N2 - A sector field inductively coupled mass spectrometry method for the determination of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cs, Cu, Fe, Mn, Ni, Pb, Se, Sr, Tl, U, V and Zn in whole blood and urine was designed. Microwave-assisted digestion with concentrated nitric acid was used for blood samples. Urine samples were analyzed after 1/50 (v/v) dilution with 5% (v/v) nitric acid. For beryllium the necessity of medium resolution mode (R=4000) was shown. Method validation was performed using blood and urine reference materials and by analyzing of spiked samples. For the designed method relative standard deviation (RSD) for the concentration range 0.01 – 1.0 μg/L was 5 – 10%. RSD did not exceed 3% when trace elements concentrations were above 1.0 μg/L. Method detection limits (3σ): Ag 0.7 ng/L, Al 16 ng/L, As 3.4 ng/L, Ba 0.02 ng/L, Be 1.5 ng/L, Cd 7.7 ng/L, Co 1.0 ng/L, Cr 2.8 ng/L, Cs 9.8 ng/L, Cu 27 ng/L, Fe 1.1 ng/L, Mn 1.8 ng/L, Ni 17 ng/L, Pb 13 ng/L, Se 0.07 ng/L, Sr 5.7 ng/L, Tl 0.2 ng/L, U 0.1 ng/L, V 0.7 ng/L an
AB - A sector field inductively coupled mass spectrometry method for the determination of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cs, Cu, Fe, Mn, Ni, Pb, Se, Sr, Tl, U, V and Zn in whole blood and urine was designed. Microwave-assisted digestion with concentrated nitric acid was used for blood samples. Urine samples were analyzed after 1/50 (v/v) dilution with 5% (v/v) nitric acid. For beryllium the necessity of medium resolution mode (R=4000) was shown. Method validation was performed using blood and urine reference materials and by analyzing of spiked samples. For the designed method relative standard deviation (RSD) for the concentration range 0.01 – 1.0 μg/L was 5 – 10%. RSD did not exceed 3% when trace elements concentrations were above 1.0 μg/L. Method detection limits (3σ): Ag 0.7 ng/L, Al 16 ng/L, As 3.4 ng/L, Ba 0.02 ng/L, Be 1.5 ng/L, Cd 7.7 ng/L, Co 1.0 ng/L, Cr 2.8 ng/L, Cs 9.8 ng/L, Cu 27 ng/L, Fe 1.1 ng/L, Mn 1.8 ng/L, Ni 17 ng/L, Pb 13 ng/L, Se 0.07 ng/L, Sr 5.7 ng/L, Tl 0.2 ng/L, U 0.1 ng/L, V 0.7 ng/L an
KW - Biomonitoring
KW - Blood
KW - Urine
KW - Beryllium
KW - Trace elements
KW - Sector field inductively coupled mass spectrometry
KW - Inductively coupled plasma optical emission spectrometry