Standard

Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors. / Legin, A. V.; Rudnitskaya, A. M.; Vlasov, Yu G.; Di Natale, C.; D'Amico, A.

в: Sensors and Actuators, B: Chemical, Том 58, № 1-3, 21.09.1999, стр. 464-468.

Результаты исследований: Научные публикации в периодических изданияхстатья в журнале по материалам конференцииРецензирование

Harvard

Legin, AV, Rudnitskaya, AM, Vlasov, YG, Di Natale, C & D'Amico, A 1999, 'Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors', Sensors and Actuators, B: Chemical, Том. 58, № 1-3, стр. 464-468. https://doi.org/10.1016/S0925-4005(99)00127-6

APA

Legin, A. V., Rudnitskaya, A. M., Vlasov, Y. G., Di Natale, C., & D'Amico, A. (1999). Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors. Sensors and Actuators, B: Chemical, 58(1-3), 464-468. https://doi.org/10.1016/S0925-4005(99)00127-6

Vancouver

Legin AV, Rudnitskaya AM, Vlasov YG, Di Natale C, D'Amico A. Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors. Sensors and Actuators, B: Chemical. 1999 Сент. 21;58(1-3):464-468. https://doi.org/10.1016/S0925-4005(99)00127-6

Author

Legin, A. V. ; Rudnitskaya, A. M. ; Vlasov, Yu G. ; Di Natale, C. ; D'Amico, A. / Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors. в: Sensors and Actuators, B: Chemical. 1999 ; Том 58, № 1-3. стр. 464-468.

BibTeX

@article{ea22410be8814042960e2eb636e0fef3,
title = "Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors",
abstract = "A comparison of the features of the electronic tongue; comprising an array of non-specific chemical sensors and pattern recognition methods, with analytical characteristics of the discrete conventional ion-selective sensors (electrodes) has been performed. A method has been suggested that allows observing the detection limit and the selectivity of a sensor array at least three to five times better than that for a single sensor. The electronic tongue also exhibits a number of completely new features, such as the possibility to determine some unusual species in solutions, e.g. organic substances, and the capability to make measurements without the standard reference electrode.",
author = "Legin, {A. V.} and Rudnitskaya, {A. M.} and Vlasov, {Yu G.} and {Di Natale}, C. and A. D'Amico",
year = "1999",
month = sep,
day = "21",
doi = "10.1016/S0925-4005(99)00127-6",
language = "English",
volume = "58",
pages = "464--468",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "1-3",
note = "Proceedings of the 1998 Eurosensors XII ; Conference date: 13-09-1998 Through 16-09-1998",

}

RIS

TY - JOUR

T1 - Features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors

AU - Legin, A. V.

AU - Rudnitskaya, A. M.

AU - Vlasov, Yu G.

AU - Di Natale, C.

AU - D'Amico, A.

PY - 1999/9/21

Y1 - 1999/9/21

N2 - A comparison of the features of the electronic tongue; comprising an array of non-specific chemical sensors and pattern recognition methods, with analytical characteristics of the discrete conventional ion-selective sensors (electrodes) has been performed. A method has been suggested that allows observing the detection limit and the selectivity of a sensor array at least three to five times better than that for a single sensor. The electronic tongue also exhibits a number of completely new features, such as the possibility to determine some unusual species in solutions, e.g. organic substances, and the capability to make measurements without the standard reference electrode.

AB - A comparison of the features of the electronic tongue; comprising an array of non-specific chemical sensors and pattern recognition methods, with analytical characteristics of the discrete conventional ion-selective sensors (electrodes) has been performed. A method has been suggested that allows observing the detection limit and the selectivity of a sensor array at least three to five times better than that for a single sensor. The electronic tongue also exhibits a number of completely new features, such as the possibility to determine some unusual species in solutions, e.g. organic substances, and the capability to make measurements without the standard reference electrode.

UR - http://www.scopus.com/inward/record.url?scp=0343192272&partnerID=8YFLogxK

U2 - 10.1016/S0925-4005(99)00127-6

DO - 10.1016/S0925-4005(99)00127-6

M3 - Conference article

AN - SCOPUS:0343192272

VL - 58

SP - 464

EP - 468

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 1-3

T2 - Proceedings of the 1998 Eurosensors XII

Y2 - 13 September 1998 through 16 September 1998

ER -

ID: 30517368