Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Silicone Rubber Treatment with a Sodium Chloride Solution in the Presence of an Electric Field. / Полуэктова, Карина Дмитриевна; Васильков, Сергей Андреевич; Слесаренко, Анастасия Витальевна.
в: Surface Engineering and Applied Electrochemistry, Том 60, № 2, 26.04.2024, стр. 260–267.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Silicone Rubber Treatment with a Sodium Chloride Solution in the Presence of an Electric Field
AU - Полуэктова, Карина Дмитриевна
AU - Васильков, Сергей Андреевич
AU - Слесаренко, Анастасия Витальевна
PY - 2024/4/26
Y1 - 2024/4/26
N2 - Abstract: High voltage silicone insulators that are placed close to coastal marine areas have the problem of salt fog depositing on their surfaces in the form of conductive droplets. Under the influence of an electric field, those droplets initiate partial discharges, which leads to the degradation of the hydrophobic properties of silicone rubber. This phenomenon, in which droplets serve as the cause of partial discharges, has been studied in considerable detail elsewhere. However, it remains unclear whether the droplets themselves, as moisture-laden areas, affect the properties of silicone rubber. The current work is focused on studying the combined effect of an AC electric field (E = 17 kV/cm) and a 4% solution of sodium chloride on the water-repellent properties of silicone rubber in the absence of electrical discharges. The results of the study show that the influence of moisture and an electric field leads to slowing down the droplet runoff from the inclined sample of Powersil 310 rubber. An AC electric field did not have a noticeable effect on the rate of water runoff; the slowdown was due to the pre-treatment of the sample with the solution.
AB - Abstract: High voltage silicone insulators that are placed close to coastal marine areas have the problem of salt fog depositing on their surfaces in the form of conductive droplets. Under the influence of an electric field, those droplets initiate partial discharges, which leads to the degradation of the hydrophobic properties of silicone rubber. This phenomenon, in which droplets serve as the cause of partial discharges, has been studied in considerable detail elsewhere. However, it remains unclear whether the droplets themselves, as moisture-laden areas, affect the properties of silicone rubber. The current work is focused on studying the combined effect of an AC electric field (E = 17 kV/cm) and a 4% solution of sodium chloride on the water-repellent properties of silicone rubber in the absence of electrical discharges. The results of the study show that the influence of moisture and an electric field leads to slowing down the droplet runoff from the inclined sample of Powersil 310 rubber. An AC electric field did not have a noticeable effect on the rate of water runoff; the slowdown was due to the pre-treatment of the sample with the solution.
KW - dynamic hydrophobicity
KW - high-voltage silicone insulation
KW - saline solution
KW - static contact angle
KW - water immersion
UR - https://www.mendeley.com/catalogue/dda41ab1-de77-3a81-88be-025258c921b3/
U2 - 10.3103/s1068375524020091
DO - 10.3103/s1068375524020091
M3 - Article
VL - 60
SP - 260
EP - 267
JO - Surface Engineering and Applied Electrochemistry
JF - Surface Engineering and Applied Electrochemistry
SN - 1068-3755
IS - 2
ER -
ID: 119393676