Standard

Statistical impact assessment some parameters of eye apples on tonometric intra-eye pressure. / Kachanov, Andrey B.; Bauer, Svetlana M.; Voronkova, Eva B.; Kornikov, Vladimir V.; Zimin, Boris A.

In: Russian Journal of Biomechanics, Vol. 22, No. 4, 01.01.2018, p. 463-471.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Author

Kachanov, Andrey B. ; Bauer, Svetlana M. ; Voronkova, Eva B. ; Kornikov, Vladimir V. ; Zimin, Boris A. / Statistical impact assessment some parameters of eye apples on tonometric intra-eye pressure. In: Russian Journal of Biomechanics. 2018 ; Vol. 22, No. 4. pp. 463-471.

BibTeX

@article{bda8decbfe1041a48107667bcf1c7ffa,
title = "Statistical impact assessment some parameters of eye apples on tonometric intra-eye pressure",
abstract = "The purpose of this study is to estimate the impact of ocular parameters on tonometrically measured intraocular pressure using statistical analysis. Two different tonometers (the Maklakov applanational and pneumatonometer) are discussed. Intraocular pressure readings obtained by pneumatonometer are significantly correlated with central corneal thickness. Maklakov tonometer readings are more affected by corneal curvature and the length of the anterior-posterior axis of the eye then by central corneal thickness, whilst pneumatonometer measurements are not correlated with corneal curvature and the anterior-posterior axis length.",
keywords = "Central corneal thickness, Corneal curvature, Intraocular pressure, Pneumatonometer, The length of the anterior-posterior axis, The Maklakom applanational tonometer",
author = "Kachanov, {Andrey B.} and Bauer, {Svetlana M.} and Voronkova, {Eva B.} and Kornikov, {Vladimir V.} and Zimin, {Boris A.}",
year = "2018",
month = jan,
day = "1",
doi = "10.15593/RJBiomech/2018.4.08",
language = "English",
volume = "22",
pages = "463--471",
journal = "РОССИЙСКИЙ ЖУРНАЛ БИОМЕХАНИКИ",
issn = "1812-5123",
publisher = "Perm National Research Polytechnic University",
number = "4",

}

RIS

TY - JOUR

T1 - Statistical impact assessment some parameters of eye apples on tonometric intra-eye pressure

AU - Kachanov, Andrey B.

AU - Bauer, Svetlana M.

AU - Voronkova, Eva B.

AU - Kornikov, Vladimir V.

AU - Zimin, Boris A.

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The purpose of this study is to estimate the impact of ocular parameters on tonometrically measured intraocular pressure using statistical analysis. Two different tonometers (the Maklakov applanational and pneumatonometer) are discussed. Intraocular pressure readings obtained by pneumatonometer are significantly correlated with central corneal thickness. Maklakov tonometer readings are more affected by corneal curvature and the length of the anterior-posterior axis of the eye then by central corneal thickness, whilst pneumatonometer measurements are not correlated with corneal curvature and the anterior-posterior axis length.

AB - The purpose of this study is to estimate the impact of ocular parameters on tonometrically measured intraocular pressure using statistical analysis. Two different tonometers (the Maklakov applanational and pneumatonometer) are discussed. Intraocular pressure readings obtained by pneumatonometer are significantly correlated with central corneal thickness. Maklakov tonometer readings are more affected by corneal curvature and the length of the anterior-posterior axis of the eye then by central corneal thickness, whilst pneumatonometer measurements are not correlated with corneal curvature and the anterior-posterior axis length.

KW - Central corneal thickness

KW - Corneal curvature

KW - Intraocular pressure

KW - Pneumatonometer

KW - The length of the anterior-posterior axis

KW - The Maklakom applanational tonometer

UR - http://www.scopus.com/inward/record.url?scp=85059646535&partnerID=8YFLogxK

U2 - 10.15593/RJBiomech/2018.4.08

DO - 10.15593/RJBiomech/2018.4.08

M3 - Article

AN - SCOPUS:85059646535

VL - 22

SP - 463

EP - 471

JO - РОССИЙСКИЙ ЖУРНАЛ БИОМЕХАНИКИ

JF - РОССИЙСКИЙ ЖУРНАЛ БИОМЕХАНИКИ

SN - 1812-5123

IS - 4

ER -

ID: 37752386