Standard

Quality control of B-lines analysis in stress Echo 2020. / Scali, Maria Chiara; Ciampi, Quirino; Picano, Eugenio; Bossone, Eduardo; Ferrara, Francesco; Citro, Rodolfo; Colonna, Paolo; Costantino, Marco Fabio; Cortigiani, Lauro; Andrea, Antonello D.; Severino, Sergio; Dodi, Claudio; Gaibazzi, Nicola; Galderisi, Maurizio; Barbieri, Andrea; Monte, Ines; Mori, Fabio; Reisenhofer, Barbara; Re, Federica; Rigo, Fausto; Trambaiolo, Paolo; Amor, Miguel; Lowenstein, Jorge; Merlo, Pablo Martin; Daros, Clarissa Borguezan; De Castro E Silva Pretto, José Luis; Miglioranza, Marcelo Haertel; Torres, Marco A.R.; De Azevedo Bellagamba, Clarissa Carmona; Chaves, Daniel Quesada; Simova, Iana; Varga, Albert; Čelutkiene, Jelena; Kasprzak, Jaroslaw D.; Wierzbowska-Drabik, Karina; Lipiec, Piotr; Weiner-Mik, Paulina; Szymczyk, Eva; Wdowiak-Okrojek, Katarzyna; Djordjevic-Dikic, Ana; Dekleva, Milica; Stankovic, Ivan; Neskovic, Aleksandar N.; Zagatina, Angela; Di Salvo, Giovanni; Perez, Julio E.; Camarozano, Ana Cristina; Corciu, Anca Irina; Boshchenko, Alla; Lattanzi, Fabio.

в: Cardiovascular Ultrasound, Том 16, № 1, 20, 25.09.2018.

Результаты исследований: Научные публикации в периодических изданияхОбзорная статьяРецензирование

Harvard

Scali, MC, Ciampi, Q, Picano, E, Bossone, E, Ferrara, F, Citro, R, Colonna, P, Costantino, MF, Cortigiani, L, Andrea, AD, Severino, S, Dodi, C, Gaibazzi, N, Galderisi, M, Barbieri, A, Monte, I, Mori, F, Reisenhofer, B, Re, F, Rigo, F, Trambaiolo, P, Amor, M, Lowenstein, J, Merlo, PM, Daros, CB, De Castro E Silva Pretto, JL, Miglioranza, MH, Torres, MAR, De Azevedo Bellagamba, CC, Chaves, DQ, Simova, I, Varga, A, Čelutkiene, J, Kasprzak, JD, Wierzbowska-Drabik, K, Lipiec, P, Weiner-Mik, P, Szymczyk, E, Wdowiak-Okrojek, K, Djordjevic-Dikic, A, Dekleva, M, Stankovic, I, Neskovic, AN, Zagatina, A, Di Salvo, G, Perez, JE, Camarozano, AC, Corciu, AI, Boshchenko, A & Lattanzi, F 2018, 'Quality control of B-lines analysis in stress Echo 2020', Cardiovascular Ultrasound, Том. 16, № 1, 20. https://doi.org/10.1186/s12947-018-0138-7

APA

Scali, M. C., Ciampi, Q., Picano, E., Bossone, E., Ferrara, F., Citro, R., Colonna, P., Costantino, M. F., Cortigiani, L., Andrea, A. D., Severino, S., Dodi, C., Gaibazzi, N., Galderisi, M., Barbieri, A., Monte, I., Mori, F., Reisenhofer, B., Re, F., ... Lattanzi, F. (2018). Quality control of B-lines analysis in stress Echo 2020. Cardiovascular Ultrasound, 16(1), [20]. https://doi.org/10.1186/s12947-018-0138-7

Vancouver

Scali MC, Ciampi Q, Picano E, Bossone E, Ferrara F, Citro R и пр. Quality control of B-lines analysis in stress Echo 2020. Cardiovascular Ultrasound. 2018 Сент. 25;16(1). 20. https://doi.org/10.1186/s12947-018-0138-7

Author

Scali, Maria Chiara ; Ciampi, Quirino ; Picano, Eugenio ; Bossone, Eduardo ; Ferrara, Francesco ; Citro, Rodolfo ; Colonna, Paolo ; Costantino, Marco Fabio ; Cortigiani, Lauro ; Andrea, Antonello D. ; Severino, Sergio ; Dodi, Claudio ; Gaibazzi, Nicola ; Galderisi, Maurizio ; Barbieri, Andrea ; Monte, Ines ; Mori, Fabio ; Reisenhofer, Barbara ; Re, Federica ; Rigo, Fausto ; Trambaiolo, Paolo ; Amor, Miguel ; Lowenstein, Jorge ; Merlo, Pablo Martin ; Daros, Clarissa Borguezan ; De Castro E Silva Pretto, José Luis ; Miglioranza, Marcelo Haertel ; Torres, Marco A.R. ; De Azevedo Bellagamba, Clarissa Carmona ; Chaves, Daniel Quesada ; Simova, Iana ; Varga, Albert ; Čelutkiene, Jelena ; Kasprzak, Jaroslaw D. ; Wierzbowska-Drabik, Karina ; Lipiec, Piotr ; Weiner-Mik, Paulina ; Szymczyk, Eva ; Wdowiak-Okrojek, Katarzyna ; Djordjevic-Dikic, Ana ; Dekleva, Milica ; Stankovic, Ivan ; Neskovic, Aleksandar N. ; Zagatina, Angela ; Di Salvo, Giovanni ; Perez, Julio E. ; Camarozano, Ana Cristina ; Corciu, Anca Irina ; Boshchenko, Alla ; Lattanzi, Fabio. / Quality control of B-lines analysis in stress Echo 2020. в: Cardiovascular Ultrasound. 2018 ; Том 16, № 1.

