Standard

Experimental study of the focusing of submicrosecond pressure pulses in liquids. / Sud'enkov, Yu V.; Ivanov, É V.

в: Technical Physics, Том 43, № 6, 01.12.1998, стр. 714-719.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

Sud'enkov, Yu V. ; Ivanov, É V. / Experimental study of the focusing of submicrosecond pressure pulses in liquids. в: Technical Physics. 1998 ; Том 43, № 6. стр. 714-719.

BibTeX

@article{f988ec2ef07a460c8f6c553a9a1faace,
title = "Experimental study of the focusing of submicrosecond pressure pulses in liquids",
abstract = "Experimental data are presented from a study of the focusing of single, submicrosecond pressure pulses in water. The effects of the initial amplitude distribution, the initial pressure level, and the geometric parameters of the opto-acoustic concentrator are studied. It is found that the focusing efficiency can be substantially enhanced by going from a bell-shaped distribution of the initial amplitude to an annular distribution.",
author = "Sud'enkov, {Yu V.} and Ivanov, {{\'E} V.}",
year = "1998",
month = dec,
day = "1",
doi = "10.1134/1.1259059",
language = "English",
volume = "43",
pages = "714--719",
journal = "Technical Physics",
issn = "1063-7842",
publisher = "Pleiades Publishing",
number = "6",

}

RIS

TY - JOUR

T1 - Experimental study of the focusing of submicrosecond pressure pulses in liquids

AU - Sud'enkov, Yu V.

AU - Ivanov, É V.

PY - 1998/12/1

Y1 - 1998/12/1

N2 - Experimental data are presented from a study of the focusing of single, submicrosecond pressure pulses in water. The effects of the initial amplitude distribution, the initial pressure level, and the geometric parameters of the opto-acoustic concentrator are studied. It is found that the focusing efficiency can be substantially enhanced by going from a bell-shaped distribution of the initial amplitude to an annular distribution.

AB - Experimental data are presented from a study of the focusing of single, submicrosecond pressure pulses in water. The effects of the initial amplitude distribution, the initial pressure level, and the geometric parameters of the opto-acoustic concentrator are studied. It is found that the focusing efficiency can be substantially enhanced by going from a bell-shaped distribution of the initial amplitude to an annular distribution.

UR - http://www.scopus.com/inward/record.url?scp=0032365909&partnerID=8YFLogxK

U2 - 10.1134/1.1259059

DO - 10.1134/1.1259059

M3 - Article

AN - SCOPUS:0032365909

VL - 43

SP - 714

EP - 719

JO - Technical Physics

JF - Technical Physics

SN - 1063-7842

IS - 6

ER -