Standard

The Pul-3 catalogue of 58483 stars in the Tycho-2 system. / Khrutskaya, E. V.; Khovritchev, M. Yu; Bronnikova, N. M.

In: Astronomy and Astrophysics, Vol. 418, No. 1, 04.2004, p. 357-362.

Research output: Contribution to journalArticlepeer-review

Harvard

Khrutskaya, EV, Khovritchev, MY & Bronnikova, NM 2004, 'The Pul-3 catalogue of 58483 stars in the Tycho-2 system', Astronomy and Astrophysics, vol. 418, no. 1, pp. 357-362. https://doi.org/10.1051/0004-6361:20034232

APA

Khrutskaya, E. V., Khovritchev, M. Y., & Bronnikova, N. M. (2004). The Pul-3 catalogue of 58483 stars in the Tycho-2 system. Astronomy and Astrophysics, 418(1), 357-362. https://doi.org/10.1051/0004-6361:20034232

Vancouver

Khrutskaya EV, Khovritchev MY, Bronnikova NM. The Pul-3 catalogue of 58483 stars in the Tycho-2 system. Astronomy and Astrophysics. 2004 Apr;418(1):357-362. https://doi.org/10.1051/0004-6361:20034232

Author

Khrutskaya, E. V. ; Khovritchev, M. Yu ; Bronnikova, N. M. / The Pul-3 catalogue of 58483 stars in the Tycho-2 system. In: Astronomy and Astrophysics. 2004 ; Vol. 418, No. 1. pp. 357-362.

BibTeX

@article{06b20cd8bc2b49a1a143d766d8f86ac4,
title = "The Pul-3 catalogue of 58483 stars in the Tycho-2 system",
abstract = "A catalogue of positions and proper motions of 58483 stars (Pul-3) has been constructed at the Pulkovo observatory. The Pul-3 is based on the results of measurements of photographic plates with galaxies (Deutsch's plan). All plates were taken using the Pulkovo Normal Astrograph (the first epoch is in the 1950s and the second epoch is in the 1970s). The Pul-3 catalogue contains stars of mainly 12 to 16.5 mag in 146 fields with galaxies in the declination zone from -5° to +85°. The Tycho-2 has been used as a reference catalogue. The mean epoch of the Pul-3 is 1963.25. The internal positional accuracy of the Pul-3 catalogue at the mean epoch of observations is ±80 mas. The accuracy of the proper motions is mostly within ±3 mas/yr to ±12 mas/yr. Comparisons of the Pul-3 with Tycho-2 and ARIHIP have been done at the mean epoch of the Pul-3. The Pul-3 external positional accuracy relative to Tycho-2 is ±150 mas.",
keywords = "Astrometry, Catalogs",
author = "Khrutskaya, {E. V.} and Khovritchev, {M. Yu} and Bronnikova, {N. M.}",
note = "Copyright: Copyright 2008 Elsevier B.V., All rights reserved.",
year = "2004",
month = apr,
doi = "10.1051/0004-6361:20034232",
language = "English",
volume = "418",
pages = "357--362",
journal = "ASTRONOMY & ASTROPHYSICS",
issn = "0004-6361",
publisher = "EDP Sciences",
number = "1",

}

RIS

TY - JOUR

T1 - The Pul-3 catalogue of 58483 stars in the Tycho-2 system

AU - Khrutskaya, E. V.

AU - Khovritchev, M. Yu

AU - Bronnikova, N. M.

N1 - Copyright: Copyright 2008 Elsevier B.V., All rights reserved.

PY - 2004/4

Y1 - 2004/4

N2 - A catalogue of positions and proper motions of 58483 stars (Pul-3) has been constructed at the Pulkovo observatory. The Pul-3 is based on the results of measurements of photographic plates with galaxies (Deutsch's plan). All plates were taken using the Pulkovo Normal Astrograph (the first epoch is in the 1950s and the second epoch is in the 1970s). The Pul-3 catalogue contains stars of mainly 12 to 16.5 mag in 146 fields with galaxies in the declination zone from -5° to +85°. The Tycho-2 has been used as a reference catalogue. The mean epoch of the Pul-3 is 1963.25. The internal positional accuracy of the Pul-3 catalogue at the mean epoch of observations is ±80 mas. The accuracy of the proper motions is mostly within ±3 mas/yr to ±12 mas/yr. Comparisons of the Pul-3 with Tycho-2 and ARIHIP have been done at the mean epoch of the Pul-3. The Pul-3 external positional accuracy relative to Tycho-2 is ±150 mas.

AB - A catalogue of positions and proper motions of 58483 stars (Pul-3) has been constructed at the Pulkovo observatory. The Pul-3 is based on the results of measurements of photographic plates with galaxies (Deutsch's plan). All plates were taken using the Pulkovo Normal Astrograph (the first epoch is in the 1950s and the second epoch is in the 1970s). The Pul-3 catalogue contains stars of mainly 12 to 16.5 mag in 146 fields with galaxies in the declination zone from -5° to +85°. The Tycho-2 has been used as a reference catalogue. The mean epoch of the Pul-3 is 1963.25. The internal positional accuracy of the Pul-3 catalogue at the mean epoch of observations is ±80 mas. The accuracy of the proper motions is mostly within ±3 mas/yr to ±12 mas/yr. Comparisons of the Pul-3 with Tycho-2 and ARIHIP have been done at the mean epoch of the Pul-3. The Pul-3 external positional accuracy relative to Tycho-2 is ±150 mas.

KW - Astrometry

KW - Catalogs

UR - http://www.scopus.com/inward/record.url?scp=2342480532&partnerID=8YFLogxK

U2 - 10.1051/0004-6361:20034232

DO - 10.1051/0004-6361:20034232

M3 - Article

AN - SCOPUS:2342480532

VL - 418

SP - 357

EP - 362

JO - ASTRONOMY & ASTROPHYSICS

JF - ASTRONOMY & ASTROPHYSICS

SN - 0004-6361

IS - 1

ER -

ID: 75128927