring excellent antifouling performance in the ultrafiltration of humic acid solutions. The fouling recovery ratio increased from 73% for the reference membrane up to 91%, 100% and 136% for membranes modified with the addition to the coagulation bath of 1.5 wt.% of PAA with molecular weights of 100,000 g·mol -1, 250,000 g·mol -1 and 450,000 g·mol -1, respectively. Overall, the addition of PAA of different molecular weights to the coagulation bath is an efficient tool to adjust membrane separation and antifouling properties for different separation tasks.

KW - fouling

KW - hydrophilization

KW - membrane modification

KW - molecular weight

KW - polyacrylic acid

KW - polysulfone

KW - ultrafiltration

UR - https://www.mendeley.com/catalogue/6e18aeb4-28b6-3862-879a-633e5b06aaf3/

U2 - 10.3390/polym15071664

DO - 10.3390/polym15071664

M3 - Article

C2 - 37050278

VL - 15

JO - Polymers

JF - Polymers

SN - 2073-4360

IS - 7

M1 - 1664

ER -