Standard

Peculiarities of the potentiometric response of ISEs with membranes containing two neutral ionophores and an excess of ion-exchanger: Experiment and modeling. / Керестень, Валентина Максимовна; Попов, Андрей Юрьевич; Михельсон, Константин Николаевич.

в: Sensors and Actuators, B: Chemical, Том 417, 136090, 01.10.2024.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{f831175d07924f758c03749f1a02ec67,
title = "Peculiarities of the potentiometric response of ISEs with membranes containing two neutral ionophores and an excess of ion-exchanger: Experiment and modeling",
abstract = "The potentiometric response of ion-selective electrodes (ISEs) with membranes simultaneously containing two ionophores: valinomycin and lithium ionophore Li VIII, as well as the cation exchanger potassium tetrakis(p-Cl-phenyl) borate in different concentrations is studied in KCl, LiCl and KCl + LiCl solutions. It is shown that ISEs with a membrane containing an excess of ionophores over the ion-exchanger provide Nernstian response to K+ and to Li+ ions. However, membranes with an excess of the ion-exchanger over valinomycin show Nernstian response to K+ only in mixed KCl + LiCl solutions with constant ratios of the concentrations of these electrolytes. On the contrary, the response to Li+ is obtained both in mixed and pure LiCl solutions. The results are semi-quantitatively explained using a simple mathematical model and respective computer simulation.",
keywords = "Computer simulations, Excess of ion-exchanger, Ion-selective electrodes, Potentiometric measurements, Two ionophores in membrane",
author = "Керестень, {Валентина Максимовна} and Попов, {Андрей Юрьевич} and Михельсон, {Константин Николаевич}",
year = "2024",
month = oct,
day = "1",
doi = "10.1016/j.snb.2024.136090",
language = "English",
volume = "417",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Peculiarities of the potentiometric response of ISEs with membranes containing two neutral ionophores and an excess of ion-exchanger: Experiment and modeling

AU - Керестень, Валентина Максимовна

AU - Попов, Андрей Юрьевич

AU - Михельсон, Константин Николаевич

PY - 2024/10/1

Y1 - 2024/10/1

N2 - The potentiometric response of ion-selective electrodes (ISEs) with membranes simultaneously containing two ionophores: valinomycin and lithium ionophore Li VIII, as well as the cation exchanger potassium tetrakis(p-Cl-phenyl) borate in different concentrations is studied in KCl, LiCl and KCl + LiCl solutions. It is shown that ISEs with a membrane containing an excess of ionophores over the ion-exchanger provide Nernstian response to K+ and to Li+ ions. However, membranes with an excess of the ion-exchanger over valinomycin show Nernstian response to K+ only in mixed KCl + LiCl solutions with constant ratios of the concentrations of these electrolytes. On the contrary, the response to Li+ is obtained both in mixed and pure LiCl solutions. The results are semi-quantitatively explained using a simple mathematical model and respective computer simulation.

AB - The potentiometric response of ion-selective electrodes (ISEs) with membranes simultaneously containing two ionophores: valinomycin and lithium ionophore Li VIII, as well as the cation exchanger potassium tetrakis(p-Cl-phenyl) borate in different concentrations is studied in KCl, LiCl and KCl + LiCl solutions. It is shown that ISEs with a membrane containing an excess of ionophores over the ion-exchanger provide Nernstian response to K+ and to Li+ ions. However, membranes with an excess of the ion-exchanger over valinomycin show Nernstian response to K+ only in mixed KCl + LiCl solutions with constant ratios of the concentrations of these electrolytes. On the contrary, the response to Li+ is obtained both in mixed and pure LiCl solutions. The results are semi-quantitatively explained using a simple mathematical model and respective computer simulation.

KW - Computer simulations

KW - Excess of ion-exchanger

KW - Ion-selective electrodes

KW - Potentiometric measurements

KW - Two ionophores in membrane

UR - https://www.mendeley.com/catalogue/213da933-5fdf-3440-92ef-e22121a5de61/

U2 - 10.1016/j.snb.2024.136090

DO - 10.1016/j.snb.2024.136090

M3 - Article

VL - 417

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

M1 - 136090

ER -

ID: 120307695