Standard

NEXAFS C1s-spectra apparatus distortion study. / Mingaleva, A. E.; Petrova, O. V.; Sivkov, D. V.; Shomysov, N. N.; Nekipelov, S. V.; Skandakov, R. N.; Sivkov, V. N.

в: Journal of Physics: Conference Series, Том 1124, № 5, 051035, 01.01.2018.

Результаты исследований: Научные публикации в периодических изданияхстатья в журнале по материалам конференцииРецензирование

Harvard

Mingaleva, AE, Petrova, OV, Sivkov, DV, Shomysov, NN, Nekipelov, SV, Skandakov, RN & Sivkov, VN 2018, 'NEXAFS C1s-spectra apparatus distortion study', Journal of Physics: Conference Series, Том. 1124, № 5, 051035. https://doi.org/10.1088/1742-6596/1124/5/051035

APA

Mingaleva, A. E., Petrova, O. V., Sivkov, D. V., Shomysov, N. N., Nekipelov, S. V., Skandakov, R. N., & Sivkov, V. N. (2018). NEXAFS C1s-spectra apparatus distortion study. Journal of Physics: Conference Series, 1124(5), [051035]. https://doi.org/10.1088/1742-6596/1124/5/051035

Vancouver

Mingaleva AE, Petrova OV, Sivkov DV, Shomysov NN, Nekipelov SV, Skandakov RN и пр. NEXAFS C1s-spectra apparatus distortion study. Journal of Physics: Conference Series. 2018 Янв. 1;1124(5). 051035. https://doi.org/10.1088/1742-6596/1124/5/051035

Author

Mingaleva, A. E. ; Petrova, O. V. ; Sivkov, D. V. ; Shomysov, N. N. ; Nekipelov, S. V. ; Skandakov, R. N. ; Sivkov, V. N. / NEXAFS C1s-spectra apparatus distortion study. в: Journal of Physics: Conference Series. 2018 ; Том 1124, № 5.

BibTeX

@article{88e0665d7a8046d1ac06aa046dc5d3f0,
title = "NEXAFS C1s-spectra apparatus distortion study",
abstract = " The results of the comparison of TEY and transmission methods of X-ray absorption spectra measurements as well as {"}thickness effect{"} modeling in the linear absorption coefficient spectral dependences of the C 60 -films in the NEXAFS C1s-spectra are represented. The calculations were performed with using linear absorption coefficient spectra obtained in TEY mode as the true (undistorted) data. The modelling results are in good agreement with the experiment. All NEXAFS C1s-spectra was carried out at the BESSY II using synchrotron radiation from the Russian-German dipole beamline. ",
author = "Mingaleva, {A. E.} and Petrova, {O. V.} and Sivkov, {D. V.} and Shomysov, {N. N.} and Nekipelov, {S. V.} and Skandakov, {R. N.} and Sivkov, {V. N.}",
year = "2018",
month = jan,
day = "1",
doi = "10.1088/1742-6596/1124/5/051035",
language = "English",
volume = "1124",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "5",
note = "5th International School and Conference on Optoelectronics, Photonics, Engineering and Nanostructures, Saint Petersburg OPEN 2018 ; Conference date: 02-04-2018 Through 05-04-2018",
url = "http://spbopen2018.spbau.com/, http://ru.spbopen.spbau.com/",

}

RIS

TY - JOUR

T1 - NEXAFS C1s-spectra apparatus distortion study

AU - Mingaleva, A. E.

AU - Petrova, O. V.

AU - Sivkov, D. V.

AU - Shomysov, N. N.

AU - Nekipelov, S. V.

AU - Skandakov, R. N.

AU - Sivkov, V. N.

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The results of the comparison of TEY and transmission methods of X-ray absorption spectra measurements as well as "thickness effect" modeling in the linear absorption coefficient spectral dependences of the C 60 -films in the NEXAFS C1s-spectra are represented. The calculations were performed with using linear absorption coefficient spectra obtained in TEY mode as the true (undistorted) data. The modelling results are in good agreement with the experiment. All NEXAFS C1s-spectra was carried out at the BESSY II using synchrotron radiation from the Russian-German dipole beamline.

AB - The results of the comparison of TEY and transmission methods of X-ray absorption spectra measurements as well as "thickness effect" modeling in the linear absorption coefficient spectral dependences of the C 60 -films in the NEXAFS C1s-spectra are represented. The calculations were performed with using linear absorption coefficient spectra obtained in TEY mode as the true (undistorted) data. The modelling results are in good agreement with the experiment. All NEXAFS C1s-spectra was carried out at the BESSY II using synchrotron radiation from the Russian-German dipole beamline.

UR - http://www.scopus.com/inward/record.url?scp=85060919711&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/1124/5/051035

DO - 10.1088/1742-6596/1124/5/051035

M3 - Conference article

AN - SCOPUS:85060919711

VL - 1124

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 5

M1 - 051035

T2 - 5th International School and Conference on Optoelectronics, Photonics, Engineering and Nanostructures, Saint Petersburg OPEN 2018

Y2 - 2 April 2018 through 5 April 2018

ER -

ID: 43103703