Continuous monitoring of water quality at aeration plant with potentiometric sensor array. / Belikova, Valeria; Panchuk, Vitaly; Legin, Evgeny; Melenteva, Anastasia; Kirsanov, Dmitry; Legin, Andrey.

в: Sensors and Actuators, B: Chemical, Том 282, 01.03.2019, стр. 854-860.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

Belikova, Valeria ; Panchuk, Vitaly ; Legin, Evgeny ; Melenteva, Anastasia ; Kirsanov, Dmitry ; Legin, Andrey. / Continuous monitoring of water quality at aeration plant with potentiometric sensor array. в: Sensors and Actuators, B: Chemical. 2019 ; Том 282. стр. 854-860.

BibTeX

@article{32989c120f454221b8ac695f97b35227,
title = "Continuous monitoring of water quality at aeration plant with potentiometric sensor array",
abstract = "The potential of multisensor array in continuous on-line monitoring of processed water quality at aeration plant is explored. The responses of 23 potentiometric sensors were continuously registered every seven seconds through the 26 days of experiment in a special container having connection with outlet water line of the aeration plant. Using chemometric tools it is shown that potentiometric “electronic tongue” is capable of evaluation of two important parameters of water quality: ammonium nitrogen and nitrate nitrogen. Unlike traditional sampling-based analysis the results of multisensor are available immediately in a real-time mode. Moreover, the achieved precision is sufficient to monitor possible alarm events. The employment of topological data analysis allowed for exploration of the very large dataset (295,828 measurements) accumulated through the long period of continuous measurements with sensors and for judgment on stability of water quality.",
keywords = "Chemometrics, Multisensor systems, On-line monitoring, Water quality, ELECTRONIC TONGUE, ANALYTICAL TECHNOLOGY PAT, TOOL",
author = "Valeria Belikova and Vitaly Panchuk and Evgeny Legin and Anastasia Melenteva and Dmitry Kirsanov and Andrey Legin",
year = "2019",
month = mar,
day = "1",
doi = "10.1016/j.snb.2018.11.153",
language = "English",
volume = "282",
pages = "854--860",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Continuous monitoring of water quality at aeration plant with potentiometric sensor array

AU - Belikova, Valeria

AU - Panchuk, Vitaly

AU - Legin, Evgeny

AU - Melenteva, Anastasia

AU - Kirsanov, Dmitry

AU - Legin, Andrey

PY - 2019/3/1

Y1 - 2019/3/1

N2 - The potential of multisensor array in continuous on-line monitoring of processed water quality at aeration plant is explored. The responses of 23 potentiometric sensors were continuously registered every seven seconds through the 26 days of experiment in a special container having connection with outlet water line of the aeration plant. Using chemometric tools it is shown that potentiometric “electronic tongue” is capable of evaluation of two important parameters of water quality: ammonium nitrogen and nitrate nitrogen. Unlike traditional sampling-based analysis the results of multisensor are available immediately in a real-time mode. Moreover, the achieved precision is sufficient to monitor possible alarm events. The employment of topological data analysis allowed for exploration of the very large dataset (295,828 measurements) accumulated through the long period of continuous measurements with sensors and for judgment on stability of water quality.

AB - The potential of multisensor array in continuous on-line monitoring of processed water quality at aeration plant is explored. The responses of 23 potentiometric sensors were continuously registered every seven seconds through the 26 days of experiment in a special container having connection with outlet water line of the aeration plant. Using chemometric tools it is shown that potentiometric “electronic tongue” is capable of evaluation of two important parameters of water quality: ammonium nitrogen and nitrate nitrogen. Unlike traditional sampling-based analysis the results of multisensor are available immediately in a real-time mode. Moreover, the achieved precision is sufficient to monitor possible alarm events. The employment of topological data analysis allowed for exploration of the very large dataset (295,828 measurements) accumulated through the long period of continuous measurements with sensors and for judgment on stability of water quality.

KW - Chemometrics

KW - Multisensor systems

KW - On-line monitoring

KW - Water quality

KW - ELECTRONIC TONGUE

KW - ANALYTICAL TECHNOLOGY PAT

KW - TOOL

UR - http://www.scopus.com/inward/record.url?scp=85057436207&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2018.11.153

DO - 10.1016/j.snb.2018.11.153

M3 - Article

AN - SCOPUS:85057436207

VL - 282

SP - 854

EP - 860

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -

ID: 41461192