This paper is devoted to investigations of copper ring samples loaded under high-strain-rate by magnetic pulse method. Three loading schemes are used to achieve strain rate up to 1000000 1/s. The temporal dependence of strength in wide range of time is presented. Microstructure investigations of fracture surface and cross-section under these loading conditions were carried out.

Original languageEnglish
Pages (from-to)1373-1377
Number of pages5
JournalProcedia Structural Integrity
Volume13
DOIs
StatePublished - 1 Jan 2018
Event22nd European Conference on Fracture, ECF 2018 - Belgrade, Serbia
Duration: 25 Aug 201826 Aug 2018

    Research areas

  • High-strain-rate loading, Magnetic pulse loading, Microstructure analysis, Ring samples

    Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Civil and Structural Engineering
  • Materials Science(all)

ID: 41869852