Standard

Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers. / Trunov, D. N.; Marin, V. N.; Sadykov, R. A.; Altynbaev, E. V.; Glushkova, T. I.

в: Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, Том 18, № 4, 01.08.2024, стр. 881–886.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Trunov, DN, Marin, VN, Sadykov, RA, Altynbaev, EV & Glushkova, TI 2024, 'Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers', Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, Том. 18, № 4, стр. 881–886. https://doi.org/10.1134/s1027451024700599

APA

Trunov, D. N., Marin, V. N., Sadykov, R. A., Altynbaev, E. V., & Glushkova, T. I. (2024). Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers. Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques, 18(4), 881–886. https://doi.org/10.1134/s1027451024700599

Vancouver

Trunov DN, Marin VN, Sadykov RA, Altynbaev EV, Glushkova TI. Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers. Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques. 2024 Авг. 1;18(4):881–886. https://doi.org/10.1134/s1027451024700599

Author

Trunov, D. N. ; Marin, V. N. ; Sadykov, R. A. ; Altynbaev, E. V. ; Glushkova, T. I. / Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers. в: Journal of Surface Investigation X-Ray, Synchrotron and Neutron Techniques. 2024 ; Том 18, № 4. стр. 881–886.

BibTeX

@article{e1e32b96d887406eaa18673429a07ea3,
title = "Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers",
abstract = "Abstract: A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.",
keywords = "Geiger avalanche photodiodes, detectors, light guide, multilayer detector, neutrons, organic light guide, scintillation detector, scintillator, silicon photomultipliers, wavelngth shifting fibers",
author = "Trunov, {D. N.} and Marin, {V. N.} and Sadykov, {R. A.} and Altynbaev, {E. V.} and Glushkova, {T. I.}",
year = "2024",
month = aug,
day = "1",
doi = "10.1134/s1027451024700599",
language = "English",
volume = "18",
pages = "881–886",
journal = "ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ",
issn = "1027-4510",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "4",

}

RIS

TY - JOUR

T1 - Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers

AU - Trunov, D. N.

AU - Marin, V. N.

AU - Sadykov, R. A.

AU - Altynbaev, E. V.

AU - Glushkova, T. I.

PY - 2024/8/1

Y1 - 2024/8/1

N2 - Abstract: A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.

AB - Abstract: A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.

KW - Geiger avalanche photodiodes

KW - detectors

KW - light guide

KW - multilayer detector

KW - neutrons

KW - organic light guide

KW - scintillation detector

KW - scintillator

KW - silicon photomultipliers

KW - wavelngth shifting fibers

UR - https://www.mendeley.com/catalogue/0aed89b2-1991-3df0-8d7e-28198f22812d/

U2 - 10.1134/s1027451024700599

DO - 10.1134/s1027451024700599

M3 - Article

VL - 18

SP - 881

EP - 886

JO - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

JF - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

SN - 1027-4510

IS - 4

ER -