Standard

The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis. / Ermolenko, Yu; Yoshinobu, T.; Mourzina, Yu; Furuichi, K.; Levichev, S.; Schöning, M. J.; Vlasov, Yu; Iwasaki, H.

в: Talanta, Том 59, № 4, 10.03.2003, стр. 785-795.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Ermolenko, Y, Yoshinobu, T, Mourzina, Y, Furuichi, K, Levichev, S, Schöning, MJ, Vlasov, Y & Iwasaki, H 2003, 'The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis', Talanta, Том. 59, № 4, стр. 785-795. https://doi.org/10.1016/S0039-9140(02)00620-3

APA

Ermolenko, Y., Yoshinobu, T., Mourzina, Y., Furuichi, K., Levichev, S., Schöning, M. J., Vlasov, Y., & Iwasaki, H. (2003). The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis. Talanta, 59(4), 785-795. https://doi.org/10.1016/S0039-9140(02)00620-3

Vancouver

Ermolenko Y, Yoshinobu T, Mourzina Y, Furuichi K, Levichev S, Schöning MJ и пр. The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis. Talanta. 2003 Март 10;59(4):785-795. https://doi.org/10.1016/S0039-9140(02)00620-3

Author

Ermolenko, Yu ; Yoshinobu, T. ; Mourzina, Yu ; Furuichi, K. ; Levichev, S. ; Schöning, M. J. ; Vlasov, Yu ; Iwasaki, H. / The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis. в: Talanta. 2003 ; Том 59, № 4. стр. 785-795.

BibTeX

@article{6ea76ccd2dc146ec8bcec3a084f64910,
title = "The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis",
abstract = "In the present work a double ion sensor based on a laser scanned semiconductor transducer (LSST) for the simultaneous determination of K+- and Ca2+ -ions in solutions has been developed. Specially elaborated ion-sensitive membrane compositions based on valinomycin and calcium ionophore calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (t-HDOPP-Ca) were deposited as separate layers on a silanized surface of the Si/SiO2/Si3N4-transducer. The proposed multi-sensor exhibits theoretical sensitivities and the detection limits of the sensor were found to be 2 x 10-6 mol 1-1 for K+ and 5 x 10-6 mol 1-1 for Ca2+. The elaborated double sensor is proposed for the first time as a prototype of a new type of multi-sensor systems for chemical analysis.",
keywords = "Double sensor, Laser scanned semiconductor transducer (LSST), Potassium and calcium selectivity, Solvent-polymeric membrane",
author = "Yu Ermolenko and T. Yoshinobu and Yu Mourzina and K. Furuichi and S. Levichev and Sch{\"o}ning, {M. J.} and Yu Vlasov and H. Iwasaki",
year = "2003",
month = mar,
day = "10",
doi = "10.1016/S0039-9140(02)00620-3",
language = "English",
volume = "59",
pages = "785--795",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "4",

}

RIS

TY - JOUR

T1 - The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis

AU - Ermolenko, Yu

AU - Yoshinobu, T.

AU - Mourzina, Yu

AU - Furuichi, K.

AU - Levichev, S.

AU - Schöning, M. J.

AU - Vlasov, Yu

AU - Iwasaki, H.

PY - 2003/3/10

Y1 - 2003/3/10

N2 - In the present work a double ion sensor based on a laser scanned semiconductor transducer (LSST) for the simultaneous determination of K+- and Ca2+ -ions in solutions has been developed. Specially elaborated ion-sensitive membrane compositions based on valinomycin and calcium ionophore calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (t-HDOPP-Ca) were deposited as separate layers on a silanized surface of the Si/SiO2/Si3N4-transducer. The proposed multi-sensor exhibits theoretical sensitivities and the detection limits of the sensor were found to be 2 x 10-6 mol 1-1 for K+ and 5 x 10-6 mol 1-1 for Ca2+. The elaborated double sensor is proposed for the first time as a prototype of a new type of multi-sensor systems for chemical analysis.

AB - In the present work a double ion sensor based on a laser scanned semiconductor transducer (LSST) for the simultaneous determination of K+- and Ca2+ -ions in solutions has been developed. Specially elaborated ion-sensitive membrane compositions based on valinomycin and calcium ionophore calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (t-HDOPP-Ca) were deposited as separate layers on a silanized surface of the Si/SiO2/Si3N4-transducer. The proposed multi-sensor exhibits theoretical sensitivities and the detection limits of the sensor were found to be 2 x 10-6 mol 1-1 for K+ and 5 x 10-6 mol 1-1 for Ca2+. The elaborated double sensor is proposed for the first time as a prototype of a new type of multi-sensor systems for chemical analysis.

KW - Double sensor

KW - Laser scanned semiconductor transducer (LSST)

KW - Potassium and calcium selectivity

KW - Solvent-polymeric membrane

UR - http://www.scopus.com/inward/record.url?scp=0037429609&partnerID=8YFLogxK

U2 - 10.1016/S0039-9140(02)00620-3

DO - 10.1016/S0039-9140(02)00620-3

M3 - Article

AN - SCOPUS:0037429609

VL - 59

SP - 785

EP - 795

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 4

ER -

ID: 61610504