Standard

Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments. / Tarnavich, V. V.; Ukleev, V. A.; Chernenkov, Yu P.; Volegov, A. S.; Grigoriev, S. V.

в: Journal of Surface Investigation, Том 13, № 4, 01.07.2019, стр. 567-569.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

Tarnavich, VV, Ukleev, VA, Chernenkov, YP, Volegov, AS & Grigoriev, SV 2019, 'Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments', Journal of Surface Investigation, Том. 13, № 4, стр. 567-569. https://doi.org/10.1134/S1027451019040165

APA

Tarnavich, V. V., Ukleev, V. A., Chernenkov, Y. P., Volegov, A. S., & Grigoriev, S. V. (2019). Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments. Journal of Surface Investigation, 13(4), 567-569. https://doi.org/10.1134/S1027451019040165

Vancouver

Tarnavich VV, Ukleev VA, Chernenkov YP, Volegov AS, Grigoriev SV. Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments. Journal of Surface Investigation. 2019 Июль 1;13(4):567-569. https://doi.org/10.1134/S1027451019040165

Author

Tarnavich, V. V. ; Ukleev, V. A. ; Chernenkov, Yu P. ; Volegov, A. S. ; Grigoriev, S. V. / Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments. в: Journal of Surface Investigation. 2019 ; Том 13, № 4. стр. 567-569.

BibTeX

@article{00e3dadb3ecb4e10ac29ba0806b353b4,
title = "Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments",
abstract = "Abstract: A magnetic cell with permanent magnets for the synchrotron-radiation diffraction study of small thin-film samples is calculated and the cell design is proposed. The cell induces magnetic fields up to 2 T at a gap between the pole tips of up to 4 mm. The external sizes of the magnetic cell are 110 × 70 × 45 mm, which makes it easy to fix it on a goniometric head. Test experiments are carried out on a Pilatus@SNBL diffractometer at the BM01A station of the Swiss–Norwegian beamlines of the European Synchrotron Radiation Facility.",
keywords = "magnetic field, magnetostriction, synchrotron radiation",
author = "Tarnavich, {V. V.} and Ukleev, {V. A.} and Chernenkov, {Yu P.} and Volegov, {A. S.} and Grigoriev, {S. V.}",
note = "Publisher Copyright: {\textcopyright} 2019, Pleiades Publishing, Ltd.",
year = "2019",
month = jul,
day = "1",
doi = "10.1134/S1027451019040165",
language = "English",
volume = "13",
pages = "567--569",
journal = "ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ",
issn = "1027-4510",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "4",

}

RIS

TY - JOUR

T1 - Compact Magnetic Cell with Permanent Magnets for X-Ray Diffraction Experiments

AU - Tarnavich, V. V.

AU - Ukleev, V. A.

AU - Chernenkov, Yu P.

AU - Volegov, A. S.

AU - Grigoriev, S. V.

N1 - Publisher Copyright: © 2019, Pleiades Publishing, Ltd.

PY - 2019/7/1

Y1 - 2019/7/1

N2 - Abstract: A magnetic cell with permanent magnets for the synchrotron-radiation diffraction study of small thin-film samples is calculated and the cell design is proposed. The cell induces magnetic fields up to 2 T at a gap between the pole tips of up to 4 mm. The external sizes of the magnetic cell are 110 × 70 × 45 mm, which makes it easy to fix it on a goniometric head. Test experiments are carried out on a Pilatus@SNBL diffractometer at the BM01A station of the Swiss–Norwegian beamlines of the European Synchrotron Radiation Facility.

AB - Abstract: A magnetic cell with permanent magnets for the synchrotron-radiation diffraction study of small thin-film samples is calculated and the cell design is proposed. The cell induces magnetic fields up to 2 T at a gap between the pole tips of up to 4 mm. The external sizes of the magnetic cell are 110 × 70 × 45 mm, which makes it easy to fix it on a goniometric head. Test experiments are carried out on a Pilatus@SNBL diffractometer at the BM01A station of the Swiss–Norwegian beamlines of the European Synchrotron Radiation Facility.

KW - magnetic field

KW - magnetostriction

KW - synchrotron radiation

UR - http://www.scopus.com/inward/record.url?scp=85071603625&partnerID=8YFLogxK

U2 - 10.1134/S1027451019040165

DO - 10.1134/S1027451019040165

M3 - Article

AN - SCOPUS:85071603625

VL - 13

SP - 567

EP - 569

JO - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

JF - ПОВЕРХНОСТЬ. РЕНТГЕНОВСКИЕ, СИНХРОТРОННЫЕ И НЕЙТРОННЫЕ ИССЛЕДОВАНИЯ

SN - 1027-4510

IS - 4

ER -

ID: 86426987