Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
A rotating cotton‐based disk packed with a cation-exchange resin : Separation of ofloxacin from biological fluids followed by chemiluminescence determination. / Vakh, Christina ; Alaboud, Marcel ; Lebedinets, Sofya ; Bulatov, Andrey .
в: Talanta, Том 196, 2019, стр. 117-123.Результаты исследований: Научные публикации в периодических изданиях › статья › Рецензирование
}
TY - JOUR
T1 - A rotating cotton‐based disk packed with a cation-exchange resin
T2 - Separation of ofloxacin from biological fluids followed by chemiluminescence determination
AU - Vakh, Christina
AU - Alaboud, Marcel
AU - Lebedinets, Sofya
AU - Bulatov, Andrey
PY - 2019
Y1 - 2019
N2 - A novel approach for green and simple solid-phase extraction of ionizable analytes using cation-exchange resin particles packed in a rotating cotton‐based disk has been developed and utilized for the chemiluminescence determination of ofloxacin in biological fluids (serum and urine). The use of highly-available cation-exchange resin provided effective separation of analyte from complex sample matrixes and its elution by aqueous electrolyte solution without any organic solvents. Ofloxacin ionization in acidic sample solution allowed to provide effective separation of the analyte for subsequent chemiluminescence detection. The cotton‐based disk was characterized by effective wettability. This feature promoted high mass transfer of the analyte to the cation-exchange resin surface at separation step and into elution solution at elution step. The sorption time was decreased to 10 min while the elution time was 5 min. Under the optimal conditions, the detector response for ofloxacin was linear in the concentration range from 9 × 10 −8 to 3 × 10 −5 mol L −1. The limit of detection, calculated from a blank test based on 3σ was 3 × 10 −8 mol L −1.
AB - A novel approach for green and simple solid-phase extraction of ionizable analytes using cation-exchange resin particles packed in a rotating cotton‐based disk has been developed and utilized for the chemiluminescence determination of ofloxacin in biological fluids (serum and urine). The use of highly-available cation-exchange resin provided effective separation of analyte from complex sample matrixes and its elution by aqueous electrolyte solution without any organic solvents. Ofloxacin ionization in acidic sample solution allowed to provide effective separation of the analyte for subsequent chemiluminescence detection. The cotton‐based disk was characterized by effective wettability. This feature promoted high mass transfer of the analyte to the cation-exchange resin surface at separation step and into elution solution at elution step. The sorption time was decreased to 10 min while the elution time was 5 min. Under the optimal conditions, the detector response for ofloxacin was linear in the concentration range from 9 × 10 −8 to 3 × 10 −5 mol L −1. The limit of detection, calculated from a blank test based on 3σ was 3 × 10 −8 mol L −1.
KW - Cation-exchange resin
KW - Chemiluminescence
KW - Ofloxacin
KW - Rotating cotton-based disk
KW - Rotating-disk sorptive extraction
KW - Serum
KW - Solid-phase extraction
KW - Urine
U2 - 10.1016/j.talanta.2018.12.024
DO - 10.1016/j.talanta.2018.12.024
M3 - Article
VL - 196
SP - 117
EP - 123
JO - Talanta
JF - Talanta
SN - 0039-9140
ER -