Standard

The technology of punctional cryoablation of malignant breast tumors. / Belyaev, A. M.; Prokhorov, G. G.; Kryvorotko, P. V.; Busko, E. A.; Zakharova, V. D.; Petrik, S. V.; Frolov, O. N.

In: Voprosy Onkologii, Vol. 66, No. 4, 2020, p. 346-352.

Research output: Contribution to journalReview articlepeer-review

Harvard

Belyaev, AM, Prokhorov, GG, Kryvorotko, PV, Busko, EA, Zakharova, VD, Petrik, SV & Frolov, ON 2020, 'The technology of punctional cryoablation of malignant breast tumors', Voprosy Onkologii, vol. 66, no. 4, pp. 346-352. https://doi.org/10.37469/0507-3758-2020-66-4-346-352

APA

Belyaev, A. M., Prokhorov, G. G., Kryvorotko, P. V., Busko, E. A., Zakharova, V. D., Petrik, S. V., & Frolov, O. N. (2020). The technology of punctional cryoablation of malignant breast tumors. Voprosy Onkologii, 66(4), 346-352. https://doi.org/10.37469/0507-3758-2020-66-4-346-352

Vancouver

Belyaev AM, Prokhorov GG, Kryvorotko PV, Busko EA, Zakharova VD, Petrik SV et al. The technology of punctional cryoablation of malignant breast tumors. Voprosy Onkologii. 2020;66(4):346-352. https://doi.org/10.37469/0507-3758-2020-66-4-346-352

Author

Belyaev, A. M. ; Prokhorov, G. G. ; Kryvorotko, P. V. ; Busko, E. A. ; Zakharova, V. D. ; Petrik, S. V. ; Frolov, O. N. / The technology of punctional cryoablation of malignant breast tumors. In: Voprosy Onkologii. 2020 ; Vol. 66, No. 4. pp. 346-352.

BibTeX

@article{7e4fda855d3549a09f6218646e11e415,
title = "The technology of punctional cryoablation of malignant breast tumors",
abstract = "The cryoablation of malignant breast tumors technology with the use of modern miniinvasivc equipment based on liquid nitrogen is represented. Navigation method, monitoring and postoperative observation of patients arc presented in detail. In clinical cases, where surgical operation alternatives can be considered, indications to cryoablation are: Elderly patients and slow growth of tumor; enough distance from the skin; precise ultrasound visualization of tumor borders; limited lesion size, which allow icy front to fully cover the tumor; specialized oncological center conditions; navigational and miniinvasive cryogenic equipment availability; additional special training for oncologists; careful psychological training for patients and their relatives; informed consent formalization by patient and her refusal of standard treatment. Procedure starts with trepan-biopsy to get the material for immunohistochemical investigations. The first probe is installed paratumorally in the deepest point and its cryofixation in tissues is performed without large glaciation zone formed. After that other probes and injectional microthermocouples are installed in tumor's outline, then cooling is started. Capture of healthy tissues must be 1 sm with exposition retention during 10 minutes and passive warming during 10-15 minutes. Second cooling is obligatorily in the same probes' position and in the same time-intervals. All the common rules of diagnostics and complex treatment are preserved. The clinical case of successful cryoablation is presented. ,.",
keywords = "Breast cancer, Cryoablation, Cryosurgery, Cryotherapy, Minimally invasive methods",
author = "Belyaev, {A. M.} and Prokhorov, {G. G.} and Kryvorotko, {P. V.} and Busko, {E. A.} and Zakharova, {V. D.} and Petrik, {S. V.} and Frolov, {O. N.}",
note = "Publisher Copyright: {\textcopyright} 2020 Izdatel'stvo Meditsina. All rights reserved.",
year = "2020",
doi = "10.37469/0507-3758-2020-66-4-346-352",
language = "English",
volume = "66",
pages = "346--352",
journal = "Вопросы онкологии",
issn = "0507-3758",
publisher = "Медицина",
number = "4",

}

RIS

TY - JOUR

T1 - The technology of punctional cryoablation of malignant breast tumors

AU - Belyaev, A. M.

AU - Prokhorov, G. G.

AU - Kryvorotko, P. V.

AU - Busko, E. A.

AU - Zakharova, V. D.

AU - Petrik, S. V.

AU - Frolov, O. N.

N1 - Publisher Copyright: © 2020 Izdatel'stvo Meditsina. All rights reserved.

PY - 2020

Y1 - 2020

N2 - The cryoablation of malignant breast tumors technology with the use of modern miniinvasivc equipment based on liquid nitrogen is represented. Navigation method, monitoring and postoperative observation of patients arc presented in detail. In clinical cases, where surgical operation alternatives can be considered, indications to cryoablation are: Elderly patients and slow growth of tumor; enough distance from the skin; precise ultrasound visualization of tumor borders; limited lesion size, which allow icy front to fully cover the tumor; specialized oncological center conditions; navigational and miniinvasive cryogenic equipment availability; additional special training for oncologists; careful psychological training for patients and their relatives; informed consent formalization by patient and her refusal of standard treatment. Procedure starts with trepan-biopsy to get the material for immunohistochemical investigations. The first probe is installed paratumorally in the deepest point and its cryofixation in tissues is performed without large glaciation zone formed. After that other probes and injectional microthermocouples are installed in tumor's outline, then cooling is started. Capture of healthy tissues must be 1 sm with exposition retention during 10 minutes and passive warming during 10-15 minutes. Second cooling is obligatorily in the same probes' position and in the same time-intervals. All the common rules of diagnostics and complex treatment are preserved. The clinical case of successful cryoablation is presented. ,.

AB - The cryoablation of malignant breast tumors technology with the use of modern miniinvasivc equipment based on liquid nitrogen is represented. Navigation method, monitoring and postoperative observation of patients arc presented in detail. In clinical cases, where surgical operation alternatives can be considered, indications to cryoablation are: Elderly patients and slow growth of tumor; enough distance from the skin; precise ultrasound visualization of tumor borders; limited lesion size, which allow icy front to fully cover the tumor; specialized oncological center conditions; navigational and miniinvasive cryogenic equipment availability; additional special training for oncologists; careful psychological training for patients and their relatives; informed consent formalization by patient and her refusal of standard treatment. Procedure starts with trepan-biopsy to get the material for immunohistochemical investigations. The first probe is installed paratumorally in the deepest point and its cryofixation in tissues is performed without large glaciation zone formed. After that other probes and injectional microthermocouples are installed in tumor's outline, then cooling is started. Capture of healthy tissues must be 1 sm with exposition retention during 10 minutes and passive warming during 10-15 minutes. Second cooling is obligatorily in the same probes' position and in the same time-intervals. All the common rules of diagnostics and complex treatment are preserved. The clinical case of successful cryoablation is presented. ,.

KW - Breast cancer

KW - Cryoablation

KW - Cryosurgery

KW - Cryotherapy

KW - Minimally invasive methods

UR - http://www.scopus.com/inward/record.url?scp=85098237267&partnerID=8YFLogxK

U2 - 10.37469/0507-3758-2020-66-4-346-352

DO - 10.37469/0507-3758-2020-66-4-346-352

M3 - Review article

AN - SCOPUS:85098237267

VL - 66

SP - 346

EP - 352

JO - Вопросы онкологии

JF - Вопросы онкологии

SN - 0507-3758

IS - 4

ER -

ID: 86215386