Результаты исследований: Научные публикации в периодических изданиях › статья в журнале по материалам конференции › Рецензирование
Neutron multimonochromator-bipolarizer based on magnetic multilayer Fe/Co and new scheme for the total neutron polarization analysis. / Syromyatnikov, V. G.; Zaw Lin, Kyaw.
в: Journal of Physics: Conference Series, Том 862, № 1, 012016, 20.06.2017.Результаты исследований: Научные публикации в периодических изданиях › статья в журнале по материалам конференции › Рецензирование
}
TY - JOUR
T1 - Neutron multimonochromator-bipolarizer based on magnetic multilayer Fe/Co and new scheme for the total neutron polarization analysis
AU - Syromyatnikov, V. G.
AU - Zaw Lin, Kyaw
N1 - Publisher Copyright: © Published under licence by IOP Publishing Ltd.
PY - 2017/6/20
Y1 - 2017/6/20
N2 - In this paper, we present a new neutron-optical element, Neutron Multimonochromator-Bipolarizer (NMB). It consists of a multimultilayer structure made of 12 periodic multilayer Fe/Co magnetic nanostructures whose period increases with distance from the substrate. Results are presented of calculations of the reflection coefficients from the NMB. We propose a new scheme of the total neutron polarization analysis for the time-of-flight method in the reflectometry. In this scheme, double NMB is used as a polarizer and there is no spin-flipper before the sample. NMB can be used in polarized neutron reflectometry, in SESANS, and for research of low-angle and inelastic scattering of polarized neutrons.
AB - In this paper, we present a new neutron-optical element, Neutron Multimonochromator-Bipolarizer (NMB). It consists of a multimultilayer structure made of 12 periodic multilayer Fe/Co magnetic nanostructures whose period increases with distance from the substrate. Results are presented of calculations of the reflection coefficients from the NMB. We propose a new scheme of the total neutron polarization analysis for the time-of-flight method in the reflectometry. In this scheme, double NMB is used as a polarizer and there is no spin-flipper before the sample. NMB can be used in polarized neutron reflectometry, in SESANS, and for research of low-angle and inelastic scattering of polarized neutrons.
UR - http://www.scopus.com/inward/record.url?scp=85040728335&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/862/1/012016
DO - 10.1088/1742-6596/862/1/012016
M3 - Conference article
AN - SCOPUS:85040728335
VL - 862
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
SN - 1742-6588
IS - 1
M1 - 012016
T2 - 11th International Conference on Polarised Neutrons for Condensed Matter Investigations, PNCMI 2016
Y2 - 4 July 2016 through 7 July 2016
ER -
ID: 86503519