Standard

Deep eutectic solvents-based headspace single-drop microextraction for the chromatographic determination of phenols and aliphatic alcohols in atmospheric air. / Rodinkov, Oleg; Znamenskaya, Ekaterina; Spivakovsky, Valeriy; Shilov, Roman; Shishov, Andrey.

в: Microchemical Journal, Том 182, 107854, 01.11.2022.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{ab0312ebe06145b9a626b88d1d2e45fd,
title = "Deep eutectic solvents-based headspace single-drop microextraction for the chromatographic determination of phenols and aliphatic alcohols in atmospheric air",
abstract = "In this work, the possibility for gas chromatography determination of volatile organic compounds in atmospheric air with preliminary microextraction into single drop of a deep eutectic solvent is presented for the first time. Highly toxic compounds (phenol, o-cresol) and aliphatic alcohols (methanol, n-butanol, n-pentanol) were selected as analytes for which low MPCs in the atmospheric air were established. A eutectic mixture of natural, environmentally friendly substances menthol and thymol was used as an extractant. The resulting eutectic solvent forms a stable drop that allows the rapid extraction of analytes from the gas phase. 30 min of sampling is enough to achieve sensitivity at the level of maximum permissible concentrations of these analytes in atmospheric air. At the same time, the volatility of the components of the eutectic compound themselves made it possible to introduce this solvent directly into the gas chromatograph without dilution. The developed procedure was used to analyze real air samples and standard gas mixtures. The limits of detection for analytes were in the range 0.001–0.01 mg L−1. The RSD for all analytes was <5 %. This sample preparation method can be easily and efficiently combined with subsequent chromatographic detection.",
keywords = "Chromatographic determination, Deep eutectic solvent, Single-drop microextraction, Volatile organic compounds, air",
author = "Oleg Rodinkov and Ekaterina Znamenskaya and Valeriy Spivakovsky and Roman Shilov and Andrey Shishov",
note = "Publisher Copyright: {\textcopyright} 2022 Elsevier B.V.",
year = "2022",
month = nov,
day = "1",
doi = "10.1016/j.microc.2022.107854",
language = "English",
volume = "182",
journal = "Microchemical Journal",
issn = "0026-265X",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Deep eutectic solvents-based headspace single-drop microextraction for the chromatographic determination of phenols and aliphatic alcohols in atmospheric air

AU - Rodinkov, Oleg

AU - Znamenskaya, Ekaterina

AU - Spivakovsky, Valeriy

AU - Shilov, Roman

AU - Shishov, Andrey

N1 - Publisher Copyright: © 2022 Elsevier B.V.

PY - 2022/11/1

Y1 - 2022/11/1

N2 - In this work, the possibility for gas chromatography determination of volatile organic compounds in atmospheric air with preliminary microextraction into single drop of a deep eutectic solvent is presented for the first time. Highly toxic compounds (phenol, o-cresol) and aliphatic alcohols (methanol, n-butanol, n-pentanol) were selected as analytes for which low MPCs in the atmospheric air were established. A eutectic mixture of natural, environmentally friendly substances menthol and thymol was used as an extractant. The resulting eutectic solvent forms a stable drop that allows the rapid extraction of analytes from the gas phase. 30 min of sampling is enough to achieve sensitivity at the level of maximum permissible concentrations of these analytes in atmospheric air. At the same time, the volatility of the components of the eutectic compound themselves made it possible to introduce this solvent directly into the gas chromatograph without dilution. The developed procedure was used to analyze real air samples and standard gas mixtures. The limits of detection for analytes were in the range 0.001–0.01 mg L−1. The RSD for all analytes was <5 %. This sample preparation method can be easily and efficiently combined with subsequent chromatographic detection.

AB - In this work, the possibility for gas chromatography determination of volatile organic compounds in atmospheric air with preliminary microextraction into single drop of a deep eutectic solvent is presented for the first time. Highly toxic compounds (phenol, o-cresol) and aliphatic alcohols (methanol, n-butanol, n-pentanol) were selected as analytes for which low MPCs in the atmospheric air were established. A eutectic mixture of natural, environmentally friendly substances menthol and thymol was used as an extractant. The resulting eutectic solvent forms a stable drop that allows the rapid extraction of analytes from the gas phase. 30 min of sampling is enough to achieve sensitivity at the level of maximum permissible concentrations of these analytes in atmospheric air. At the same time, the volatility of the components of the eutectic compound themselves made it possible to introduce this solvent directly into the gas chromatograph without dilution. The developed procedure was used to analyze real air samples and standard gas mixtures. The limits of detection for analytes were in the range 0.001–0.01 mg L−1. The RSD for all analytes was <5 %. This sample preparation method can be easily and efficiently combined with subsequent chromatographic detection.

KW - Chromatographic determination

KW - Deep eutectic solvent

KW - Single-drop microextraction

KW - Volatile organic compounds, air

UR - http://www.scopus.com/inward/record.url?scp=85135715565&partnerID=8YFLogxK

U2 - 10.1016/j.microc.2022.107854

DO - 10.1016/j.microc.2022.107854

M3 - Article

AN - SCOPUS:85135715565

VL - 182

JO - Microchemical Journal

JF - Microchemical Journal

SN - 0026-265X

M1 - 107854

ER -

ID: 98028815