Standard

Logical criteria for estimating gas chromatographic retention indices of organic compounds using their physicochemical properties. / Зенкевич, Игорь Георгиевич.

в: Journal of Chromatography, Том 1754, 465983, 02.08.2025.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{f2c8b6bf814a45ef902bdac830e6384c,
title = "Logical criteria for estimating gas chromatographic retention indices of organic compounds using their physicochemical properties",
abstract = "There is no unified equation that would correlate gas chromatographic retention indices of any organic compounds with their normal boiling points (at atmospheric pressure). Nevertheless, RI estimation with acceptable accuracy is possible using principal physicochemical properties, namely, boiling points, relative densities, and indices of refraction. The main feature of the algorithms proposed is the application of a logical criteria for comparing so-called indices of boiling points I(Tb), molecular weights I(M), and molar refractions I(MRD). If the comparison of these indices confirms the approximate equality of any two or all three of them (that is typical for nonpolar organic compounds), then as the best estimate of GC retention indices (RIcalc) we can accept I(Tb) values without any additional calculations. Such comparison is formally equivalent to the application of logical criteria for I(Tb), I(M), and I(MRD) values. For polar analytes, the relation I(Tb) > I(MRD) > I(M) is valid, and in these cases the inequality I(Tb) > RIcalc > I(M) appeared to be correct. Instead of large intervals between I(Tb) and I(M) for estimating RIcalc, the use of the relation RIcalc ≈ (1 – a)I(Tb) + aI(MRD) + b is proposed. The indices of molecular weights are not used for the calculations directly, but they are needed just for application of the logical criteria. The average accuracy of RI estimation by the method proposed is 9–16 index units for nonpolar compounds of any chemical nature and up to 27 for polar analytes. This high accuracy is comparable to that of the more sophisticated modern algorithms. The restriction of this approach is the impossibility of applying it to poly- and perfluoroorganic compounds.",
keywords = "В тексте публикации, Gas chromatography, Indices of boiling points, Logical criteria of comparison, Molecular weights, and molar refractions, Precalculation, physicochemical characteristics of organic compounds, Retention indices",
author = "Зенкевич, {Игорь Георгиевич}",
note = "Zenkevich I.G. // J. Chromatogr. A. 2025. V. 1754. № 465983",
year = "2025",
month = aug,
day = "2",
doi = "10.1016/j.chroma.2025.465983",
language = "English",
volume = "1754",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Logical criteria for estimating gas chromatographic retention indices of organic compounds using their physicochemical properties

AU - Зенкевич, Игорь Георгиевич

N1 - Zenkevich I.G. // J. Chromatogr. A. 2025. V. 1754. № 465983

PY - 2025/8/2

Y1 - 2025/8/2

N2 - There is no unified equation that would correlate gas chromatographic retention indices of any organic compounds with their normal boiling points (at atmospheric pressure). Nevertheless, RI estimation with acceptable accuracy is possible using principal physicochemical properties, namely, boiling points, relative densities, and indices of refraction. The main feature of the algorithms proposed is the application of a logical criteria for comparing so-called indices of boiling points I(Tb), molecular weights I(M), and molar refractions I(MRD). If the comparison of these indices confirms the approximate equality of any two or all three of them (that is typical for nonpolar organic compounds), then as the best estimate of GC retention indices (RIcalc) we can accept I(Tb) values without any additional calculations. Such comparison is formally equivalent to the application of logical criteria for I(Tb), I(M), and I(MRD) values. For polar analytes, the relation I(Tb) > I(MRD) > I(M) is valid, and in these cases the inequality I(Tb) > RIcalc > I(M) appeared to be correct. Instead of large intervals between I(Tb) and I(M) for estimating RIcalc, the use of the relation RIcalc ≈ (1 – a)I(Tb) + aI(MRD) + b is proposed. The indices of molecular weights are not used for the calculations directly, but they are needed just for application of the logical criteria. The average accuracy of RI estimation by the method proposed is 9–16 index units for nonpolar compounds of any chemical nature and up to 27 for polar analytes. This high accuracy is comparable to that of the more sophisticated modern algorithms. The restriction of this approach is the impossibility of applying it to poly- and perfluoroorganic compounds.

AB - There is no unified equation that would correlate gas chromatographic retention indices of any organic compounds with their normal boiling points (at atmospheric pressure). Nevertheless, RI estimation with acceptable accuracy is possible using principal physicochemical properties, namely, boiling points, relative densities, and indices of refraction. The main feature of the algorithms proposed is the application of a logical criteria for comparing so-called indices of boiling points I(Tb), molecular weights I(M), and molar refractions I(MRD). If the comparison of these indices confirms the approximate equality of any two or all three of them (that is typical for nonpolar organic compounds), then as the best estimate of GC retention indices (RIcalc) we can accept I(Tb) values without any additional calculations. Such comparison is formally equivalent to the application of logical criteria for I(Tb), I(M), and I(MRD) values. For polar analytes, the relation I(Tb) > I(MRD) > I(M) is valid, and in these cases the inequality I(Tb) > RIcalc > I(M) appeared to be correct. Instead of large intervals between I(Tb) and I(M) for estimating RIcalc, the use of the relation RIcalc ≈ (1 – a)I(Tb) + aI(MRD) + b is proposed. The indices of molecular weights are not used for the calculations directly, but they are needed just for application of the logical criteria. The average accuracy of RI estimation by the method proposed is 9–16 index units for nonpolar compounds of any chemical nature and up to 27 for polar analytes. This high accuracy is comparable to that of the more sophisticated modern algorithms. The restriction of this approach is the impossibility of applying it to poly- and perfluoroorganic compounds.

KW - В тексте публикации

KW - Gas chromatography

KW - Indices of boiling points

KW - Logical criteria of comparison

KW - Molecular weights, and molar refractions

KW - Precalculation, physicochemical characteristics of organic compounds

KW - Retention indices

UR - https://www.mendeley.com/catalogue/7b19df80-3129-3800-92d7-4e6d4d60aeb0/

U2 - 10.1016/j.chroma.2025.465983

DO - 10.1016/j.chroma.2025.465983

M3 - Article

VL - 1754

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

M1 - 465983

ER -

ID: 136011908