Standard

Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator. / Marin, V. N.; Trunov, D. N.; Litvin, V. S.; Sadykov, R. A.; Altynbaev, E. V.

в: Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, Том 18, № 4, 01.08.2024, стр. 894–899.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Marin, VN, Trunov, DN, Litvin, VS, Sadykov, RA & Altynbaev, EV 2024, 'Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator', Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, Том. 18, № 4, стр. 894–899. https://doi.org/10.1134/s1027451024700617

APA

Marin, V. N., Trunov, D. N., Litvin, V. S., Sadykov, R. A., & Altynbaev, E. V. (2024). Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator. Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, 18(4), 894–899. https://doi.org/10.1134/s1027451024700617

Vancouver

Marin VN, Trunov DN, Litvin VS, Sadykov RA, Altynbaev EV. Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator. Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques. 2024 Авг. 1;18(4):894–899. https://doi.org/10.1134/s1027451024700617

Author

Marin, V. N. ; Trunov, D. N. ; Litvin, V. S. ; Sadykov, R. A. ; Altynbaev, E. V. / Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator. в: Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques. 2024 ; Том 18, № 4. стр. 894–899.

BibTeX

@article{7e546f602ef54135a0286b0280311cb9,
title = "Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator",
abstract = "Abstract: Neutron scintillation detectors based on ZnS(Ag)/LiF, solid-state photomultipliers, and an organic glass light guide developed at the Institute for Nuclear Research, Russian Academy of Sciences (INR RAS) are successfully used in neutron diffractometers facilities at the INR RAS as a replacement for standard counters based on 3He. These detectors use optical light guides with diffuse reflection, which makes it possible to multiply the recorded signal (up to 95 photoelectrons) in comparison with detectors with wavelength shifting fibers. The article describes two types of bias circuit for silicon photomultipliers. A method of dynamic bias has been proposed, which makes it possible to reduce the recovery time of a silicon photomultiplier and to increase the loading capacity of neutron detectors by a factor of 8. Simulation and comparison of two types of preamplifiers showed an increase in the loading capacity. The new electronics makes it possible to increase the loading capacity of the detectors up to 400 kHz. A circuit for digital control of discrimination thresholds has been developed and described. A new data acquisition system for time-of-flight neutron diffractometers for 80 detectors with the possibility of scaling has been developed.",
keywords = "loading capacity, neutron scintillation detector, time-of-flight data acquisition system",
author = "Marin, {V. N.} and Trunov, {D. N.} and Litvin, {V. S.} and Sadykov, {R. A.} and Altynbaev, {E. V.}",
year = "2024",
month = aug,
day = "1",
doi = "10.1134/s1027451024700617",
language = "English",
volume = "18",
pages = "894–899",
journal = "ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ",
issn = "1027-4510",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "4",

}

RIS

TY - JOUR

T1 - Read-Out System for Thermal Neutron Detectors Based on ZnS(Ag)/LiF Scintillator

AU - Marin, V. N.

AU - Trunov, D. N.

AU - Litvin, V. S.

AU - Sadykov, R. A.

AU - Altynbaev, E. V.

PY - 2024/8/1

Y1 - 2024/8/1

N2 - Abstract: Neutron scintillation detectors based on ZnS(Ag)/LiF, solid-state photomultipliers, and an organic glass light guide developed at the Institute for Nuclear Research, Russian Academy of Sciences (INR RAS) are successfully used in neutron diffractometers facilities at the INR RAS as a replacement for standard counters based on 3He. These detectors use optical light guides with diffuse reflection, which makes it possible to multiply the recorded signal (up to 95 photoelectrons) in comparison with detectors with wavelength shifting fibers. The article describes two types of bias circuit for silicon photomultipliers. A method of dynamic bias has been proposed, which makes it possible to reduce the recovery time of a silicon photomultiplier and to increase the loading capacity of neutron detectors by a factor of 8. Simulation and comparison of two types of preamplifiers showed an increase in the loading capacity. The new electronics makes it possible to increase the loading capacity of the detectors up to 400 kHz. A circuit for digital control of discrimination thresholds has been developed and described. A new data acquisition system for time-of-flight neutron diffractometers for 80 detectors with the possibility of scaling has been developed.

AB - Abstract: Neutron scintillation detectors based on ZnS(Ag)/LiF, solid-state photomultipliers, and an organic glass light guide developed at the Institute for Nuclear Research, Russian Academy of Sciences (INR RAS) are successfully used in neutron diffractometers facilities at the INR RAS as a replacement for standard counters based on 3He. These detectors use optical light guides with diffuse reflection, which makes it possible to multiply the recorded signal (up to 95 photoelectrons) in comparison with detectors with wavelength shifting fibers. The article describes two types of bias circuit for silicon photomultipliers. A method of dynamic bias has been proposed, which makes it possible to reduce the recovery time of a silicon photomultiplier and to increase the loading capacity of neutron detectors by a factor of 8. Simulation and comparison of two types of preamplifiers showed an increase in the loading capacity. The new electronics makes it possible to increase the loading capacity of the detectors up to 400 kHz. A circuit for digital control of discrimination thresholds has been developed and described. A new data acquisition system for time-of-flight neutron diffractometers for 80 detectors with the possibility of scaling has been developed.

KW - loading capacity

KW - neutron scintillation detector

KW - time-of-flight data acquisition system

UR - https://www.mendeley.com/catalogue/c7d0c295-e8a6-328f-a165-536e90026270/

U2 - 10.1134/s1027451024700617

DO - 10.1134/s1027451024700617

M3 - Article

VL - 18

SP - 894

EP - 899

JO - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

JF - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

SN - 1027-4510

IS - 4

ER -

ID: 126738420