Standard

Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency. / Anderlini, L.; Anelli, M.; Archilli, F.; Auriemma, G.; Baldini, W.; Bencivenni, G.; Bizzeti, A.; Bocci, V.; Bondar, N.; Bonivento, W.; Bochin, B.; Bozzi, C.; Brundu, D.; Cadeddu, S.; Campana, P.; Carboni, G.; Cardini, A.; Carletti, M.; Casu, L.; Chubykin, A.; Ciambrone, P.; Dané, E.; De Simone, P.; Falabella, A.; Felici, G.; Fiore, M.; Fontana, M.; Fresch, P.; Furfaro, E.; Graziani, G.; Kashchuk, A.; Kotriakhova, S.; Lai, A.; Lanfranchi, G.; Loi, A.; Maev, O.; Manca, G.; Martellotti, G.; Neustroev, P.; Oldeman, R.G.C.; Palutan, M.; Passaleva, G.; Penso, G.; Pinci, D.; Polycarpo, E.; Saitta, B.; Santacesaria, R.; Santimaria, M.; Santovetti, E.; Saputi, A.; Sarti, A.; Satriano, C.; Satta, A.; Schmidt, B.; Schneider, T.; Sciascia, B.; Sciubba, A.; Siddi, B.G.; Tellarini, G.; Vacca, C.; Vazquez-Gomez, R.; Vecchi, S.; Veltri, M.; Vorobyev, A.

в: Journal of Instrumentation, Том 11, 2016.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Anderlini, L, Anelli, M, Archilli, F, Auriemma, G, Baldini, W, Bencivenni, G, Bizzeti, A, Bocci, V, Bondar, N, Bonivento, W, Bochin, B, Bozzi, C, Brundu, D, Cadeddu, S, Campana, P, Carboni, G, Cardini, A, Carletti, M, Casu, L, Chubykin, A, Ciambrone, P, Dané, E, De Simone, P, Falabella, A, Felici, G, Fiore, M, Fontana, M, Fresch, P, Furfaro, E, Graziani, G, Kashchuk, A, Kotriakhova, S, Lai, A, Lanfranchi, G, Loi, A, Maev, O, Manca, G, Martellotti, G, Neustroev, P, Oldeman, RGC, Palutan, M, Passaleva, G, Penso, G, Pinci, D, Polycarpo, E, Saitta, B, Santacesaria, R, Santimaria, M, Santovetti, E, Saputi, A, Sarti, A, Satriano, C, Satta, A, Schmidt, B, Schneider, T, Sciascia, B, Sciubba, A, Siddi, BG, Tellarini, G, Vacca, C, Vazquez-Gomez, R, Vecchi, S, Veltri, M & Vorobyev, A 2016, 'Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency', Journal of Instrumentation, Том. 11. <http://iopscience.iop.org/article/10.1088/1748-0221/11/04/P04010/pdf>

APA

Anderlini, L., Anelli, M., Archilli, F., Auriemma, G., Baldini, W., Bencivenni, G., Bizzeti, A., Bocci, V., Bondar, N., Bonivento, W., Bochin, B., Bozzi, C., Brundu, D., Cadeddu, S., Campana, P., Carboni, G., Cardini, A., Carletti, M., Casu, L., ... Vorobyev, A. (2016). Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency. Journal of Instrumentation, 11. http://iopscience.iop.org/article/10.1088/1748-0221/11/04/P04010/pdf

Vancouver

Anderlini L, Anelli M, Archilli F, Auriemma G, Baldini W, Bencivenni G и пр. Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency. Journal of Instrumentation. 2016;11.

Author

Anderlini, L. ; Anelli, M. ; Archilli, F. ; Auriemma, G. ; Baldini, W. ; Bencivenni, G. ; Bizzeti, A. ; Bocci, V. ; Bondar, N. ; Bonivento, W. ; Bochin, B. ; Bozzi, C. ; Brundu, D. ; Cadeddu, S. ; Campana, P. ; Carboni, G. ; Cardini, A. ; Carletti, M. ; Casu, L. ; Chubykin, A. ; Ciambrone, P. ; Dané, E. ; De Simone, P. ; Falabella, A. ; Felici, G. ; Fiore, M. ; Fontana, M. ; Fresch, P. ; Furfaro, E. ; Graziani, G. ; Kashchuk, A. ; Kotriakhova, S. ; Lai, A. ; Lanfranchi, G. ; Loi, A. ; Maev, O. ; Manca, G. ; Martellotti, G. ; Neustroev, P. ; Oldeman, R.G.C. ; Palutan, M. ; Passaleva, G. ; Penso, G. ; Pinci, D. ; Polycarpo, E. ; Saitta, B. ; Santacesaria, R. ; Santimaria, M. ; Santovetti, E. ; Saputi, A. ; Sarti, A. ; Satriano, C. ; Satta, A. ; Schmidt, B. ; Schneider, T. ; Sciascia, B. ; Sciubba, A. ; Siddi, B.G. ; Tellarini, G. ; Vacca, C. ; Vazquez-Gomez, R. ; Vecchi, S. ; Veltri, M. ; Vorobyev, A. / Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency. в: Journal of Instrumentation. 2016 ; Том 11.

