Standard
Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164. / Eliseev, S.; Roux, C.; Blaum, K.; Block, M.; Droese, C.; Herfurth, F.; Kretzschmar, M.; Krivoruchenko, M. I.; Minaya Ramirez, E.; Novikov, Yu N.; Schweikhard, L.; Shabaev, V. M.; Šimkovic, F.; Tupitsyn, I. I.; Zuber, K.; Zubova, N. A.
в:
Physical Review Letters, Том 107, № 15, 152501, 07.10.2011.
Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Harvard
Eliseev, S, Roux, C, Blaum, K, Block, M, Droese, C, Herfurth, F, Kretzschmar, M, Krivoruchenko, MI, Minaya Ramirez, E
, Novikov, YN, Schweikhard, L
, Shabaev, VM, Šimkovic, F
, Tupitsyn, II, Zuber, K
& Zubova, NA 2011, '
Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164',
Physical Review Letters, Том. 107, № 15, 152501.
https://doi.org/10.1103/PhysRevLett.107.152501
APA
Eliseev, S., Roux, C., Blaum, K., Block, M., Droese, C., Herfurth, F., Kretzschmar, M., Krivoruchenko, M. I., Minaya Ramirez, E.
, Novikov, Y. N., Schweikhard, L.
, Shabaev, V. M., Šimkovic, F.
, Tupitsyn, I. I., Zuber, K.
, & Zubova, N. A. (2011).
Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164.
Physical Review Letters,
107(15), [152501].
https://doi.org/10.1103/PhysRevLett.107.152501
Vancouver
Author
Eliseev, S. ; Roux, C. ; Blaum, K. ; Block, M. ; Droese, C. ; Herfurth, F. ; Kretzschmar, M. ; Krivoruchenko, M. I. ; Minaya Ramirez, E.
; Novikov, Yu N. ; Schweikhard, L.
; Shabaev, V. M. ; Šimkovic, F.
; Tupitsyn, I. I. ; Zuber, K.
; Zubova, N. A. /
Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164. в:
Physical Review Letters. 2011 ; Том 107, № 15.
BibTeX
@article{74237659b8bb4cba96ba0648bdeb9dcb,
title = "Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164",
abstract = "The theory of octupolar-excitation ion-cyclotron-resonance mass spectrometry is presented which predicts an increase of up to several orders of magnitude in resolving power under certain conditions. The new method has been applied for a direct Penning-trap mass-ratio determination of the Er164-Dy164 mass doublet. Er164 is a candidate for the search for neutrinoless double-electron capture. However, the measured Q value of 25.07(12) keV results in a half-life of 1030 years for a 1 eV Majorana-neutrino mass.",
author = "S. Eliseev and C. Roux and K. Blaum and M. Block and C. Droese and F. Herfurth and M. Kretzschmar and Krivoruchenko, {M. I.} and {Minaya Ramirez}, E. and Novikov, {Yu N.} and L. Schweikhard and Shabaev, {V. M.} and F. {\v S}imkovic and Tupitsyn, {I. I.} and K. Zuber and Zubova, {N. A.}",
year = "2011",
month = oct,
day = "7",
doi = "10.1103/PhysRevLett.107.152501",
language = "English",
volume = "107",
journal = "Physical Review Letters",
issn = "0031-9007",
publisher = "American Physical Society",
number = "15",
}
RIS
TY - JOUR
T1 - Octupolar-excitation Penning-trap mass spectrometry for Q-value measurement of double-electron capture in Er164
AU - Eliseev, S.
AU - Roux, C.
AU - Blaum, K.
AU - Block, M.
AU - Droese, C.
AU - Herfurth, F.
AU - Kretzschmar, M.
AU - Krivoruchenko, M. I.
AU - Minaya Ramirez, E.
AU - Novikov, Yu N.
AU - Schweikhard, L.
AU - Shabaev, V. M.
AU - Šimkovic, F.
AU - Tupitsyn, I. I.
AU - Zuber, K.
AU - Zubova, N. A.
PY - 2011/10/7
Y1 - 2011/10/7
N2 - The theory of octupolar-excitation ion-cyclotron-resonance mass spectrometry is presented which predicts an increase of up to several orders of magnitude in resolving power under certain conditions. The new method has been applied for a direct Penning-trap mass-ratio determination of the Er164-Dy164 mass doublet. Er164 is a candidate for the search for neutrinoless double-electron capture. However, the measured Q value of 25.07(12) keV results in a half-life of 1030 years for a 1 eV Majorana-neutrino mass.
AB - The theory of octupolar-excitation ion-cyclotron-resonance mass spectrometry is presented which predicts an increase of up to several orders of magnitude in resolving power under certain conditions. The new method has been applied for a direct Penning-trap mass-ratio determination of the Er164-Dy164 mass doublet. Er164 is a candidate for the search for neutrinoless double-electron capture. However, the measured Q value of 25.07(12) keV results in a half-life of 1030 years for a 1 eV Majorana-neutrino mass.
UR - http://www.scopus.com/inward/record.url?scp=80053594468&partnerID=8YFLogxK
U2 - 10.1103/PhysRevLett.107.152501
DO - 10.1103/PhysRevLett.107.152501
M3 - Article
AN - SCOPUS:80053594468
VL - 107
JO - Physical Review Letters
JF - Physical Review Letters
SN - 0031-9007
IS - 15
M1 - 152501
ER -