Operation rates of different schemes of continuous chromatomembrane gas extraction. / Rodinkov, O. V.; Moskvin, L. N.; Maiorova, N. A.

в: Journal of Analytical Chemistry, Том 60, № 8, 01.08.2005, стр. 727-731.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

Rodinkov, O. V. ; Moskvin, L. N. ; Maiorova, N. A. / Operation rates of different schemes of continuous chromatomembrane gas extraction. в: Journal of Analytical Chemistry. 2005 ; Том 60, № 8. стр. 727-731.

BibTeX

@article{c1c7785fd87d44a69cb45b29cc32ef9a,
title = "Operation rates of different schemes of continuous chromatomembrane gas extraction",
abstract = "The operation rates of different schemes of chromatomembrane gas extraction were compared. It was demonstrated that the cocurrent scheme (when the phases move in one direction) exhibits the highest rate, the two-dimensional scheme (motion of the phases at an angle of 90°) ranks below, and the countercurrent scheme (the phases move in opposite directions) exhibits the lowest rate.",
author = "Rodinkov, {O. V.} and Moskvin, {L. N.} and Maiorova, {N. A.}",
year = "2005",
month = aug,
day = "1",
doi = "10.1007/s10809-005-0171-1",
language = "English",
volume = "60",
pages = "727--731",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "8",

}

RIS

TY - JOUR

T1 - Operation rates of different schemes of continuous chromatomembrane gas extraction

AU - Rodinkov, O. V.

AU - Moskvin, L. N.

AU - Maiorova, N. A.

PY - 2005/8/1

Y1 - 2005/8/1

N2 - The operation rates of different schemes of chromatomembrane gas extraction were compared. It was demonstrated that the cocurrent scheme (when the phases move in one direction) exhibits the highest rate, the two-dimensional scheme (motion of the phases at an angle of 90°) ranks below, and the countercurrent scheme (the phases move in opposite directions) exhibits the lowest rate.

AB - The operation rates of different schemes of chromatomembrane gas extraction were compared. It was demonstrated that the cocurrent scheme (when the phases move in one direction) exhibits the highest rate, the two-dimensional scheme (motion of the phases at an angle of 90°) ranks below, and the countercurrent scheme (the phases move in opposite directions) exhibits the lowest rate.

UR - http://www.scopus.com/inward/record.url?scp=23944457823&partnerID=8YFLogxK

U2 - 10.1007/s10809-005-0171-1

DO - 10.1007/s10809-005-0171-1

M3 - Article

AN - SCOPUS:23944457823

VL - 60

SP - 727

EP - 731

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 8

ER -

ID: 49997627