We report on results of efficiency tests for MIPs and timing resolution studies obtained with different layouts of micro-channel plate (MCP) detector prototypes at CERN PS test beams. The detector is composed of an MCP stack and multipad readout anodes integrated with a passive isochronal summator. Several types of setups were tested, including MCPs with different gain. Also, a very first test of the Micro Sphere Plates detector was performed. The performance of fast electronics including Double Threshold Discriminators and a fast multiplicity discriminator for short 2 ns signals was studied. Currently, the best experimental results for MCP detectors show 75 ps timing resolution obtained at 75% efficiency for the registration of a single muon. We expect further enhancements, mostly through improvements in the fast electronics.

Original languageEnglish
Pages (from-to)220-224
Number of pages5
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume478
Issue number1-2
DOIs
StatePublished - 1 Feb 2002
Event9th International Conference on Instrumentation - Vienna, Austria
Duration: 19 Feb 200123 Feb 2001

    Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

ID: 88097771