Standard

Bifunctional heater-thermometer Nd 3+ -doped nanoparticles with multiple temperature sensing parameters. / Kolesnikov, I.E.; Kalinichev, A.A.; Kurochkin, M.A.; Mamonova, D.V.; Kolesnikov, E.Y.; Lähderanta, E.; Mikhailov, M.D.

в: Nanotechnology, Том 30, № 14, 145501, 05.04.2019, стр. 145501.

Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование

Harvard

APA

Vancouver

Author

Kolesnikov, I.E. ; Kalinichev, A.A. ; Kurochkin, M.A. ; Mamonova, D.V. ; Kolesnikov, E.Y. ; Lähderanta, E. ; Mikhailov, M.D. / Bifunctional heater-thermometer Nd 3+ -doped nanoparticles with multiple temperature sensing parameters. в: Nanotechnology. 2019 ; Том 30, № 14. стр. 145501.

BibTeX

@article{53bd497c3b1e4994bcbf55755f4122ed,
title = "Bifunctional heater-thermometer Nd 3+ -doped nanoparticles with multiple temperature sensing parameters",
abstract = "Achieving a combination of real-time diagnosis and therapy in a single platform with sensitive thermometry and efficient heat production is a crucial step towards controllable photothermal therapy. Here, Nd3+-doped Y2O3 nanoparticles prepared using the combined Pechini-foaming technique operating in the first and second biological windows were demonstrated as thermal sensors within the wide temperature range of 123-873 K, and as heaters with a temperature increase of 100 K. Thermal sensing was performed based on various approaches: luminescence intensity ratio (electronic levels; Stark sublevels), spectral line position and line bandwidth were used as temperature-dependent parameters. The applicability of these sensing parameters, along with relative thermal sensitivity and temperature resolution, are discussed and compared. The influence of Nd3+-doping concentration on thermometer and heater efficiency was also investigated.",
keywords = "Nd, biological window, hyperthermia, luminescence, nanosensor, thermometry, Nd3+, SHARP EMISSION-LINES, THERMAL SENSITIVITY, GARNET, ND3+, SHIFTS, TRANSITION, LUMINESCENCE, LANTHANIDE, NANOTHERMOMETERS, STARK ENERGY-LEVELS",
author = "I.E. Kolesnikov and A.A. Kalinichev and M.A. Kurochkin and D.V. Mamonova and E.Y. Kolesnikov and E. L{\"a}hderanta and M.D. Mikhailov",
note = "cited By 0",
year = "2019",
month = apr,
day = "5",
doi = "10.1088/1361-6528/aafcb8",
language = "English",
volume = "30",
pages = "145501",
journal = "Nanotechnology",
issn = "0957-4484",
publisher = "IOP Publishing Ltd.",
number = "14",

}

RIS

TY - JOUR

T1 - Bifunctional heater-thermometer Nd 3+ -doped nanoparticles with multiple temperature sensing parameters

AU - Kolesnikov, I.E.

AU - Kalinichev, A.A.

AU - Kurochkin, M.A.

AU - Mamonova, D.V.

AU - Kolesnikov, E.Y.

AU - Lähderanta, E.

AU - Mikhailov, M.D.

N1 - cited By 0

PY - 2019/4/5

Y1 - 2019/4/5

N2 - Achieving a combination of real-time diagnosis and therapy in a single platform with sensitive thermometry and efficient heat production is a crucial step towards controllable photothermal therapy. Here, Nd3+-doped Y2O3 nanoparticles prepared using the combined Pechini-foaming technique operating in the first and second biological windows were demonstrated as thermal sensors within the wide temperature range of 123-873 K, and as heaters with a temperature increase of 100 K. Thermal sensing was performed based on various approaches: luminescence intensity ratio (electronic levels; Stark sublevels), spectral line position and line bandwidth were used as temperature-dependent parameters. The applicability of these sensing parameters, along with relative thermal sensitivity and temperature resolution, are discussed and compared. The influence of Nd3+-doping concentration on thermometer and heater efficiency was also investigated.

AB - Achieving a combination of real-time diagnosis and therapy in a single platform with sensitive thermometry and efficient heat production is a crucial step towards controllable photothermal therapy. Here, Nd3+-doped Y2O3 nanoparticles prepared using the combined Pechini-foaming technique operating in the first and second biological windows were demonstrated as thermal sensors within the wide temperature range of 123-873 K, and as heaters with a temperature increase of 100 K. Thermal sensing was performed based on various approaches: luminescence intensity ratio (electronic levels; Stark sublevels), spectral line position and line bandwidth were used as temperature-dependent parameters. The applicability of these sensing parameters, along with relative thermal sensitivity and temperature resolution, are discussed and compared. The influence of Nd3+-doping concentration on thermometer and heater efficiency was also investigated.

KW - Nd

KW - biological window

KW - hyperthermia

KW - luminescence

KW - nanosensor

KW - thermometry

KW - Nd3+

KW - SHARP EMISSION-LINES

KW - THERMAL SENSITIVITY

KW - GARNET

KW - ND3+

KW - SHIFTS

KW - TRANSITION

KW - LUMINESCENCE

KW - LANTHANIDE

KW - NANOTHERMOMETERS

KW - STARK ENERGY-LEVELS

UR - http://www.scopus.com/inward/record.url?scp=85061275035&partnerID=8YFLogxK

UR - http://www.mendeley.com/research/bifunctional-heaterthermometer-nd3doped-nanoparticles-multiple-temperature-sensing-parameters

U2 - 10.1088/1361-6528/aafcb8

DO - 10.1088/1361-6528/aafcb8

M3 - Article

C2 - 30625447

VL - 30

SP - 145501

JO - Nanotechnology

JF - Nanotechnology

SN - 0957-4484

IS - 14

M1 - 145501

ER -

ID: 38681172