Standard

Graphene-based biosensors. / Davydov, V. Yu; Novikov, S. N.; Litvin, D. P.; Makarov, Yu N.; Klimovich, V. B.; Samoilovich, M. P.

в: Technical Physics Letters, Том 42, № 7, 01.07.2016, стр. 729-732.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Davydov, VY, Novikov, SN, Litvin, DP, Makarov, YN, Klimovich, VB & Samoilovich, MP 2016, 'Graphene-based biosensors', Technical Physics Letters, Том. 42, № 7, стр. 729-732. https://doi.org/10.1134/S1063785016070233

APA

Davydov, V. Y., Novikov, S. N., Litvin, D. P., Makarov, Y. N., Klimovich, V. B., & Samoilovich, M. P. (2016). Graphene-based biosensors. Technical Physics Letters, 42(7), 729-732. https://doi.org/10.1134/S1063785016070233

Vancouver

Davydov VY, Novikov SN, Litvin DP, Makarov YN, Klimovich VB, Samoilovich MP. Graphene-based biosensors. Technical Physics Letters. 2016 Июль 1;42(7):729-732. https://doi.org/10.1134/S1063785016070233

Author

Davydov, V. Yu ; Novikov, S. N. ; Litvin, D. P. ; Makarov, Yu N. ; Klimovich, V. B. ; Samoilovich, M. P. / Graphene-based biosensors. в: Technical Physics Letters. 2016 ; Том 42, № 7. стр. 729-732.

BibTeX

@article{94cc1a8fbf494395aaa4c206e4b65d84,
title = "Graphene-based biosensors",
abstract = "Results of developing and testing graphene-based sensors capable of detecting protein molecules are presented. The biosensor operation was checked using an immunochemical system comprising fluorescein dye and monoclonal antifluorescein antibodies. The sensor detects fluorescein concentration on a level of 1–10 ng/mL and bovine serum albumin–fluorescein conjugate on a level of 1–5 ng/mL. The proposed device has good prospects for use for early diagnostics of various diseases.",
author = "Davydov, {V. Yu} and Novikov, {S. N.} and Litvin, {D. P.} and Makarov, {Yu N.} and Klimovich, {V. B.} and Samoilovich, {M. P.}",
year = "2016",
month = jul,
day = "1",
doi = "10.1134/S1063785016070233",
language = "English",
volume = "42",
pages = "729--732",
journal = "Technical Physics Letters",
issn = "1063-7850",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "7",

}

RIS

TY - JOUR

T1 - Graphene-based biosensors

AU - Davydov, V. Yu

AU - Novikov, S. N.

AU - Litvin, D. P.

AU - Makarov, Yu N.

AU - Klimovich, V. B.

AU - Samoilovich, M. P.

PY - 2016/7/1

Y1 - 2016/7/1

N2 - Results of developing and testing graphene-based sensors capable of detecting protein molecules are presented. The biosensor operation was checked using an immunochemical system comprising fluorescein dye and monoclonal antifluorescein antibodies. The sensor detects fluorescein concentration on a level of 1–10 ng/mL and bovine serum albumin–fluorescein conjugate on a level of 1–5 ng/mL. The proposed device has good prospects for use for early diagnostics of various diseases.

AB - Results of developing and testing graphene-based sensors capable of detecting protein molecules are presented. The biosensor operation was checked using an immunochemical system comprising fluorescein dye and monoclonal antifluorescein antibodies. The sensor detects fluorescein concentration on a level of 1–10 ng/mL and bovine serum albumin–fluorescein conjugate on a level of 1–5 ng/mL. The proposed device has good prospects for use for early diagnostics of various diseases.

UR - http://www.scopus.com/inward/record.url?scp=84981745064&partnerID=8YFLogxK

U2 - 10.1134/S1063785016070233

DO - 10.1134/S1063785016070233

M3 - Article

AN - SCOPUS:84981745064

VL - 42

SP - 729

EP - 732

JO - Technical Physics Letters

JF - Technical Physics Letters

SN - 1063-7850

IS - 7

ER -

ID: 36422795