Standard

Features and Advantages of the Recurrent Approximation of Retention Times in Reversed-Phase High-Performance Liquid Chromatography. / Зенкевич, Игорь Георгиевич; Деруиш, Абденнур.

в: Separations, Том 11, № 3, 69, 24.02.2024.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{f43707c279764566a1607c8214d8ef17,
title = "Features and Advantages of the Recurrent Approximation of Retention Times in Reversed-Phase High-Performance Liquid Chromatography",
abstract = "Background: Recurrent approximation of retention parameters in reversed-phase HPLC is effective for revealing anomalies that are otherwise difficult to detect, namely, the reversible hydration of analytes. This was demonstrated previously for restricted sets of analytes with acetonitrile–water eluents. Expanding the number of analytes and eluents seems to be a topical problem. Two kinds of derivatives of aromatic carbonyl compounds were characterized: unsubstituted hydrazones and oximes. Methods: If analyte demonstrates no anomalies in dependences of retention times vs. concentration of organic modifier, the recurrent approximations of these dependences are linear. To explain the features of recurrent approximations, the numerical experiments were proposed and considered. The artificial shifting of one, two, or more points allows for the modeling the different kinds of deviations of approximations from linearity. Results: It was shown that hydrazones are the class of analytes having no anomalies of retention parameters. On the contrary, several anomalies were detected for oximes. Downward deviations of points in the plots of recurrent approximations of retention times are the signs of reversible hydration. This effect for methanol–water eluents was detected for the first time. Some of oximes underwent hydrolysis. Conclusions: Recurrent approximation of retention times allows detecting chemical transformations of analytes during RP HPLC analysis.",
keywords = "В тексте публикации, In the text of the article",
author = "Зенкевич, {Игорь Георгиевич} and Абденнур Деруиш",
note = "Zenkevich I.G., Derouiche A. // Separations. 2024. V. 11. No. 69. P. 1-19.",
year = "2024",
month = feb,
day = "24",
doi = "10.3390/separations11030069",
language = "English",
volume = "11",
journal = "Separations",
issn = "2297-8739",
publisher = "MDPI AG",
number = "3",

}

RIS

TY - JOUR

T1 - Features and Advantages of the Recurrent Approximation of Retention Times in Reversed-Phase High-Performance Liquid Chromatography

AU - Зенкевич, Игорь Георгиевич

AU - Деруиш, Абденнур

N1 - Zenkevich I.G., Derouiche A. // Separations. 2024. V. 11. No. 69. P. 1-19.

PY - 2024/2/24

Y1 - 2024/2/24

N2 - Background: Recurrent approximation of retention parameters in reversed-phase HPLC is effective for revealing anomalies that are otherwise difficult to detect, namely, the reversible hydration of analytes. This was demonstrated previously for restricted sets of analytes with acetonitrile–water eluents. Expanding the number of analytes and eluents seems to be a topical problem. Two kinds of derivatives of aromatic carbonyl compounds were characterized: unsubstituted hydrazones and oximes. Methods: If analyte demonstrates no anomalies in dependences of retention times vs. concentration of organic modifier, the recurrent approximations of these dependences are linear. To explain the features of recurrent approximations, the numerical experiments were proposed and considered. The artificial shifting of one, two, or more points allows for the modeling the different kinds of deviations of approximations from linearity. Results: It was shown that hydrazones are the class of analytes having no anomalies of retention parameters. On the contrary, several anomalies were detected for oximes. Downward deviations of points in the plots of recurrent approximations of retention times are the signs of reversible hydration. This effect for methanol–water eluents was detected for the first time. Some of oximes underwent hydrolysis. Conclusions: Recurrent approximation of retention times allows detecting chemical transformations of analytes during RP HPLC analysis.

AB - Background: Recurrent approximation of retention parameters in reversed-phase HPLC is effective for revealing anomalies that are otherwise difficult to detect, namely, the reversible hydration of analytes. This was demonstrated previously for restricted sets of analytes with acetonitrile–water eluents. Expanding the number of analytes and eluents seems to be a topical problem. Two kinds of derivatives of aromatic carbonyl compounds were characterized: unsubstituted hydrazones and oximes. Methods: If analyte demonstrates no anomalies in dependences of retention times vs. concentration of organic modifier, the recurrent approximations of these dependences are linear. To explain the features of recurrent approximations, the numerical experiments were proposed and considered. The artificial shifting of one, two, or more points allows for the modeling the different kinds of deviations of approximations from linearity. Results: It was shown that hydrazones are the class of analytes having no anomalies of retention parameters. On the contrary, several anomalies were detected for oximes. Downward deviations of points in the plots of recurrent approximations of retention times are the signs of reversible hydration. This effect for methanol–water eluents was detected for the first time. Some of oximes underwent hydrolysis. Conclusions: Recurrent approximation of retention times allows detecting chemical transformations of analytes during RP HPLC analysis.

KW - В тексте публикации

KW - In the text of the article

UR - https://www.mendeley.com/catalogue/0b4bfde7-9480-315c-9226-8b0a8233f0bf/

U2 - 10.3390/separations11030069

DO - 10.3390/separations11030069

M3 - Article

VL - 11

JO - Separations

JF - Separations

SN - 2297-8739

IS - 3

M1 - 69

ER -

ID: 118540244