abstract = "An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol – N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10−8·mol L−1 (0.01 mg kg−1) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples.",
keywords = "Chemiluminescence, Flow analysis, Gas-diffusion, Phenols, Screening, Smoked food, Ultrasound assisted solid-liquid extraction, -",
author = "Christina Vakh and Ekaterina Evdokimova and Aleksei Pochivalov and Leonid Moskvin and Andrey Bulatov",
note = "-",
year = "2017",
month = dec,
day = "15",
doi = "10.1016/j.foodchem.2017.06.049",
language = "English",
volume = "237",
pages = "929--935",
journal = "Food Chemistry",
issn = "0308-8146",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples

T2 - -

AU - Vakh, Christina

AU - Evdokimova, Ekaterina

AU - Pochivalov, Aleksei

AU - Moskvin, Leonid

AU - Bulatov, Andrey

N1 - -

PY - 2017/12/15

Y1 - 2017/12/15

N2 - An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol – N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10−8·mol L−1 (0.01 mg kg−1) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples.

AB - An easily performed fully automated and miniaturized flow injection chemiluminescence (CL) method for determination of phenols in smoked food samples has been proposed. This method includes the ultrasound assisted solid-liquid extraction coupled with gas-diffusion separation of phenols from smoked food sample and analytes absorption into a NaOH solution in a specially designed gas-diffusion cell. The flow system was designed to focus on automation and miniaturization with minimal sample and reagent consumption by inexpensive instrumentation. The luminol – N-bromosuccinimide system in an alkaline medium was used for the CL determination of phenols. The limit of detection of the proposed procedure was 3·10−8·mol L−1 (0.01 mg kg−1) in terms of phenol. The presented method demonstrated to be a good tool for easy, rapid and cost-effective point-of-need screening phenols in smoked food samples.

KW - Chemiluminescence

KW - Flow analysis

KW - Gas-diffusion

KW - Phenols

KW - Screening

KW - Smoked food

KW - Ultrasound assisted solid-liquid extraction

KW - -

UR - http://www.scopus.com/inward/record.url?scp=85020693126&partnerID=8YFLogxK

U2 - 10.1016/j.foodchem.2017.06.049

DO - 10.1016/j.foodchem.2017.06.049

M3 - Article

C2 - 28764088

AN - SCOPUS:85020693126

VL - 237

SP - 929

EP - 935

JO - Food Chemistry

JF - Food Chemistry

SN - 0308-8146

ER -