Standard

Fractures of the Humerus. / Solomin, Leonid Nikolaevich.

The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, 2012. стр. 303-337.

Результаты исследований: Публикации в книгах, отчётах, сборниках, трудах конференцийглава/разделнаучнаяРецензирование

Harvard

Solomin, LN 2012, Fractures of the Humerus. в The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, стр. 303-337. https://doi.org/10.1007/978-88-470-2619-3_10

APA

Solomin, L. N. (2012). Fractures of the Humerus. в The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices (стр. 303-337). Springer Nature. https://doi.org/10.1007/978-88-470-2619-3_10

Vancouver

Solomin LN. Fractures of the Humerus. в The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature. 2012. стр. 303-337 https://doi.org/10.1007/978-88-470-2619-3_10

Author

Solomin, Leonid Nikolaevich. / Fractures of the Humerus. The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices. Springer Nature, 2012. стр. 303-337

BibTeX

@inbook{979400d30fb346698ced486c42a80a43,
title = "Fractures of the Humerus",
abstract = "In external fixation of the humerus according to the Ilizarov method wires of diameter 1.5 mm are used. The basic wires used in CEF are 1.8–2 mm in diameter, and the wires used for reduction are 1.5 mm in diameter. Half-pins of diameter 5 mm are inserted into the diaphyseal part of the humerus and 4-mm half-pins or console wires are inserted into the epicondyle. For patients with bone diameters of 28–30 mm it is permissible to use 6-mm threaded half-pins throughout the first three levels (0, I, II). The set for fixation must also include 2-mmconsolewires with a stop at the positions allowing various lengths of the wire to be inserted into the bone (5, 10, 15 or 20 mm) (Figs. 10.1, 10.2, 10.3, 10.4, 10.5, 10.6, 10.7, 10.8, 10.9, 10.10, 10.11, 10.12, 10.13, 10.14, 10.15, 10.16, 10.17, and 10.18). ",
author = "Solomin, {Leonid Nikolaevich}",
year = "2012",
month = jan,
day = "1",
doi = "10.1007/978-88-470-2619-3_10",
language = "English",
isbn = "9788847026186",
pages = "303--337",
booktitle = "The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices",
publisher = "Springer Nature",
address = "Germany",

}

RIS

TY - CHAP

T1 - Fractures of the Humerus

AU - Solomin, Leonid Nikolaevich

PY - 2012/1/1

Y1 - 2012/1/1

N2 - In external fixation of the humerus according to the Ilizarov method wires of diameter 1.5 mm are used. The basic wires used in CEF are 1.8–2 mm in diameter, and the wires used for reduction are 1.5 mm in diameter. Half-pins of diameter 5 mm are inserted into the diaphyseal part of the humerus and 4-mm half-pins or console wires are inserted into the epicondyle. For patients with bone diameters of 28–30 mm it is permissible to use 6-mm threaded half-pins throughout the first three levels (0, I, II). The set for fixation must also include 2-mmconsolewires with a stop at the positions allowing various lengths of the wire to be inserted into the bone (5, 10, 15 or 20 mm) (Figs. 10.1, 10.2, 10.3, 10.4, 10.5, 10.6, 10.7, 10.8, 10.9, 10.10, 10.11, 10.12, 10.13, 10.14, 10.15, 10.16, 10.17, and 10.18).

AB - In external fixation of the humerus according to the Ilizarov method wires of diameter 1.5 mm are used. The basic wires used in CEF are 1.8–2 mm in diameter, and the wires used for reduction are 1.5 mm in diameter. Half-pins of diameter 5 mm are inserted into the diaphyseal part of the humerus and 4-mm half-pins or console wires are inserted into the epicondyle. For patients with bone diameters of 28–30 mm it is permissible to use 6-mm threaded half-pins throughout the first three levels (0, I, II). The set for fixation must also include 2-mmconsolewires with a stop at the positions allowing various lengths of the wire to be inserted into the bone (5, 10, 15 or 20 mm) (Figs. 10.1, 10.2, 10.3, 10.4, 10.5, 10.6, 10.7, 10.8, 10.9, 10.10, 10.11, 10.12, 10.13, 10.14, 10.15, 10.16, 10.17, and 10.18).

UR - http://www.scopus.com/inward/record.url?scp=84957025701&partnerID=8YFLogxK

U2 - 10.1007/978-88-470-2619-3_10

DO - 10.1007/978-88-470-2619-3_10

M3 - Chapter

AN - SCOPUS:84957025701

SN - 9788847026186

SP - 303

EP - 337

BT - The Basic Principles of External Skeletal Fixation Using the Ilizarov and Other Devices

PB - Springer Nature

ER -

ID: 49735478