The terms hold-in, pull-in (capture), and lock-in ranges are widely used by engineers for the concepts of frequency deviation ranges within which PLL-based circuits can achieve lock under various additional conditions. Usually only non-strict definitions are given for these concepts in engineering literature. After many years of their usage, F. Gardner in the 2nd edition of his well-known work, Phaselock Techniques, wrote "There is no natural way to define exactly any unique lock-in frequency" and "despite its vague reality, lock-in range is a useful concept." Recently these observations have led to the following advice given in a handbook on synchronization and communications: "We recommend that you check these definitions carefully before using them." In this survey an attempt is made to discuss and fill some of the gaps identified between mathematical control theory, the theory of dynamical systems and the engineering practice of phase-locked loops. It is shown that, from a mathematical point of view, in some cases the hold-in and pull-in "ranges" may not be the intervals of values but a union of intervals and thus their widely used definitions require clarification. Rigorous mathematical definitions for the hold-in, pull-in, and lock-in ranges are given. An effective solution for the problem on the unique definition of the lock-in frequency, posed by Gardner, is suggested.

Язык оригиналаанглийский
Номер статьи7277189
Страницы (с-по)2454-2464
Число страниц11
ЖурналIEEE Transactions on Circuits and Systems I: Regular Papers
Том62
Номер выпуска10
DOI
СостояниеОпубликовано - 1 окт 2015

    Предметные области Scopus

  • Электротехника и электроника

ID: 4005596