Standard

Potassium-selective conductometric sensor. / Shvarev, Alexey E.; Rantsan, Dmitriy A.; Mikhelson, Konstantin N.

в: Sensors and Actuators, B: Chemical, Том 76, № 1-3, 01.06.2001, стр. 500-505.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Shvarev, AE, Rantsan, DA & Mikhelson, KN 2001, 'Potassium-selective conductometric sensor', Sensors and Actuators, B: Chemical, Том. 76, № 1-3, стр. 500-505. https://doi.org/10.1016/S0925-4005(01)00601-3

APA

Shvarev, A. E., Rantsan, D. A., & Mikhelson, K. N. (2001). Potassium-selective conductometric sensor. Sensors and Actuators, B: Chemical, 76(1-3), 500-505. https://doi.org/10.1016/S0925-4005(01)00601-3

Vancouver

Shvarev AE, Rantsan DA, Mikhelson KN. Potassium-selective conductometric sensor. Sensors and Actuators, B: Chemical. 2001 Июнь 1;76(1-3):500-505. https://doi.org/10.1016/S0925-4005(01)00601-3

Author

Shvarev, Alexey E. ; Rantsan, Dmitriy A. ; Mikhelson, Konstantin N. / Potassium-selective conductometric sensor. в: Sensors and Actuators, B: Chemical. 2001 ; Том 76, № 1-3. стр. 500-505.

BibTeX

@article{f94b2c069ffc471fb3a73d93f696d030,
title = "Potassium-selective conductometric sensor",
abstract = "Potassium-selective membranes known as sensing modules for potentiometric ion-selective electrodes are studied in ac-impedance mode. It is shown that the bulk resistance of thin (20-250 μm) membranes depends on the composition of aqueous bathing solution. The results are explained in terms of surface conductivity in space-charge region, in the vicinity of water microdroplets in membranes. A planar potassium-selective sensor with a conductometric signal is proposed.",
keywords = "Conductometric sensor, Potassium, Solvent-polymeric membrane, Valinomycin",
author = "Shvarev, {Alexey E.} and Rantsan, {Dmitriy A.} and Mikhelson, {Konstantin N.}",
year = "2001",
month = jun,
day = "1",
doi = "10.1016/S0925-4005(01)00601-3",
language = "English",
volume = "76",
pages = "500--505",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "1-3",

}

RIS

TY - JOUR

T1 - Potassium-selective conductometric sensor

AU - Shvarev, Alexey E.

AU - Rantsan, Dmitriy A.

AU - Mikhelson, Konstantin N.

PY - 2001/6/1

Y1 - 2001/6/1

N2 - Potassium-selective membranes known as sensing modules for potentiometric ion-selective electrodes are studied in ac-impedance mode. It is shown that the bulk resistance of thin (20-250 μm) membranes depends on the composition of aqueous bathing solution. The results are explained in terms of surface conductivity in space-charge region, in the vicinity of water microdroplets in membranes. A planar potassium-selective sensor with a conductometric signal is proposed.

AB - Potassium-selective membranes known as sensing modules for potentiometric ion-selective electrodes are studied in ac-impedance mode. It is shown that the bulk resistance of thin (20-250 μm) membranes depends on the composition of aqueous bathing solution. The results are explained in terms of surface conductivity in space-charge region, in the vicinity of water microdroplets in membranes. A planar potassium-selective sensor with a conductometric signal is proposed.

KW - Conductometric sensor

KW - Potassium

KW - Solvent-polymeric membrane

KW - Valinomycin

UR - http://www.scopus.com/inward/record.url?scp=0035369429&partnerID=8YFLogxK

U2 - 10.1016/S0925-4005(01)00601-3

DO - 10.1016/S0925-4005(01)00601-3

M3 - Article

AN - SCOPUS:0035369429

VL - 76

SP - 500

EP - 505

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 1-3

ER -

ID: 92359657