Standard

Sector multipad prototype of the FMD-MCP detector for ALICE. / Antropov, A. E.; Fedotov, A. V.; Feofilov, G. A.; Izrailov, E. K.; Kasatkin, V. A.; Klempt, W.; Kolojvari, A. A.; Larin, M. P.; Lazarev, V.; Novikov, I. A.; Stolyarov, O. I.; Tsimbal, F. A.; Tulina, T. A.; Valiev, F. F.; Vinogradov, L. I.

в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 419, № 2-3, 21.12.1998, стр. 654-659.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Antropov, AE, Fedotov, AV, Feofilov, GA, Izrailov, EK, Kasatkin, VA, Klempt, W, Kolojvari, AA, Larin, MP, Lazarev, V, Novikov, IA, Stolyarov, OI, Tsimbal, FA, Tulina, TA, Valiev, FF & Vinogradov, LI 1998, 'Sector multipad prototype of the FMD-MCP detector for ALICE', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 419, № 2-3, стр. 654-659. https://doi.org/10.1016/S0168-9002(98)00862-6

APA

Antropov, A. E., Fedotov, A. V., Feofilov, G. A., Izrailov, E. K., Kasatkin, V. A., Klempt, W., Kolojvari, A. A., Larin, M. P., Lazarev, V., Novikov, I. A., Stolyarov, O. I., Tsimbal, F. A., Tulina, T. A., Valiev, F. F., & Vinogradov, L. I. (1998). Sector multipad prototype of the FMD-MCP detector for ALICE. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 419(2-3), 654-659. https://doi.org/10.1016/S0168-9002(98)00862-6

Vancouver

Antropov AE, Fedotov AV, Feofilov GA, Izrailov EK, Kasatkin VA, Klempt W и пр. Sector multipad prototype of the FMD-MCP detector for ALICE. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1998 Дек. 21;419(2-3):654-659. https://doi.org/10.1016/S0168-9002(98)00862-6

Author

Antropov, A. E. ; Fedotov, A. V. ; Feofilov, G. A. ; Izrailov, E. K. ; Kasatkin, V. A. ; Klempt, W. ; Kolojvari, A. A. ; Larin, M. P. ; Lazarev, V. ; Novikov, I. A. ; Stolyarov, O. I. ; Tsimbal, F. A. ; Tulina, T. A. ; Valiev, F. F. ; Vinogradov, L. I. / Sector multipad prototype of the FMD-MCP detector for ALICE. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1998 ; Том 419, № 2-3. стр. 654-659.

BibTeX

@article{747df0a6c4d444269005f0d2ee62da28,
title = "Sector multipad prototype of the FMD-MCP detector for ALICE",
abstract = "We present results of the technology, manufacturing and first tests of a novel MCP-based sector prototype for the forward multiplicity detector for the ALICE experiment at the LHC. The detector provides better than sqrt(M)/M resolution for high multiplicity events, and abou5t 50 ps timing resolution. Two sector MCPs are mounted on a 200 μm ceramics board with the multipad readout integrated with a passive summator. The setup is baked under 300°C and then sealed into a thin wall (200 μm) stainless-steel vacuum sector chamber with a Ti getter keeping a vacuum of 10-5 Torr. A new technology of Al coating is applied in order to reduce the hydrogen leakage through the chamber walls. New multichannel ceramics feedthroughs were also developed for the signal readout and voltage supply. The results of the first in-lab and in-beam tests are discussed.",
author = "Antropov, {A. E.} and Fedotov, {A. V.} and Feofilov, {G. A.} and Izrailov, {E. K.} and Kasatkin, {V. A.} and W. Klempt and Kolojvari, {A. A.} and Larin, {M. P.} and V. Lazarev and Novikov, {I. A.} and Stolyarov, {O. I.} and Tsimbal, {F. A.} and Tulina, {T. A.} and Valiev, {F. F.} and Vinogradov, {L. I.}",
year = "1998",
month = dec,
day = "21",
doi = "10.1016/S0168-9002(98)00862-6",
language = "English",
volume = "419",
pages = "654--659",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",

}

RIS

TY - JOUR

T1 - Sector multipad prototype of the FMD-MCP detector for ALICE

AU - Antropov, A. E.

AU - Fedotov, A. V.

AU - Feofilov, G. A.

AU - Izrailov, E. K.

AU - Kasatkin, V. A.

AU - Klempt, W.

AU - Kolojvari, A. A.

AU - Larin, M. P.

AU - Lazarev, V.

AU - Novikov, I. A.

AU - Stolyarov, O. I.

AU - Tsimbal, F. A.

AU - Tulina, T. A.

AU - Valiev, F. F.

AU - Vinogradov, L. I.

PY - 1998/12/21

Y1 - 1998/12/21

N2 - We present results of the technology, manufacturing and first tests of a novel MCP-based sector prototype for the forward multiplicity detector for the ALICE experiment at the LHC. The detector provides better than sqrt(M)/M resolution for high multiplicity events, and abou5t 50 ps timing resolution. Two sector MCPs are mounted on a 200 μm ceramics board with the multipad readout integrated with a passive summator. The setup is baked under 300°C and then sealed into a thin wall (200 μm) stainless-steel vacuum sector chamber with a Ti getter keeping a vacuum of 10-5 Torr. A new technology of Al coating is applied in order to reduce the hydrogen leakage through the chamber walls. New multichannel ceramics feedthroughs were also developed for the signal readout and voltage supply. The results of the first in-lab and in-beam tests are discussed.

AB - We present results of the technology, manufacturing and first tests of a novel MCP-based sector prototype for the forward multiplicity detector for the ALICE experiment at the LHC. The detector provides better than sqrt(M)/M resolution for high multiplicity events, and abou5t 50 ps timing resolution. Two sector MCPs are mounted on a 200 μm ceramics board with the multipad readout integrated with a passive summator. The setup is baked under 300°C and then sealed into a thin wall (200 μm) stainless-steel vacuum sector chamber with a Ti getter keeping a vacuum of 10-5 Torr. A new technology of Al coating is applied in order to reduce the hydrogen leakage through the chamber walls. New multichannel ceramics feedthroughs were also developed for the signal readout and voltage supply. The results of the first in-lab and in-beam tests are discussed.

UR - http://www.scopus.com/inward/record.url?scp=0032298892&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(98)00862-6

DO - 10.1016/S0168-9002(98)00862-6

M3 - Article

AN - SCOPUS:0032298892

VL - 419

SP - 654

EP - 659

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2-3

ER -