Standard

Fast beam–beam collisions monitor for experiments at NICA. / Baldin, A. A.; Feofilov, G. A.; Har'yuzov, P.; Valiev, F. F.

в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 958, 162154, 01.01.2019.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Baldin, AA, Feofilov, GA, Har'yuzov, P & Valiev, FF 2019, 'Fast beam–beam collisions monitor for experiments at NICA', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 958, 162154. https://doi.org/10.1016/j.nima.2019.04.108

APA

Baldin, A. A., Feofilov, G. A., Har'yuzov, P., & Valiev, F. F. (Принято в печать). Fast beam–beam collisions monitor for experiments at NICA. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 958, [162154]. https://doi.org/10.1016/j.nima.2019.04.108

Vancouver

Baldin AA, Feofilov GA, Har'yuzov P, Valiev FF. Fast beam–beam collisions monitor for experiments at NICA. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 Янв. 1;958. 162154. https://doi.org/10.1016/j.nima.2019.04.108

Author

Baldin, A. A. ; Feofilov, G. A. ; Har'yuzov, P. ; Valiev, F. F. / Fast beam–beam collisions monitor for experiments at NICA. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2019 ; Том 958.

BibTeX

@article{097ee77382134fe6b0c7cee9b56e7159,
title = "Fast beam–beam collisions monitor for experiments at NICA",
abstract = "Two compact detector systems are proposed to meet the challenges of the fast beam–beam collisions monitoring, event selection and the precise timing determination in proton–proton and nucleus–nucleus collisions at NICA. Beam Position Monitor (BPM) and Fast Beam–Beam Collision (FBBC) monitor are capable to provide the information for each bunch crossing both on the beams location and on the intensity of collisions, as well as on the azimuthal distribution of the particles in the event. The systems are using fast Micro Channel Plate detectors (MCPs). The ultra-high vacuum (UHV) compatibility and low-mass compact design of the BPM and FBBC components allow one to consider their application inside the vacuum beam line of NICA collider. The BPM is based on the effect of the residual gas ionization and provides the high accuracy, fast, bunch-by-bunch measurements of the beam location. The FBBC uses the concept of the fast isochronous timing for the multi-pad readout of short (∼1ns) MCP signals, produced by the particles in the collisions of the beams. Studies of the polarization phenomena in light- and heavy-ion interactions at NICA beams is another goal of research at NICA, and the FBBC is also considered for the local polarimetry at the SPD. In this report we present the results of model simulations and tests of the new prototypes of the fast MCP readout set-ups that are proposed for NICA.",
keywords = "Beam–beam collisions monitor, Micro Channel Plates, NICA",
author = "Baldin, {A. A.} and Feofilov, {G. A.} and P. Har'yuzov and Valiev, {F. F.}",
year = "2019",
month = jan,
day = "1",
doi = "10.1016/j.nima.2019.04.108",
language = "English",
volume = "958",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Fast beam–beam collisions monitor for experiments at NICA

AU - Baldin, A. A.

AU - Feofilov, G. A.

AU - Har'yuzov, P.

AU - Valiev, F. F.

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Two compact detector systems are proposed to meet the challenges of the fast beam–beam collisions monitoring, event selection and the precise timing determination in proton–proton and nucleus–nucleus collisions at NICA. Beam Position Monitor (BPM) and Fast Beam–Beam Collision (FBBC) monitor are capable to provide the information for each bunch crossing both on the beams location and on the intensity of collisions, as well as on the azimuthal distribution of the particles in the event. The systems are using fast Micro Channel Plate detectors (MCPs). The ultra-high vacuum (UHV) compatibility and low-mass compact design of the BPM and FBBC components allow one to consider their application inside the vacuum beam line of NICA collider. The BPM is based on the effect of the residual gas ionization and provides the high accuracy, fast, bunch-by-bunch measurements of the beam location. The FBBC uses the concept of the fast isochronous timing for the multi-pad readout of short (∼1ns) MCP signals, produced by the particles in the collisions of the beams. Studies of the polarization phenomena in light- and heavy-ion interactions at NICA beams is another goal of research at NICA, and the FBBC is also considered for the local polarimetry at the SPD. In this report we present the results of model simulations and tests of the new prototypes of the fast MCP readout set-ups that are proposed for NICA.

AB - Two compact detector systems are proposed to meet the challenges of the fast beam–beam collisions monitoring, event selection and the precise timing determination in proton–proton and nucleus–nucleus collisions at NICA. Beam Position Monitor (BPM) and Fast Beam–Beam Collision (FBBC) monitor are capable to provide the information for each bunch crossing both on the beams location and on the intensity of collisions, as well as on the azimuthal distribution of the particles in the event. The systems are using fast Micro Channel Plate detectors (MCPs). The ultra-high vacuum (UHV) compatibility and low-mass compact design of the BPM and FBBC components allow one to consider their application inside the vacuum beam line of NICA collider. The BPM is based on the effect of the residual gas ionization and provides the high accuracy, fast, bunch-by-bunch measurements of the beam location. The FBBC uses the concept of the fast isochronous timing for the multi-pad readout of short (∼1ns) MCP signals, produced by the particles in the collisions of the beams. Studies of the polarization phenomena in light- and heavy-ion interactions at NICA beams is another goal of research at NICA, and the FBBC is also considered for the local polarimetry at the SPD. In this report we present the results of model simulations and tests of the new prototypes of the fast MCP readout set-ups that are proposed for NICA.

KW - Beam–beam collisions monitor

KW - Micro Channel Plates

KW - NICA

UR - http://www.scopus.com/inward/record.url?scp=85066409935&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2019.04.108

DO - 10.1016/j.nima.2019.04.108

M3 - Article

AN - SCOPUS:85066409935

VL - 958

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

M1 - 162154

ER -

ID: 51040063