Standard

Oxygen Reactions at the Interface of Nonstoichiometric Fluorides LaF 3 and CeF3 with Chemically Modified Electrodes. / Urchukova, M. M.; Kot, S. A.; Turaeva, M. S.; Murin, I. V.

в: Russian Journal of Electrochemistry, Том 39, № 5, 05.2003, стр. 575-580.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Urchukova, MM, Kot, SA, Turaeva, MS & Murin, IV 2003, 'Oxygen Reactions at the Interface of Nonstoichiometric Fluorides LaF 3 and CeF3 with Chemically Modified Electrodes', Russian Journal of Electrochemistry, Том. 39, № 5, стр. 575-580. https://doi.org/10.1023/A:1023893330488

APA

Vancouver

Author

Urchukova, M. M. ; Kot, S. A. ; Turaeva, M. S. ; Murin, I. V. / Oxygen Reactions at the Interface of Nonstoichiometric Fluorides LaF 3 and CeF3 with Chemically Modified Electrodes. в: Russian Journal of Electrochemistry. 2003 ; Том 39, № 5. стр. 575-580.

BibTeX

@article{ee37860664c640ffa3c06050381662cd,
title = "Oxygen Reactions at the Interface of Nonstoichiometric Fluorides LaF 3 and CeF3 with Chemically Modified Electrodes",
abstract = "The oxygen reaction at the interface LaF3(CeF 3)|electrode, O2(g) is studied in air on Pt and C electrodes and electrodes modified by supported oxides of Co, Sr, and/or La on C, Si, or Pt substrates. The experimental methods used are voltammetry with a linear potential change and stripping voltammetry and cyclic voltammetry. The voltammetric response is dependent on the nature of solid electrolyte and electrode, the balance between the substrate and active agent, and on the conditions of thermal treatment of electrodes. Mobile oxygen forms are discovered at interfaces CeF3|C (CoxOy), O 2 ([C] : [Co] = 1 : 10, 1 : 20); CeF3|C (Co xOy), O2 ([C] : [Co] = 1: 10); and CeF 3|Pt (CoxOy), O2 ([Pt] : [Co] = 1 : 40). The peak current Ipa in the anodic curves increases with extending the limit of cathodic potential scan Erc. The peak current Ipc in the cathodic curves increases with extending the limit of anodic potential scan Era.",
author = "Urchukova, {M. M.} and Kot, {S. A.} and Turaeva, {M. S.} and Murin, {I. V.}",
year = "2003",
month = may,
doi = "10.1023/A:1023893330488",
language = "English",
volume = "39",
pages = "575--580",
journal = "Russian Journal of Electrochemistry",
issn = "1023-1935",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "5",

}

RIS

TY - JOUR

T1 - Oxygen Reactions at the Interface of Nonstoichiometric Fluorides LaF 3 and CeF3 with Chemically Modified Electrodes

AU - Urchukova, M. M.

AU - Kot, S. A.

AU - Turaeva, M. S.

AU - Murin, I. V.

PY - 2003/5

Y1 - 2003/5

N2 - The oxygen reaction at the interface LaF3(CeF 3)|electrode, O2(g) is studied in air on Pt and C electrodes and electrodes modified by supported oxides of Co, Sr, and/or La on C, Si, or Pt substrates. The experimental methods used are voltammetry with a linear potential change and stripping voltammetry and cyclic voltammetry. The voltammetric response is dependent on the nature of solid electrolyte and electrode, the balance between the substrate and active agent, and on the conditions of thermal treatment of electrodes. Mobile oxygen forms are discovered at interfaces CeF3|C (CoxOy), O 2 ([C] : [Co] = 1 : 10, 1 : 20); CeF3|C (Co xOy), O2 ([C] : [Co] = 1: 10); and CeF 3|Pt (CoxOy), O2 ([Pt] : [Co] = 1 : 40). The peak current Ipa in the anodic curves increases with extending the limit of cathodic potential scan Erc. The peak current Ipc in the cathodic curves increases with extending the limit of anodic potential scan Era.

AB - The oxygen reaction at the interface LaF3(CeF 3)|electrode, O2(g) is studied in air on Pt and C electrodes and electrodes modified by supported oxides of Co, Sr, and/or La on C, Si, or Pt substrates. The experimental methods used are voltammetry with a linear potential change and stripping voltammetry and cyclic voltammetry. The voltammetric response is dependent on the nature of solid electrolyte and electrode, the balance between the substrate and active agent, and on the conditions of thermal treatment of electrodes. Mobile oxygen forms are discovered at interfaces CeF3|C (CoxOy), O 2 ([C] : [Co] = 1 : 10, 1 : 20); CeF3|C (Co xOy), O2 ([C] : [Co] = 1: 10); and CeF 3|Pt (CoxOy), O2 ([Pt] : [Co] = 1 : 40). The peak current Ipa in the anodic curves increases with extending the limit of cathodic potential scan Erc. The peak current Ipc in the cathodic curves increases with extending the limit of anodic potential scan Era.

UR - http://www.scopus.com/inward/record.url?scp=1642573355&partnerID=8YFLogxK

U2 - 10.1023/A:1023893330488

DO - 10.1023/A:1023893330488

M3 - Article

AN - SCOPUS:1642573355

VL - 39

SP - 575

EP - 580

JO - Russian Journal of Electrochemistry

JF - Russian Journal of Electrochemistry

SN - 1023-1935

IS - 5

ER -

ID: 88002523