BibTeX

@article{ea418268dfb440c294c1f174a53eae0e,
title = "Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency",
abstract = "A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from ~ 70 ns to ~ 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.",
keywords = "Front-end electronics for detector readout, Dead-time, Gaseous detectors, Muon spectrometers, Particle tracking detectors (Gaseous detectors), Wire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc)",
author = "L. Anderlini and M. Anelli and F. Archilli and G. Auriemma and W. Baldini and G. Bencivenni and A. Bizzeti and V. Bocci and N. Bondar and W. Bonivento and B. Bochin and C. Bozzi and D. Brundu and S. Cadeddu and P. Campana and G. Carboni and A. Cardini and M. Carletti and L. Casu and A. Chubykin and P. Ciambrone and E. Dan{\'e} and {De Simone}, P. and A. Falabella and G. Felici and M. Fiore and M. Fontana and P. Fresch and E. Furfaro and G. Graziani and A. Kashchuk and S. Kotriakhova and A. Lai and G. Lanfranchi and A. Loi and O. Maev and G. Manca and G. Martellotti and P. Neustroev and R.G.C. Oldeman and M. Palutan and G. Passaleva and G. Penso and D. Pinci and E. Polycarpo and B. Saitta and R. Santacesaria and M. Santimaria and E. Santovetti and A. Saputi and A. Sarti and C. Satriano and A. Satta and B. Schmidt and T. Schneider and B. Sciascia and A. Sciubba and B.G. Siddi and G. Tellarini and C. Vacca and R. Vazquez-Gomez and S. Vecchi and M. Veltri and A. Vorobyev",
year = "2016",
language = "не определен",
volume = "11",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",

}

RIS

TY - JOUR

T1 - Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

AU - Anderlini, L.

AU - Anelli, M.

AU - Archilli, F.

AU - Auriemma, G.

AU - Baldini, W.

AU - Bencivenni, G.

AU - Bizzeti, A.

AU - Bocci, V.

AU - Bondar, N.

AU - Bonivento, W.

AU - Bochin, B.

AU - Bozzi, C.

AU - Brundu, D.

AU - Cadeddu, S.

AU - Campana, P.

AU - Carboni, G.

AU - Cardini, A.

AU - Carletti, M.

AU - Casu, L.

AU - Chubykin, A.

AU - Ciambrone, P.

AU - Dané, E.

AU - De Simone, P.

AU - Falabella, A.

AU - Felici, G.

AU - Fiore, M.

AU - Fontana, M.

AU - Fresch, P.

AU - Furfaro, E.

AU - Graziani, G.

AU - Kashchuk, A.

AU - Kotriakhova, S.

AU - Lai, A.

AU - Lanfranchi, G.

AU - Loi, A.

AU - Maev, O.

AU - Manca, G.

AU - Martellotti, G.

AU - Neustroev, P.

AU - Oldeman, R.G.C.

AU - Palutan, M.

AU - Passaleva, G.

AU - Penso, G.

AU - Pinci, D.

AU - Polycarpo, E.

AU - Saitta, B.

AU - Santacesaria, R.

AU - Santimaria, M.

AU - Santovetti, E.

AU - Saputi, A.

AU - Sarti, A.

AU - Satriano, C.

AU - Satta, A.

AU - Schmidt, B.

AU - Schneider, T.

AU - Sciascia, B.

AU - Sciubba, A.

AU - Siddi, B.G.

AU - Tellarini, G.

AU - Vacca, C.

AU - Vazquez-Gomez, R.

AU - Vecchi, S.

AU - Veltri, M.

AU - Vorobyev, A.

PY - 2016

Y1 - 2016

N2 - A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from ~ 70 ns to ~ 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.

AB - A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from ~ 70 ns to ~ 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity.

KW - Front-end electronics for detector readout

KW - Dead-time

KW - Gaseous detectors

KW - Muon spectrometers

KW - Particle tracking detectors (Gaseous detectors)

KW - Wire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc)

M3 - статья

VL - 11

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

ER -

ID: 7566878