Standard

Quantum magnetometer for stabilization of the neutron magnetic resonance. / Aleksandrov, E. B.; Balabas, M. V.; Dmitriev, S. P.; Dovator, N. A.; Ivanov, A. I.; Karuzin, M. I.; Kulyasov, V. N.; Pazgalev, A. S.; Serebrov, A. P.

In: Technical Physics Letters, Vol. 32, No. 7, 07.2006, p. 627-629.

Research output: Contribution to journalArticlepeer-review

Harvard

Aleksandrov, EB, Balabas, MV, Dmitriev, SP, Dovator, NA, Ivanov, AI, Karuzin, MI, Kulyasov, VN, Pazgalev, AS & Serebrov, AP 2006, 'Quantum magnetometer for stabilization of the neutron magnetic resonance', Technical Physics Letters, vol. 32, no. 7, pp. 627-629. https://doi.org/10.1134/S1063785006070236

APA

Aleksandrov, E. B., Balabas, M. V., Dmitriev, S. P., Dovator, N. A., Ivanov, A. I., Karuzin, M. I., Kulyasov, V. N., Pazgalev, A. S., & Serebrov, A. P. (2006). Quantum magnetometer for stabilization of the neutron magnetic resonance. Technical Physics Letters, 32(7), 627-629. https://doi.org/10.1134/S1063785006070236

Vancouver

Aleksandrov EB, Balabas MV, Dmitriev SP, Dovator NA, Ivanov AI, Karuzin MI et al. Quantum magnetometer for stabilization of the neutron magnetic resonance. Technical Physics Letters. 2006 Jul;32(7):627-629. https://doi.org/10.1134/S1063785006070236

Author

Aleksandrov, E. B. ; Balabas, M. V. ; Dmitriev, S. P. ; Dovator, N. A. ; Ivanov, A. I. ; Karuzin, M. I. ; Kulyasov, V. N. ; Pazgalev, A. S. ; Serebrov, A. P. / Quantum magnetometer for stabilization of the neutron magnetic resonance. In: Technical Physics Letters. 2006 ; Vol. 32, No. 7. pp. 627-629.

BibTeX

@article{d3df1a8caf674ee68cee17401b40a036,
title = "Quantum magnetometer for stabilization of the neutron magnetic resonance",
abstract = "The design of a quantum magnetometer on cesium vapor is described. The device is intended for stabilization of the neutron resonance in experiments devoted to the search for the electric dipole moment (EDM) of neutron. The choice of this magnetometer type is justified and its potential sensitivity is estimated.",
author = "Aleksandrov, {E. B.} and Balabas, {M. V.} and Dmitriev, {S. P.} and Dovator, {N. A.} and Ivanov, {A. I.} and Karuzin, {M. I.} and Kulyasov, {V. N.} and Pazgalev, {A. S.} and Serebrov, {A. P.}",
note = "Funding Information: Acknowledgments. This study was supported by the Russian Foundation for Basic Research (project nos. 04-02-17440 and 05-02-17826) and the Department of Physics of the Russian Academy of Sciences (Program “Optical Spectroscopy and Frequency Standards”). Copyright: Copyright 2006 Elsevier B.V., All rights reserved.",
year = "2006",
month = jul,
doi = "10.1134/S1063785006070236",
language = "English",
volume = "32",
pages = "627--629",
journal = "Technical Physics Letters",
issn = "1063-7850",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "7",

}

RIS

TY - JOUR

T1 - Quantum magnetometer for stabilization of the neutron magnetic resonance

AU - Aleksandrov, E. B.

AU - Balabas, M. V.

AU - Dmitriev, S. P.

AU - Dovator, N. A.

AU - Ivanov, A. I.

AU - Karuzin, M. I.

AU - Kulyasov, V. N.

AU - Pazgalev, A. S.

AU - Serebrov, A. P.

N1 - Funding Information: Acknowledgments. This study was supported by the Russian Foundation for Basic Research (project nos. 04-02-17440 and 05-02-17826) and the Department of Physics of the Russian Academy of Sciences (Program “Optical Spectroscopy and Frequency Standards”). Copyright: Copyright 2006 Elsevier B.V., All rights reserved.

PY - 2006/7

Y1 - 2006/7

N2 - The design of a quantum magnetometer on cesium vapor is described. The device is intended for stabilization of the neutron resonance in experiments devoted to the search for the electric dipole moment (EDM) of neutron. The choice of this magnetometer type is justified and its potential sensitivity is estimated.

AB - The design of a quantum magnetometer on cesium vapor is described. The device is intended for stabilization of the neutron resonance in experiments devoted to the search for the electric dipole moment (EDM) of neutron. The choice of this magnetometer type is justified and its potential sensitivity is estimated.

UR - http://www.scopus.com/inward/record.url?scp=33748291687&partnerID=8YFLogxK

U2 - 10.1134/S1063785006070236

DO - 10.1134/S1063785006070236

M3 - Article

AN - SCOPUS:33748291687

VL - 32

SP - 627

EP - 629

JO - Technical Physics Letters

JF - Technical Physics Letters

SN - 1063-7850

IS - 7

ER -

ID: 74227439