BibTeX

@article{327e24a4a2974ba9bdbd894a8c8ec9c8,
title = "Quality control of B-lines analysis in stress Echo 2020",
abstract = "Background: The effectiveness trial {"}Stress echo (SE) 2020{"} evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose: To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods: 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module (http://se2020.altervista.org). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results: All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p <.01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p <.01). Conclusions: Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.",
keywords = "Certification, Lung comets, Quality control, Stress echocardiography, Wall motion",
author = "Scali, {Maria Chiara} and Quirino Ciampi and Eugenio Picano and Eduardo Bossone and Francesco Ferrara and Rodolfo Citro and Paolo Colonna and Costantino, {Marco Fabio} and Lauro Cortigiani and Andrea, {Antonello D.} and Sergio Severino and Claudio Dodi and Nicola Gaibazzi and Maurizio Galderisi and Andrea Barbieri and Ines Monte and Fabio Mori and Barbara Reisenhofer and Federica Re and Fausto Rigo and Paolo Trambaiolo and Miguel Amor and Jorge Lowenstein and Merlo, {Pablo Martin} and Daros, {Clarissa Borguezan} and {De Castro E Silva Pretto}, {Jos{\'e} Luis} and Miglioranza, {Marcelo Haertel} and Torres, {Marco A.R.} and {De Azevedo Bellagamba}, {Clarissa Carmona} and Chaves, {Daniel Quesada} and Iana Simova and Albert Varga and Jelena {\v C}elutkiene and Kasprzak, {Jaroslaw D.} and Karina Wierzbowska-Drabik and Piotr Lipiec and Paulina Weiner-Mik and Eva Szymczyk and Katarzyna Wdowiak-Okrojek and Ana Djordjevic-Dikic and Milica Dekleva and Ivan Stankovic and Neskovic, {Aleksandar N.} and Angela Zagatina and {Di Salvo}, Giovanni and Perez, {Julio E.} and Camarozano, {Ana Cristina} and Corciu, {Anca Irina} and Alla Boshchenko and Fabio Lattanzi",
year = "2018",
month = sep,
day = "25",
doi = "10.1186/s12947-018-0138-7",
language = "English",
volume = "16",
journal = "Cardiovascular Ultrasound",
issn = "1476-7120",
publisher = "BioMed Central Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Quality control of B-lines analysis in stress Echo 2020

AU - Scali, Maria Chiara

AU - Ciampi, Quirino

AU - Picano, Eugenio

AU - Bossone, Eduardo

AU - Ferrara, Francesco

AU - Citro, Rodolfo

AU - Colonna, Paolo

AU - Costantino, Marco Fabio

AU - Cortigiani, Lauro

AU - Andrea, Antonello D.

AU - Severino, Sergio

AU - Dodi, Claudio

AU - Gaibazzi, Nicola

AU - Galderisi, Maurizio

AU - Barbieri, Andrea

AU - Monte, Ines

AU - Mori, Fabio

AU - Reisenhofer, Barbara

AU - Re, Federica

AU - Rigo, Fausto

AU - Trambaiolo, Paolo

AU - Amor, Miguel

AU - Lowenstein, Jorge

AU - Merlo, Pablo Martin

AU - Daros, Clarissa Borguezan

AU - De Castro E Silva Pretto, José Luis

AU - Miglioranza, Marcelo Haertel

AU - Torres, Marco A.R.

AU - De Azevedo Bellagamba, Clarissa Carmona

AU - Chaves, Daniel Quesada

AU - Simova, Iana

AU - Varga, Albert

AU - Čelutkiene, Jelena

AU - Kasprzak, Jaroslaw D.

AU - Wierzbowska-Drabik, Karina

AU - Lipiec, Piotr

AU - Weiner-Mik, Paulina

AU - Szymczyk, Eva

AU - Wdowiak-Okrojek, Katarzyna

AU - Djordjevic-Dikic, Ana

AU - Dekleva, Milica

AU - Stankovic, Ivan

AU - Neskovic, Aleksandar N.

AU - Zagatina, Angela

AU - Di Salvo, Giovanni

AU - Perez, Julio E.

AU - Camarozano, Ana Cristina

AU - Corciu, Anca Irina

AU - Boshchenko, Alla

AU - Lattanzi, Fabio

PY - 2018/9/25

Y1 - 2018/9/25

N2 - Background: The effectiveness trial "Stress echo (SE) 2020" evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose: To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods: 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module (http://se2020.altervista.org). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results: All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p <.01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p <.01). Conclusions: Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.

AB - Background: The effectiveness trial "Stress echo (SE) 2020" evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose: To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods: 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module (http://se2020.altervista.org). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results: All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p <.01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p <.01). Conclusions: Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.

KW - Certification

KW - Lung comets

KW - Quality control

KW - Stress echocardiography

KW - Wall motion

UR - http://www.scopus.com/inward/record.url?scp=85053845849&partnerID=8YFLogxK

U2 - 10.1186/s12947-018-0138-7

DO - 10.1186/s12947-018-0138-7

M3 - Review article

C2 - 30249305

AN - SCOPUS:85053845849

VL - 16

JO - Cardiovascular Ultrasound

JF - Cardiovascular Ultrasound

SN - 1476-7120

IS - 1

M1 - 20

ER -

ID: 43611500