Research output: Contribution to journal › Conference article › peer-review
We report on results of efficiency tests for MIPs and timing resolution studies obtained with different layouts of micro-channel plate (MCP) detector prototypes at CERN PS test beams. The detector is composed of an MCP stack and multipad readout anodes integrated with a passive isochronal summator. Several types of setups were tested, including MCPs with different gain. Also, a very first test of the Micro Sphere Plates detector was performed. The performance of fast electronics including Double Threshold Discriminators and a fast multiplicity discriminator for short 2 ns signals was studied. Currently, the best experimental results for MCP detectors show 75 ps timing resolution obtained at 75% efficiency for the registration of a single muon. We expect further enhancements, mostly through improvements in the fast electronics.
Original language | English |
---|---|
Pages (from-to) | 220-224 |
Number of pages | 5 |
Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
Volume | 478 |
Issue number | 1-2 |
DOIs | |
State | Published - 1 Feb 2002 |
Event | 9th International Conference on Instrumentation - Vienna, Austria Duration: 19 Feb 2001 → 23 Feb 2001 |