Результаты исследований: Научные публикации в периодических изданиях › статья в журнале по материалам конференции › Рецензирование
Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors. / Legin, A. V.; Rudnitskaya, A. M.; Vlasov, Yu G.; Di Natale, C.; D'Amico, A.
в: Sensors and Actuators, B: Chemical, Том 58, № 1-3, 21.09.1999, стр. 464-468.Результаты исследований: Научные публикации в периодических изданиях › статья в журнале по материалам конференции › Рецензирование
}
TY - JOUR
T1 - Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors
AU - Legin, A. V.
AU - Rudnitskaya, A. M.
AU - Vlasov, Yu G.
AU - Di Natale, C.
AU - D'Amico, A.
PY - 1999/9/21
Y1 - 1999/9/21
N2 - A comparison of the features of the electronic tongue; comprising an array of non-specific chemical sensors and pattern recognition methods, with analytical characteristics of the discrete conventional ion-selective sensors (electrodes) has been performed. A method has been suggested that allows observing the detection limit and the selectivity of a sensor array at least three to five times better than that for a single sensor. The electronic tongue also exhibits a number of completely new features, such as the possibility to determine some unusual species in solutions, e.g. organic substances, and the capability to make measurements without the standard reference electrode.
AB - A comparison of the features of the electronic tongue; comprising an array of non-specific chemical sensors and pattern recognition methods, with analytical characteristics of the discrete conventional ion-selective sensors (electrodes) has been performed. A method has been suggested that allows observing the detection limit and the selectivity of a sensor array at least three to five times better than that for a single sensor. The electronic tongue also exhibits a number of completely new features, such as the possibility to determine some unusual species in solutions, e.g. organic substances, and the capability to make measurements without the standard reference electrode.
UR - http://www.scopus.com/inward/record.url?scp=0343192272&partnerID=8YFLogxK
U2 - 10.1016/S0925-4005(99)00127-6
DO - 10.1016/S0925-4005(99)00127-6
M3 - Conference article
AN - SCOPUS:0343192272
VL - 58
SP - 464
EP - 468
JO - Sensors and Actuators, B: Chemical
JF - Sensors and Actuators, B: Chemical
SN - 0925-4005
IS - 1-3
T2 - Proceedings of the 1998 Eurosensors XII
Y2 - 13 September 1998 through 16 September 1998
ER -
ID: 30517368