Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
Determination of Ethanol in Soft Drinks by Gas Chromatography Using Headspace Single-Drop Microextraction. / Родинков, Олег Васильевич; Давлетбаева, Карина Насимовна.
в: Journal of Analytical Chemistry, Том 80, № 8, 01.08.2025, стр. 1354-1359.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - Determination of Ethanol in Soft Drinks by Gas Chromatography Using Headspace Single-Drop Microextraction
AU - Родинков, Олег Васильевич
AU - Давлетбаева, Карина Насимовна
PY - 2025/8/1
Y1 - 2025/8/1
N2 - Abstract: A simple and a rapid procedure for the gas-chromatographic determination of ethanol in soft drinks is proposed (kvass, grape juice, non-alcoholic beer) based on the headspace microextraction of an analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of a needle of a standard microsyringe for gas chromatography. The limit of detection for ethanol is (3–6) × 10–5 vol %, the time of a replicate determination, including headspace extraction, does not exceed 5 min. 2-Propanol, not detected in the beverages, is used as an internal standard. The accuracy of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7% at the ethanol concentration in the sample 10–2 vol %.
AB - Abstract: A simple and a rapid procedure for the gas-chromatographic determination of ethanol in soft drinks is proposed (kvass, grape juice, non-alcoholic beer) based on the headspace microextraction of an analyte into a drop (1 μL) of distilled water located above the surface of the analyzed liquid on the tip of a needle of a standard microsyringe for gas chromatography. The limit of detection for ethanol is (3–6) × 10–5 vol %, the time of a replicate determination, including headspace extraction, does not exceed 5 min. 2-Propanol, not detected in the beverages, is used as an internal standard. The accuracy of the procedure is confirmed by the added–found method, the relative standard deviation does not exceed 7% at the ethanol concentration in the sample 10–2 vol %.
KW - determination
KW - ethanol
KW - gas chromatography
KW - headspace drop microextraction
KW - non-alcoholic beverages
UR - https://www.mendeley.com/catalogue/49581de0-b33e-3b8d-a040-caa88374fe9a/
U2 - 10.1134/s1061934825700625
DO - 10.1134/s1061934825700625
M3 - Article
VL - 80
SP - 1354
EP - 1359
JO - Journal of Analytical Chemistry
JF - Journal of Analytical Chemistry
SN - 1061-9348
IS - 8
ER -
ID: 142803107