Экспериментальное обоснование безопасности применения электронного экстрактора. / Пую, Д.А.; Соколович, Н.А.; Соловьева, Т.С.

в: Медицинский альянс, № 1, 2018, стр. 79-83.

Результаты исследований: Научные публикации в периодических изданияхстатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{73e1239c63c44cc7bea65ea06583b83f,
title = "Экспериментальное обоснование безопасности применения электронного экстрактора",
abstract = "Currently, there is rapid development of technology in all branches of science, including in dentistry. The intro- duction of new instruments is not possible without prior proof of their safety in experimental research. In this arti- cle, we study the impact of electric extractor on the rat{\textquoteright}s periodontal tissues to confirm the safety of this device in case of its use for removing fragments of endodontic instruments from the tooth root canal. In the course of work the authors conducted histological analysis of the mandible of rats in the field of application of the stud- ied device. The result is a conclusion about the safety of using electronic extractor to periodontal tissues and makes recommendations about its implementation in clinical practice.",
keywords = "ТКАНИ ПЕРИОДОНТА, ГИСТОЛОГИЧЕСКОЕ ИССЛЕДОВАНИЕ, НИЖНЯЯ ЧЕЛЮСТЬ КРЫС, ЭЛЕКТРОННЫЙ ЭКСТРАКТОР, ОТЛОМОК ЭНДОДОНТИЧЕСКОГО ИНСТРУМЕНТА, PERIODONTAL TISSUE, Histological analysis, MANDIBLE OF RATS, ELECTRONIC EXTRACTOR, FRAGMENT OF ENDO- DONTIC INSTRUMENT",
author = "Д.А. Пую and Н.А. Соколович and Т.С. Соловьева",
note = "ISSN 2307-6348",
year = "2018",
language = "русский",
pages = "79--83",
journal = "Медицинский альянс",
issn = "2307-6348",
publisher = "Национальная Ассоциация Фтизиатров",
number = "1",

}

RIS

TY - JOUR

T1 - Экспериментальное обоснование безопасности применения электронного экстрактора

AU - Пую, Д.А.

AU - Соколович, Н.А.

AU - Соловьева, Т.С.

N1 - ISSN 2307-6348

PY - 2018

Y1 - 2018

N2 - Currently, there is rapid development of technology in all branches of science, including in dentistry. The intro- duction of new instruments is not possible without prior proof of their safety in experimental research. In this arti- cle, we study the impact of electric extractor on the rat’s periodontal tissues to confirm the safety of this device in case of its use for removing fragments of endodontic instruments from the tooth root canal. In the course of work the authors conducted histological analysis of the mandible of rats in the field of application of the stud- ied device. The result is a conclusion about the safety of using electronic extractor to periodontal tissues and makes recommendations about its implementation in clinical practice.

AB - Currently, there is rapid development of technology in all branches of science, including in dentistry. The intro- duction of new instruments is not possible without prior proof of their safety in experimental research. In this arti- cle, we study the impact of electric extractor on the rat’s periodontal tissues to confirm the safety of this device in case of its use for removing fragments of endodontic instruments from the tooth root canal. In the course of work the authors conducted histological analysis of the mandible of rats in the field of application of the stud- ied device. The result is a conclusion about the safety of using electronic extractor to periodontal tissues and makes recommendations about its implementation in clinical practice.

KW - ТКАНИ ПЕРИОДОНТА

KW - ГИСТОЛОГИЧЕСКОЕ ИССЛЕДОВАНИЕ

KW - НИЖНЯЯ ЧЕЛЮСТЬ КРЫС

KW - ЭЛЕКТРОННЫЙ ЭКСТРАКТОР

KW - ОТЛОМОК ЭНДОДОНТИЧЕСКОГО ИНСТРУМЕНТА

KW - PERIODONTAL TISSUE

KW - Histological analysis

KW - MANDIBLE OF RATS

KW - ELECTRONIC EXTRACTOR

KW - FRAGMENT OF ENDO- DONTIC INSTRUMENT

UR - http://www.med-alyans.ru/index.php/Hahn/article/view/146/738