Standard

Relationship of the vibrational temperatures of CO and N2 molecules in a cryogenically cooled flow-through discharge. / Grigor'yan, G. M.; Ionikh, Yu Z.

в: High Temperature, Том 27, № 5, 01.03.1990, стр. 673-677.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{29292b17525441ba84477ee1012d6c19,
title = "Relationship of the vibrational temperatures of CO and N2 molecules in a cryogenically cooled flow-through discharge",
abstract = "The vibrational temperatures of CO and N2 molecules and their distributions over the radius of the discharge vessel are measured in cryogenically cooled flow-through discharges in He-CO, He-N2, He-CO-N2 mixtures. It is shown that in an He-CO-N2 mixture the vibrational temperatures of CO and N2 differ significantly by an amount that is in good agreement with theoretical calculations. The vibrational distribution of the CO molecules in a He-CO-N2 mixture is measured (up to v = 29). It is shown that the populations of the upper vibrational levels are much higher than the Boltzmann values.",
author = "Grigor'yan, {G. M.} and Ionikh, {Yu Z.}",
year = "1990",
month = mar,
day = "1",
language = "English",
volume = "27",
pages = "673--677",
journal = "High Temperature",
issn = "0018-151X",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "5",

}

RIS

TY - JOUR

T1 - Relationship of the vibrational temperatures of CO and N2 molecules in a cryogenically cooled flow-through discharge

AU - Grigor'yan, G. M.

AU - Ionikh, Yu Z.

PY - 1990/3/1

Y1 - 1990/3/1

N2 - The vibrational temperatures of CO and N2 molecules and their distributions over the radius of the discharge vessel are measured in cryogenically cooled flow-through discharges in He-CO, He-N2, He-CO-N2 mixtures. It is shown that in an He-CO-N2 mixture the vibrational temperatures of CO and N2 differ significantly by an amount that is in good agreement with theoretical calculations. The vibrational distribution of the CO molecules in a He-CO-N2 mixture is measured (up to v = 29). It is shown that the populations of the upper vibrational levels are much higher than the Boltzmann values.

AB - The vibrational temperatures of CO and N2 molecules and their distributions over the radius of the discharge vessel are measured in cryogenically cooled flow-through discharges in He-CO, He-N2, He-CO-N2 mixtures. It is shown that in an He-CO-N2 mixture the vibrational temperatures of CO and N2 differ significantly by an amount that is in good agreement with theoretical calculations. The vibrational distribution of the CO molecules in a He-CO-N2 mixture is measured (up to v = 29). It is shown that the populations of the upper vibrational levels are much higher than the Boltzmann values.

UR - http://www.scopus.com/inward/record.url?scp=0025398654&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0025398654

VL - 27

SP - 673

EP - 677

JO - High Temperature

JF - High Temperature

SN - 0018-151X

IS - 5

ER -

ID: 62199164